If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-21755 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.31,"lon":-80.54,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Hartford Township | |
Operator Name: VORTEX ENERGY LLC | |
Well Pad ID: | |
Farm/Lease Name: JONES TERRY | |
License Status: Producing | |
License Date: 1984-11-20 | |
Spud Date: 1984-12-11 | |
Spud Drilling Contractor: ARMSTRONG DRLG | |
Final Drill Date: 1984-12-16 | |
Well Total Depth: 4985.00 ft | |
Configuration: Vertical | |
Latitude: 41.310000 | |
Longitude: -80.540000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1982-02-09 | Issued Date 2/10/82 Expired Date 8/10/82 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000 |
CO | 1984-11-20 | 54 TITAN ENERGY CORP GeoDate 11/20/84 |
Oil and Gas | 1984-11-20 | Issued Date 11/20/84 Expired Date 5/19/85 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 04985 Proposed Drill Depth 04985 |
Original Spud | 1984-12-11 | RI 11-24-84 |
Completed | 1984-12-16 | RI 11-24-84 |
Reached Total Depth | 1984-12-16 | RI 11-24-84 |
CO | 1985-02-02 | 224 ATLAS ENERGY GROUP INC GeoDate 2/9/82 |
Completion Report Received | 1985-02-12 | RI 11-24-84 |
Construction Permit Expires | 1985-05-19 | RI 11-24-84 |
CO | 1995-09-20 | 1639 BASS ENERGY CO INC GeoDate 11/20/84 |
Change of Owner | 2000-10-21 | Operator changed from 1639, BASS ENERGY CO INC to 1333, BARR ROBT/dba BIG SKY PET |
Change of Owner | 2017-04-13 | Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC |
Record Last Modified | 2017-04-13 | RI 11-24-84 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 4776 | 4874 | 0 |
4776 | 4874 | 0 | |
2006-09-11 | 4784 | 4831 | 19 |
4784 | 4831 | 19 | |
4776 | 4874 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 0 | 500 Gal | 0 | FRAC;H2O,SAND,N2 | ||
H2O | 0 | 63420 Gal | 53000 | |||
N2 | 0 | 136200 | 0 | SCF N2 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | TITAN ENERGY CORP | 14540.00 | 44.00 | 321 |
1986 | TITAN ENERGY CORP | 5857.00 | 71.00 | 365 |
1987 | TITAN ENERGY CORP | 2254.00 | 0.00 | 365 |
1988 | TITAN ENERGY CORP | 4979.00 | 0.00 | 365 |
1989 | TITAN ENERGY CORP | 4655.00 | 72.00 | 365 |
1990 | TITAN ENERGY CORP | 4470.00 | 0.00 | 365 |
1991 | TITAN ENERGY CORP | 720.00 | 56.00 | 365 |
1992 | TITAN ENERGY CORP | 2869.00 | 0.00 | 365 |
1993 | TITAN ENERGY CORP | 695.00 | 0.00 | 365 |
1994 | TITAN ENERGY CORP | 177.00 | 0.00 | 365 |
1996 | BASS ENERGY CO INC | 698.00 | 0.00 | 90 |
1997 | BASS ENERGY CO INC | 327.00 | 0.00 | 365 |
1998 | BASS ENERGY CO INC | 0.00 | 0.00 | 365 |
1999 | BASS ENERGY CO INC | 0.00 | 0.00 | 0 |
2000 | BIG SKY ENERGY INC | 2313.00 | 0.00 | 365 |
2001 | BIG SKY ENERGY INC | 2954.00 | 0.00 | 365 |
2002 | BIG SKY ENERGY INC | 172.00 | 0.00 | 365 |
2003 | BIG SKY ENERGY INC | 1402.00 | 0.00 | 365 |
2004 | BIG SKY ENERGY INC | 2842.00 | 0.00 | 365 |
2005 | BIG SKY ENERGY INC | 2892.00 | 29.00 | 365 |
2006 | BIG SKY ENERGY INC | 2580.00 | 40.00 | 365 |
2007 | BIG SKY ENERGY INC | 2020.00 | 55.00 | 365 |
2008 | BIG SKY ENERGY INC | 2316.00 | 36.00 | 365 |
2009 | BIG SKY ENERGY INC | 1527.00 | 0.00 | 365 |
2010 | BIG SKY ENERGY INC | 2466.00 | 76.00 | 365 |
2011 | BIG SKY ENERGY INC | 2383.00 | 0.00 | 365 |
2012 | BIG SKY ENERGY INC | 1686.00 | 0.00 | 366 |
2013 | BIG SKY ENERGY INC | 469.00 | 17.00 | 365 |
2014 | BIG SKY ENERGY INC | 355.00 | 0.00 | 365 |
2016 | BIG SKY ENERGY INC | 378.00 | 0.00 | 98 |
2017 | BIG SKY ENERGY INC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | TITAN ENERGY CORP | Brine | 0 | 321 |
1986 | TITAN ENERGY CORP | Brine | 0 | 365 |
1987 | TITAN ENERGY CORP | Brine | 0 | 365 |
