X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-21820

Well Details

Well ID: 34-155-21820
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hartford Township
Operator Name: VORTEX ENERGY LLC
Well Pad ID:
Farm/Lease Name: BUCHANAN A
License Status: Producing
License Date: 1981-10-16
Spud Date: 1982-02-09
Spud Drilling Contractor: S W JACK DRLG
Final Drill Date: 1982-02-18
Well Total Depth: 5047.00 ft
Configuration: Vertical
Latitude: 41.300000
Longitude: -80.530000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1981-10-16 182 BELDEN & BLAKE CO GeoDate 10/16/81
Original Spud 1982-02-09
Completed 1982-02-18
Reached Total Depth 1982-02-18
Completion Report Received 1982-03-01
CO 1992-04-03 4265 EMERY DOUGLAS A & MELISSA GeoDate 10/16/81
CO 1992-06-17 54 TITAN ENERGY CORP GeoDate 10/16/81
Change of Owner 2017-06-22 Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC
Record Last Modified 2017-06-22

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4800 4802 2
2001-09-11 4776 4914 17
4776 4914 17
4800 4802 2
4776 4914 17
2006-09-11 4910 4914 3
2006-09-11 4806 4811 4

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1015 Bbl 90000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 POWER GAS MARKETING & TRANS 10643.00 230.00 0
1985 BELDEN & BLAKE CORPORATION 5244.00 195.00 0
1987 BELDEN & BLAKE CORPORATION 2276.00 92.00 365
1988 BELDEN & BLAKE CORPORATION 1622.00 136.00 172
1992 BELDEN & BLAKE CORPORATION 0.00 25.00 366
2000 BIG SKY ENERGY INC 1834.00 173.00 365
2002 BIG SKY ENERGY INC 2690.00 38.00 365
2003 BIG SKY ENERGY INC 1244.00 0.00 365
2004 BIG SKY ENERGY INC 1208.00 31.00 365
2005 BIG SKY ENERGY INC 1603.00 89.00 365
2006 BIG SKY ENERGY INC 1796.00 40.00 365
2013 BIG SKY ENERGY INC 167.00 17.00 250
2014 BIG SKY ENERGY INC 35.00 0.00 365
2016 BIG SKY ENERGY INC 2.00 0.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 POWER GAS MARKETING & TRANS Brine 0 0
1985 BELDEN & BLAKE CORPORATION Brine 61 0
1987 BELDEN & BLAKE CORPORATION Brine 12 365
1988 BELDEN & BLAKE CORPORATION Brine 22 172
1992 BELDEN & BLAKE CORPORATION Brine 7 366
2000 BIG SKY ENERGY INC Brine 0 365
2002 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2013 BIG SKY ENERGY INC Brine 65 250
2014 BIG SKY ENERGY INC Brine 0 365
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1133198952 2016-6-1 0:00:0 PW No Violations 0.50
-366811544 2014-3-5 0:00:0 PW No Violations 1.00
-628617882 2016-4-27 0:00: PW No Violations 0.50
-774484777 2016-5-4 0:00:0 PW No Violations 0.50
0366811544 2014-03-05 Production Wells Violations Noted I was on location to check compliance to Chiefs Order 2014-43. My inspection found the well was equipped with a plunger lift unit. The demco valve and the dump valve to the flow line on the wellhead are open. The tank battery consisted of a 100 barrel production tank, a 50 barrel brine tank, a 30 barrel brine tank, and a separator. There was an identification sign posted on the production tank. The dike meets containment requirements. Two flow line valves exiting the separator were open. There was a production chart inside the separator with no date. According to our database, Big Sky has failed to file annual production records from 2007 to 2012. The lease road was in stable condition with a closed gate. Photos were taken of all the production equipment. The well was in production which was in non-compliance of Chiefs order #2014-43. The well needs to be shut-in immediately.
0628617882 2016-04-27 Production Wells Violations Noted I was on location in reference to compliance to Chiefs Order 2016--29-2016. A compliance notice has been issued for failure to identify. Photos have been taken and available upon request.

Big Sky needs to: Post the proper identification.


The equipment on the site consists of the following:


1 Mechanical separator 1 Production well

0774484777 2016-05-04 Production Wells No Violations I was on location in reference to compliance to Chiefs Order 2016-105. At the time of my inspection, I found no change from my previous inspection on 4-27-
1133198952 2016-06-01 Production Wells No Violations I was on location to assess compliance notice # -628617882. At the time of my inspection, I found the well not in production. An identification sign has been posted on the 100 bbl storage tank. There are no further violations at this time.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0366811544 US-OH-123872 2014-04-04 Failure to register/obtain or maintain bond/insurance
0366811544 US-OH-123873 2014-04-04 Statement of annual production not filed
0628617882 US-OH-127127 2016-06-21 Failure to legibly identify well

For data sources see[9]