{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.42,"lon":-80.87,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Bristol Township | |
Operator Name: VANGUARD OIL & GAS LLC | |
Well Pad ID: | |
Farm/Lease Name: JEWELL | |
License Status: Producing | |
License Date: 1979-12-12 | |
Spud Date: 1980-08-26 | |
Spud Drilling Contractor: | |
Final Drill Date: 1980-09-03 | |
Well Total Depth: 4050.00 ft | |
Configuration: Vertical | |
Latitude: 41.420000 | |
Longitude: -80.870000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1980-08-26 | R.I. 8-14-80 |
Completed | 1980-09-03 | R.I. 8-14-80 |
Reached Total Depth | 1980-09-03 | R.I. 8-14-80 |
Change of Owner | 2001-04-05 | Operator changed from 457, ALSID OIL & GAS to 6970, VANGUARD OIL & GAS LLC |
Record Last Modified | 2019-06-14 | R.I. 8-14-80 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 3836 | 3901 | 42 |
3836 | 3901 | 42 | |
3836 | 3901 | 42 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1750 Bbl | 30000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | ALSID OIL & GAS | 0.00 | 4982.00 | 365 |
1985 | ALSID OIL & GAS | 5025.00 | 806.00 | 0 |
1986 | ALSID OIL & GAS | 2224.00 | 374.00 | 365 |
1987 | ALSID OIL & GAS | 1672.00 | 289.00 | 365 |
1989 | ALSID OIL & GAS | 534.00 | 290.00 | 365 |
1990 | ALSID OIL & GAS | 698.00 | 301.00 | 365 |
1991 | ALSID OIL & GAS | 889.00 | 219.00 | 365 |
1992 | ALSID OIL & GAS | 1033.00 | 246.00 | 365 |
1993 | ALSID OIL & GAS | 519.00 | 243.00 | 365 |
1994 | ALSID OIL & GAS | 891.00 | 236.00 | 337 |
1997 | ALSID OIL & GAS | 673.00 | 192.00 | 365 |
1998 | ALSID OIL & GAS | 670.00 | 212.00 | 365 |
1999 | ALSID OIL & GAS | 588.00 | 205.00 | 365 |
2000 | VANGUARD OIL & GAS LLC | 676.00 | 153.00 | 365 |
2001 | VANGUARD OIL & GAS LLC | 626.00 | 144.00 | 365 |
2002 | VANGUARD OIL & GAS LLC | 586.00 | 204.00 | 365 |
2003 | VANGUARD OIL & GAS LLC | 556.00 | 134.00 | 365 |
2004 | VANGUARD OIL & GAS LLC | 587.00 | 126.00 | 365 |
2005 | VANGUARD OIL & GAS LLC | 558.00 | 153.00 | 365 |
2007 | VANGUARD OIL & GAS LLC | 422.00 | 105.00 | 365 |
2008 | VANGUARD OIL & GAS LLC | 418.00 | 145.00 | 365 |
2009 | VANGUARD OIL & GAS LLC | 163.00 | 79.00 | 365 |
2010 | VANGUARD OIL & GAS LLC | 496.00 | 144.00 | 365 |
2011 | VANGUARD OIL & GAS LLC | 521.00 | 141.00 | 0 |
2012 | VANGUARD OIL & GAS LLC | 626.00 | 142.00 | 366 |
2013 | VANGUARD OIL & GAS LLC | 1253.00 | 257.00 | 365 |
2014 | VANGUARD OIL & GAS LLC | 462.00 | 101.00 | 365 |
2015 | VANGUARD OIL & GAS LLC | 418.00 | 132.00 | 365 |
2016 | VANGUARD OIL & GAS LLC | 396.00 | 113.00 | 365 |
2017 | VANGUARD OIL & GAS LLC | 280.00 | 53.00 | 365 |
2018 | VANGUARD OIL & GAS LLC | 52.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | ALSID OIL & GAS | Brine | 0 | 365 |
1985 | ALSID OIL & GAS | Brine | 946 | 0 |
1986 | ALSID OIL & GAS | Brine | 363 | 365 |
1987 | ALSID OIL & GAS | Brine | 310 | 365 |
1989 | ALSID OIL & GAS | Brine | 434 | 365 |
1990 | ALSID OIL & GAS | Brine | 294 | 365 |
1991 | ALSID OIL & GAS | Brine | 233 | 365 |
1992 | ALSID OIL & GAS | Brine | 195 | 365 |
1993 | ALSID OIL & GAS | Brine | 322 | 365 |
1994 | ALSID OIL & GAS | Brine | 279 | 337 |
1997 | ALSID OIL & GAS | Brine | 269 | 365 |
1998 | ALSID OIL & GAS | Brine | 261 | 365 |
1999 | ALSID OIL & GAS | Brine | 259 | 365 |
2000 | VANGUARD OIL & GAS LLC | Brine | 242 | 365 |
2001 | VANGUARD OIL & GAS LLC | Brine | 345 | 365 |
2002 | VANGUARD OIL & GAS LLC | Brine | 232 | 365 |
2003 | VANGUARD OIL & GAS LLC | Brine | 211 | 365 |