1988 | TITAN ENERGY CORP | Brine | 0 | 365 |
1989 | TITAN ENERGY CORP | Brine | 0 | 365 |
1990 | TITAN ENERGY CORP | Brine | 0 | 365 |
1991 | TITAN ENERGY CORP | Brine | 0 | 365 |
1992 | TITAN ENERGY CORP | Brine | 0 | 365 |
1993 | TITAN ENERGY CORP | Brine | 70 | 365 |
1994 | TITAN ENERGY CORP | Brine | 0 | 365 |
1996 | BASS ENERGY CO INC | Brine | 0 | 90 |
1997 | BASS ENERGY CO INC | Brine | 0 | 365 |
1998 | BASS ENERGY CO INC | Brine | 0 | 365 |
1999 | BASS ENERGY CO INC | Brine | 0 | 0 |
2000 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2001 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2002 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2003 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2004 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2005 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2006 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2007 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2008 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2009 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2010 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2011 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2012 | BIG SKY ENERGY INC | Brine | 0 | 366 |
2013 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2014 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2016 | BIG SKY ENERGY INC | Brine | 0 | 98 |
2017 | BIG SKY ENERGY INC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1040044070 | 2016-6-1 0:00:0 | PW | No Violations | 0.70 |
-1357155752 | 2019-8-1 0:00:0 | PW | No Violations | |
-1746604211 | 2017-1-18 0:00: | PW | No Violations | 0.70 |
-1812256518 | 2020-2-13 0:00: | PW | No Violations | 0.40 |
-1996073828 | 2014-3-5 0:00:0 | PW | No Violations | 1.00 |
-2076677601 | 2019-12-26 0:00 | PW | No Violations | |
-517929107 | 2014-3-5 0:00:0 | PW | No Violations | 1.00 |
-573120193 | 2014-12-4 0:00: | AM | No Violations | 0.20 |
-817074932 | 2019-3-21 0:00: | PW | No Violations | |
-886148146 | 2017-10-17 0:00 | PW | No Violations | 0.50 |
-898627852 | 2019-9-4 0:00:0 | PW | No Violations | |
0000PL4075 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0224062229 | 2012-10-03 | Production Wells | Violations Noted | I found the well equipped with a plunger lift unit. The tank battery contained one, 100 barrel oil storage tank, one, 50 barrel brine storage tank, a separator, and no identification. There is no dike surrounding the tank battery. There is contaminated soil and gravel around both storage tanks. I took photos and emailed the issues to Jamie Campbell the field supervisor for Big Sky. I will conduct follow-up inspection by 11/5/2012. |
0517929107 | 2014-03-05 | Production Wells | No Violations | I was on location to assess compliance notice #224062229. I found a stenciled identification sign with the proper information on the production tank. |
0573120193 | 2014-12-04 | Administrative Inspection | No Violations | I performed an administrative inspection for Compliance Notice #-1996073828, which has been closed at this time. Operator was granted a stay in reference to Chiefs Order 2014-43. |
0817074932 | 2019-03-21 | Production Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice # 1462020385, regarding oil impacted soil at the tank battery location. At the time of my inspection, the oil impacted soil and vegetation between the two production tanks and next to the 50 BBL tank has old staining and not been remediated. A stenciled identification sign was posted on the 100 BBL tank with Vortex Energy, LLC information but needs the well information added.
