If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-21677 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.25,"lon":-80.54,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Brookfield Township | |
Operator Name: VORTEX ENERGY LLC | |
Well Pad ID: | |
Farm/Lease Name: BROOKFIELD TRI-CO CONS CLUB | |
License Status: Producing | |
License Date: 1980-12-18 | |
Spud Date: 1981-07-10 | |
Spud Drilling Contractor: | |
Final Drill Date: 1981-07-15 | |
Well Total Depth: 4983.00 ft | |
Configuration: Vertical | |
Latitude: 41.250000 | |
Longitude: -80.540000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1980-12-18 | 54 TITAN ENERGY CORP GeoDate 12/18/80 |
Oil and Gas | 1980-12-18 | Issued Date 12/18/80 Expired Date Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000 |
Original Spud | 1981-07-10 | |
Completed | 1981-07-15 | |
Reached Total Depth | 1981-07-15 | |
Completion Report Received | 1982-04-14 | |
Change of Owner | 1998-01-26 | Operator changed from 54, TITAN ENERGY CORP to 1333, BARR ROBT/dba BIG SKY PET |
Change of Owner | 2017-04-13 | Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC |
Record Last Modified | 2017-04-13 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 4854 | 4927 | 21 |
4854 | 4927 | 21 | |
4854 | 4927 | 21 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
N2 | 0 | 200 Mscf | 0 | |||
H2O | 0 | 58000 Gal | 70000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | TITAN ENERGY CORP | 24375.00 | 196.00 | 0 |
1985 | TITAN ENERGY CORP | 18606.00 | 136.00 | 365 |
1986 | TITAN ENERGY CORP | 14750.00 | 71.00 | 365 |
1987 | TITAN ENERGY CORP | 10117.00 | 66.00 | 365 |
1988 | TITAN ENERGY CORP | 9682.00 | 0.00 | 365 |
1989 | B-J OF OHIO INC | 11919.00 | 131.00 | 365 |
1990 | TITAN ENERGY CORP | 7792.00 | 21.00 | 365 |
1991 | TITAN ENERGY CORP | 3224.00 | 0.00 | 365 |
1992 | TITAN ENERGY CORP | 6611.00 | 69.00 | 365 |
1993 | TITAN ENERGY CORP | 4296.00 | 0.00 | 365 |
1994 | TITAN ENERGY CORP | 1357.00 | 85.00 | 365 |
1997 | TITAN ENERGY CORP | 0.00 | 0.00 | 245 |
2000 | BIG SKY ENERGY INC | 17999.00 | 42.00 | 365 |
2001 | BIG SKY ENERGY INC | 13980.00 | 54.00 | 365 |
2002 | BIG SKY ENERGY INC | 6480.00 | 41.00 | 365 |
2003 | BIG SKY ENERGY INC | 5706.00 | 0.00 | 365 |
2004 | BIG SKY ENERGY INC | 6155.00 | 53.00 | 365 |
2005 | BIG SKY ENERGY INC | 5408.00 | 32.00 | 365 |
2006 | BIG SKY ENERGY INC | 3310.00 | 0.00 | 365 |
2007 | BIG SKY ENERGY INC | 3930.00 | 0.00 | 365 |
2008 | BIG SKY ENERGY INC | 4468.00 | 0.00 | 365 |
2009 | BIG SKY ENERGY INC | 2953.00 | 0.00 | 365 |
2010 | BIG SKY ENERGY INC | 2884.00 | 58.00 | 365 |
2011 | BIG SKY ENERGY INC | 2315.00 | 0.00 | 365 |
2012 | BIG SKY ENERGY INC | 3641.00 | 0.00 | 366 |
2013 | BIG SKY ENERGY INC | 2414.00 | 0.00 | 365 |
2014 | BIG SKY ENERGY INC | 2820.00 | 28.00 | 365 |
2016 | BIG SKY ENERGY INC | 31.00 | 0.00 | 98 |
2017 | BIG SKY ENERGY INC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | TITAN ENERGY CORP | Brine | 0 | 0 |
1985 | TITAN ENERGY CORP | Brine | 0 | 365 |
1986 | TITAN ENERGY CORP | Brine | 0 | 365 |
1987 | TITAN ENERGY CORP | Brine | 0 | 365 |
1988 | TITAN ENERGY CORP | Brine | 0 | 365 |
1989 | B-J OF OHIO INC | Brine | 0 | 365 |
1990 | TITAN ENERGY CORP | Brine | 0 | 365 |
1991 | TITAN ENERGY CORP | Brine | 0 | 365 |
1992 | TITAN ENERGY CORP | Brine | 0 | 365 |
1993 | TITAN ENERGY CORP | Brine | 0 | 365 |
1994 | TITAN ENERGY CORP | Brine | 0 | 365 |
1997 | TITAN ENERGY CORP | Brine | 245 | |
2000 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2001 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2002 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2003 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2004 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2005 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2006 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2007 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2008 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2009 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2010 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2011 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2012 | BIG SKY ENERGY INC | Brine | 0 | 366 |
2013 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2014 | BIG SKY ENERGY INC | Brine | 28 | 365 |
2016 | BIG SKY ENERGY INC | Brine | 0 | 98 |
2017 | BIG SKY ENERGY INC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0000PL4087 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
1600787152 | 2020-9-22 0:00: | UP | No Violations | |
1691794055 | 2016-04-28 | Production Wells | Violations Noted | My inspection found the well to be equipped with a plunger lift unit. The valves on the wellhead leading to the flow line are open. The tank battery consists of a 100 BBL production tank and a 50 BBL brine tank. The dike around the tank battery needs to be rebuilt. The heated separator is located outside of the tank battery with the proper spacing. The valves leading from the flow line to the separator and from the separator to the sales line are open. The production chart was last changed on 2/29/16. The well was in the middle of a production cycle during my inspection. The identification sign is not legible and needs replaced. The lease road is in stable condition. |
PL4087 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1691794055 | US-OH-116773 | 2016-06-14 | Failure to legibly identify well |