2004 | VANGUARD OIL & GAS LLC | Brine | 164 | 365 |
2005 | VANGUARD OIL & GAS LLC | Brine | 142 | 365 |
2007 | VANGUARD OIL & GAS LLC | Brine | 171 | 365 |
2008 | VANGUARD OIL & GAS LLC | Brine | 197 | 365 |
2009 | VANGUARD OIL & GAS LLC | Brine | 178 | 365 |
2010 | VANGUARD OIL & GAS LLC | Brine | 107 | 365 |
2011 | VANGUARD OIL & GAS LLC | Brine | 183 | |
2012 | VANGUARD OIL & GAS LLC | Brine | 236 | 366 |
2013 | VANGUARD OIL & GAS LLC | Brine | 345 | 365 |
2014 | VANGUARD OIL & GAS LLC | Brine | 365 | |
2015 | VANGUARD OIL & GAS LLC | Brine | 0 | 365 |
2016 | VANGUARD OIL & GAS LLC | Brine | 210 | 365 |
2017 | VANGUARD OIL & GAS LLC | Brine | 22 | 365 |
2018 | VANGUARD OIL & GAS LLC | Brine | 34 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1214717768 | 2007-6-6 0:00:0 | PW | No Violations | |
-1242027247 | 2013-6-18 0:00: | PW | No Violations | 0.50 |
-829904518 | 2020-1-27 0:00: | PW | No Violations | 0.40 |
-974777826 | 2017-3-29 0:00: | PW | No Violations | 0.60 |
0774911466 | 2012-09-06 | Production Wells | No Violations | I conducted a production well inspection status check. My inspection found the well equipped with a pumping unit that was in good condition. The tank battery contained one 100 barrel oil storage tank, one buried brine storage tank, a separator. The identification sign had the wrong information and the entire diked area was overgrown with weeds. I called Russell, field supervisor for Vanguard Oil and Gas, at 330-506-8152, and asked him to install an identification sign with the correct information and to take care of the overgrown weeds. I will conduct a follow-up inspection by 9/14/2012. This well shares a tank battery and lease road with permit number 2-1424. |
0822610242 | 2008-08-18 | Production Wells | No Violations | no violations . |
0974777826 | 2017-03-29 | Production Wells | No Violations
-26-17 is installed on the sales line after the separator. The pick-up line is secure with a plug. An identification sign is posted at the tank battery and well. The access road is in good repair. The tank battery is shared with permit #2-1424. The equipment on site:
| |
1214717768 | 2007-06-06 | Production Wells | No Violations | no violations . |
1242027247 | 2013-06-18 | Production Wells | No Violations | My inspection found a new dike built per my request. |
1392647553 | 2013-03-21 | Production Wells | No Violations | My inspection found the proper identification posted at the pumping unit and production tank. The weeds were cut down from inside and around the tank battery, which revealed a weathered dike not capable of containment requirements. I called the Vanguard Oil & Gas office at 330-223-1074. I instructed them to repair the weathered dike. |
1679138429 | 2019-02-08 | Production Wells | No Violations | I conducted an inspection on this well. At the time of this inspection, the well was equipped with a pumping unit and in production. The tank battery location was comprised of one 210 BBL tank, one 50 BBL steel tank and a mechanical separator. Valves on the separator were open and the chart on the sales line showed production. Legible identification was present at the well and tank battery. The diked tank battery was shared with well 2-1371. The lease access was stable. |
1701361790 | 2011-06-02 | Production Wells | No Violations | There were no violations found at the time. |
774911466 | 2012-9-6 0:00:0 | PW | No Violations | 1.00 |
822610242 | 2008-8-18 0:00: | PW | No Violations |