If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-21561 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.18,"lon":-80.79,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Weathersfield Township | |
Operator Name: RMI TITANIUM COMPANY | |
Well Pad ID: | |
Farm/Lease Name: GARLAND J & W | |
License Status: Producing | |
License Date: 1981-10-20 | |
Spud Date: 1981-11-24 | |
Spud Drilling Contractor: | |
Final Drill Date: 1981-12-02 | |
Well Total Depth: 4785.00 ft | |
Configuration: Vertical | |
Latitude: 41.180000 | |
Longitude: -80.790000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1981-10-20 | 2125 EASTERN PETROLEUM CO GeoDate 10/20/81 |
Oil and Gas | 1981-10-20 | Issued Date 10/20/81 Expired Date 10/20/82 Acres 0000000 Tool Type RTAF Proposed Formation Proposed Depth 00000 Proposed Drill Depth 00000 |
Original Spud | 1981-11-24 | |
Completed | 1981-12-02 | |
Reached Total Depth | 1981-12-02 | |
Completion Report Received | 1982-01-02 | |
Construction Permit Expires | 1982-10-20 | |
CO | 1996-10-03 | 213 LOMAK OPERATING CO GeoDate 10/20/81 |
Change of Owner | 2000-06-28 | Operator changed from 213, RANGE OPERATING COMPANY to 6674, GREAT LAKES ENERGY PTNSHP LLC |
Change of Owner | 2000-07-06 | Operator changed from 6674, GREAT LAKES ENERGY PTNSHP LLC to 6786, RMI TITANIUM COMPANY |
Record Last Modified | 2013-10-03 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 4556 | 4666 | 22 |
4556 | 4666 | 22 | |
4556 | 4666 | 22 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 90000 Gal | 60000 | |||
N2 | 0 | 218 Mscf | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | RMI COMPANY | 17515.00 | 932.00 | 0 |
2000 | RMI TITANIUM COMPANY | 4192.00 | 48.00 | 365 |
2001 | RMI TITANIUM COMPANY | 3509.00 | 33.00 | 365 |
2002 | RMI TITANIUM COMPANY | 4020.00 | 49.00 | 365 |
2003 | RMI TITANIUM COMPANY | 4182.00 | 0.00 | 365 |
2004 | RMI TITANIUM COMPANY | 3987.00 | 57.00 | 365 |
2005 | RMI TITANIUM COMPANY | 4053.00 | 0.00 | 365 |
2006 | RMI TITANIUM COMPANY | 4193.00 | 0.00 | 365 |
2007 | RMI TITANIUM COMPANY | 3597.00 | 0.00 | 365 |
2008 | RMI TITANIUM COMPANY | 2622.00 | 0.00 | 365 |
2009 | RMI TITANIUM COMPANY | 2717.00 | 30.00 | 365 |
2010 | RMI TITANIUM COMPANY | 2140.00 | 0.00 | 365 |
2011 | RMI TITANIUM COMPANY | 2874.00 | 0.00 | 0 |
2012 | RMI TITANIUM COMPANY | 2784.00 | 0.00 | 366 |
2013 | RMI TITANIUM COMPANY | 3710.00 | 62.00 | 365 |
2014 | RMI TITANIUM COMPANY | 3530.00 | 0.00 | 365 |
2015 | RMI TITANIUM COMPANY | 3277.00 | 0.00 | 365 |
2016 | RMI TITANIUM COMPANY | 3101.00 | 0.00 | 365 |
2017 | RMI TITANIUM COMPANY | 3598.00 | 0.00 | 365 |
2018 | RMI TITANIUM COMPANY | 3126.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | RMI COMPANY | Brine | 0 | 0 |
2000 | RMI TITANIUM COMPANY | Brine | 0 | 365 |
2001 | RMI TITANIUM COMPANY | Brine | 12 | 365 |
2002 | RMI TITANIUM COMPANY | Brine | 19 | 365 |
2003 | RMI TITANIUM COMPANY | Brine | 0 | 365 |
2004 | RMI TITANIUM COMPANY | Brine | 41 | 365 |
2005 | RMI TITANIUM COMPANY | Brine | 19 | 365 |
2006 | RMI TITANIUM COMPANY | Brine | 24 | 365 |
2007 | RMI TITANIUM COMPANY | Brine | 46 | 365 |
2008 | RMI TITANIUM COMPANY | Brine | 24 | 365 |
2009 | RMI TITANIUM COMPANY | Brine | 11 | 365 |
2010 | RMI TITANIUM COMPANY | Brine | 67 | 365 |
2011 | RMI TITANIUM COMPANY | Brine | 26 | |
2012 | RMI TITANIUM COMPANY | Brine | 18 | 366 |
2013 | RMI TITANIUM COMPANY | Brine | 18 | 365 |
2014 | RMI TITANIUM COMPANY | Brine | 32 | 365 |
2015 | RMI TITANIUM COMPANY | Brine | 42 | 365 |
2016 | RMI TITANIUM COMPANY | Brine | 29 | 365 |
2017 | RMI TITANIUM COMPANY | Brine | 0 | 365 |
2018 | RMI TITANIUM COMPANY | Brine | 29 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1774817887 | 2013-7-25 0:00: | UP | No Violations | 0.50 |
-210484599 | 2013-2-13 0:00: | PW | No Violations | 0.50 |
0210484599 | 2013-02-13 | Production Wells | No Violations | My inspection found the well equipped with a plunger lift unit. The tank battery contained one, 100 barrel production tank. It was surrounded by a weathered dike and not capable of meeting containment requirements. The heat treated separator had the correct spacing and had a 7 day production chart. The lease road was in good condition with a locked gate at the entrance. Its shared with permit number 2-2780. This well was placed into production prior to House Bill 278. The production record were up to date on our database. I called Doug Trevis at 330-544-1165. I instructed him to have a need dike built by 2/22/2013. |
0459197382 | 2016-05-23 | UrbanProduction Wells | No Violations
-17-2016 in the separator. The access road is in good repair with a locked gate at the entrance. RBDMS database shows no statement of annual production filed for 2013 through 2015. I called Doug Travis from RMI Co. and left a message for a return call. The equipment on site consists of: 1 Heat treated mechanical separator 1 Production well | |
1774817887 | 2013-07-25 | UrbanProduction Wells | No Violations | My inspection found a new dike built around the production tank per my request. |
459197382 | 2016-5-23 0:00: | UP | No Violations | 0.70 |
For data sources see[9]