Vortex still needs to: Scrape up and remove all of the affected material down to good soil or clay. Dispose of the affected material at an approved landfill. Fill in the well information on the identification. |
0886148146 | 2017-10-17 | Production Wells | No Violations
-up inspection will be conducted by 10/27/17. | |
0932502336 | 2014-03-21 | Production Wells | No Violations | I was on location to perform a follow-up inspection to compliance notice #1996073828, which was issued in reference to Chiefs Order 2014-43. My inspection found the well was equipped with a plunger lift unit. The valve leading to the flow line from the well was open. There was a domestic flow line coming off the 4.5 casing. The tank battery consisted of a 100 barrel production tank, a 50 barrel brine tank, and a heat, treated separator. Since the snow has melted, I noticed oil stained soil next the brine tank. The separator had the correct spacing. The identification sign was stenciled to the production tank. Half of the dike was completely weathered not meeting containment requirements. The flow line valves leading to and exiting the separator were open. A new production chart was inside the separator with a date of 3/6. On the chart were double lines representing production. The lease road was in stable condition. Additional photos were taken of all the production equipment. A new dike must be properly built to meet containment requirements. The oil stained soil at the tank battery needs to be removed. The well was in production which was in non-compliance of Chiefs order #2014-43. The well needs to be shut-in immediately. |
1040044070 | 2016-06-01 | Production Wells | No Violations | |
1045408467 | 2019-5-13 0:00: | PW | No Violations | |
1407855052 | 2014-04-28 | Production Wells | No Violations | I was on location to perform a follow-up inspection to compliance notice #1996073828, which was issued in reference to Chiefs Order 2014-43. My inspection found the valve leading to the flow line at the well open. The oil stained soil was still next to the brine tank. Half of the dike was completely weathered not meeting containment requirements. The flow line valves leading to and exiting the separator were open. The production chart inside the separator had a date of 4/23 with no year. The name of the well was on the production chart. Additional photos were taken of all the production equipment. The well was in production which was in non-compliance of Chiefs order #2014-43. The well needs to be shut-in immediately. |
1462020385 | 2016-04-27 | Production Wells | Violations Noted | I was on location in reference to compliance to Chiefs Order 2016-
Big Sky needs to: Remove and properly dispose of all impacted soil and debris affected by the oil release. Remove and properly dispose of the saturated absorbent pads. Repair the surface area affected by the oil release. Remove the black poly pipe. The equipment on the site consists of the following:
|
1746604211 | 2017-01-18 | Production Wells | No Violations
| |
1801784994 | 2020-8-31 0:00: | PW | No Violations | |
1996073828 | 2014-03-05 | Production Wells | Violations Noted | I was on location to check compliance to Chiefs Order 2014-43. My inspection found the well was equipped with a plunger lift unit. The valve leading to the flow line from the well was open. There was a domestic flow line coming off the 4.5 casing. The tank battery consisted of a 100 barrel production tank, a 50 barrel brine tank, and a heat, treated separator. The separator had the correct spacing. The identification sign was stenciled to the production tank. Half of the dike was completely weathered not meeting containment requirements. The flow line valves leading to and exiting the separator were open. There was a production chart inside the separator with no date. The lease road was in stable condition. Photos were taken of all the production equipment. A new dike must be properly built to meet containment requirements. The well was in production which was in non-compliance of Chiefs order #2014-43. The well needs to be shut-in immediately. |
224062229 | 2012-10-3 0:00: | PW | No Violations | 0.50 |
932502336 | 2014-3-21 0:00: | PW | No Violations | 1.00 |
PL4075 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0224062229 | US-OH-122233 | 2012-10-29 | Well operation causing pollution and contamination | |
0224062229 | US-OH-122234 | 2012-10-29 | Failure to legibly identify well | |
0224062229 | US-OH-122235 | 2012-10-29 | No SPCC dike/or failure to keep dike free of water or oil | |
1462020385 | US-OH-113375 | 2016-05-27 | Well operation causing pollution and contamination | |
1996073828 | US-OH-120258 | 2015-02-06 | No SPCC dike/or failure to keep dike free of water or oil | |
1996073828 | US-OH-120259 | 2015-02-06 | Failure to register/obtain or maintain bond/insurance |
For data sources see[9]