If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-22500 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.41,"lon":-80.86,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Bristol Township | |
Operator Name: BIG SKY ENERGY INC | |
Well Pad ID: | |
Farm/Lease Name: BRISTOL SPRINGS COUNTRY CLUB | |
License Status: Producing | |
License Date: 1984-01-18 | |
Spud Date: 1984-02-01 | |
Spud Drilling Contractor: GRISWALD & ASSOC. | |
Final Drill Date: 1984-02-12 | |
Well Total Depth: 4165.00 ft | |
Configuration: Vertical | |
Latitude: 41.410000 | |
Longitude: -80.860000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1984-01-18 | 130 LESLIE OIL & GAS CO INC GeoDate 1/18/84 |
Oil and Gas | 1984-01-18 | Issued Date 12/30/83 Expired Date 6/27/84 Acres 0043324 Tool Type RTF Proposed Formation CLINTON Proposed Depth 04165 Proposed Drill Depth 04165 |
Original Spud | 1984-02-01 | |
Completed | 1984-02-12 | |
Reached Total Depth | 1984-02-12 | |
Completion Report Received | 1984-03-08 | |
Construction Permit Expires | 1984-06-27 | |
CO | 1993-09-27 | 54 TITAN ENERGY CORP GeoDate 1/18/84 |
Change of Owner | 1998-01-26 | Operator changed from 54, TITAN ENERGY CORP to 1333, BARR ROBT/dba BIG SKY PET |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 3900 | 4044 | 0 |
3900 | 4044 | 0 | |
2006-09-11 | 3937 | 4010 | 14 |
3937 | 4010 | 14 | |
3900 | 4044 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 60000 Gal | 45000 | NONE;PRELIMINARY |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | LESLIE OIL & GAS CO INC | 8892.00 | 592.00 | 365 |
1986 | LESLIE OIL & GAS CO INC | 3907.00 | 469.00 | 351 |
1989 | LESLIE OIL & GAS CO INC | 762.00 | 150.00 | 365 |
1990 | LESLIE OIL & GAS CO INC | 1.00 | 169.00 | 365 |
1991 | LESLIE OIL & GAS CO INC | 1096.00 | 142.00 | 365 |
1992 | TITAN ENERGY CORP | 925.00 | 124.00 | 365 |
1994 | TITAN ENERGY CORP | 352.00 | 75.00 | 365 |
1997 | TITAN ENERGY CORP | 0.00 | 40.00 | 245 |
2000 | BIG SKY ENERGY INC | 0.00 | 0.00 | 365 |
2001 | BIG SKY ENERGY INC | 75.00 | 0.00 | 365 |
2002 | BIG SKY ENERGY INC | 162.00 | 0.00 | 365 |
2003 | BIG SKY ENERGY INC | 0.00 | 66.00 | 365 |
2004 | BIG SKY ENERGY INC | 457.00 | 25.00 | 365 |
2005 | BIG SKY ENERGY INC | 344.00 | 0.00 | 365 |
2006 | BIG SKY ENERGY INC | 235.00 | 287.00 | 365 |
2007 | BIG SKY ENERGY INC | 75.00 | 107.00 | 365 |
2008 | BIG SKY ENERGY INC | 0.00 | 0.00 | 365 |
2009 | BIG SKY ENERGY INC | 939.00 | 0.00 | 365 |
2010 | BIG SKY ENERGY INC | 395.00 | 92.00 | 365 |
2011 | BIG SKY ENERGY INC | 25.00 | 0.00 | 365 |
2012 | BIG SKY ENERGY INC | 193.00 | 0.00 | 366 |
2013 | BIG SKY ENERGY INC | 356.00 | 0.00 | 300 |
2014 | BIG SKY ENERGY INC | 805.00 | 106.00 | 365 |
2016 | BIG SKY ENERGY INC | 47.00 | 0.00 | 98 |
2017 | BIG SKY ENERGY INC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | LESLIE OIL & GAS CO INC | Brine | 630 | 365 |
1986 | LESLIE OIL & GAS CO INC | Brine | 545 | 351 |
1989 | LESLIE OIL & GAS CO INC | Brine | 0 | 365 |
1990 | LESLIE OIL & GAS CO INC | Brine | 489 | 365 |
1991 | LESLIE OIL & GAS CO INC | Brine | 0 | 365 |
1992 | TITAN ENERGY CORP | Brine | 0 | 365 |
1994 | TITAN ENERGY CORP | Brine | 70 | 365 |
1997 | TITAN ENERGY CORP | Brine | 245 | |
2000 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2001 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2002 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2003 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2004 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2005 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2006 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2007 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2008 | BIG SKY ENERGY INC | Brine | 6 | 365 |
2009 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2010 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2011 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2012 | BIG SKY ENERGY INC | Brine | 0 | 366 |
2013 | BIG SKY ENERGY INC | Brine | 116 | 300 |
2014 | BIG SKY ENERGY INC | Brine | 589 | 365 |
2016 | BIG SKY ENERGY INC | Brine | 0 | 98 |
2017 | BIG SKY ENERGY INC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1286411547 | 2014-4-10 0:00: | PW | No Violations | 1.00 |
-1660003801 | 2013-9-24 0:00: | PW | No Violations | |
-1692148571 | 2013-11-6 0:00: | PW | No Violations | 0.50 |
-1694037204 | 2016-4-29 0:00: | PW | No Violations | 0.70 |
-2007848716 | 2014-4-14 0:00: | PW | No Violations | 2.50 |
-2008131406 | 2016-6-27 0:00: | PW | No Violations | 0.70 |
-2040744135 | 2013-9-10 0:00: | PW | No Violations | 1.00 |
-2111719213 | 2017-12-7 0:00: | PW | No Violations | 0.70 |
-233315096 | 2014-4-24 0:00: | AM | No Violations | 0.20 |
-572123044 | 2014-6-4 0:00:0 | PW | No Violations | 0.50 |
0000PL3783 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0097690663 | 2019-03-13 | Production Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 1694037204, regarding cleanup of oil impacted soil at the well and tank battery locations, identification needing installed and repair of the fencing around the well. At the time of this inspection, the oil impacted soil at the separator and base of the 210 BBL storage tank had not been cleaned up. The identification sign posted is blank. The oil impacted soil and vegetation at the wellhead has not been removed. The wooden panels on the fence surrounding the pumping unit have fallen over onto the ground and need reinstalled. |
0233315096 | 2014-04-24 | Administrative Inspection | No Violations | I performed an administrative inspection in reference to Chiefs Order 2014-43. I received a call and spoke to the golf course owners lawyer. He stated Bob Barr Jr. was on location putting the pumping unit into production. He stated the golf course maintenance crew was video taping Bob performing the act. |
0572123044 | 2014-06-04 | Production Wells | No Violations | I received a call at 1:56pm from the Bristolwood Golf Course owner stating that Bob Barr Jr. was on location with three employees, a tanker truck and a pick-up truck operating the well. When I arrived at the golf course; Big Sky was not on location. I spoke to the owner; who showed me photos of Big Sky working at the well and tank battery. Big Skys operation of the well was in non-compliance with Chiefs Order 2014-43. |
0763693824 | 2016-07-07 | Production Wells | No Violations | I was on location to assess compliance notice # -1694037204. At the time of my inspection, I found the well not in production. Peat sorb is still spread over the oil impacted areas inside and outside the fence surrounding the well. The operator has not removed the impacted soil and vegetation from inside and outside of the fence surrounding the well. Another panel section of the fence surrounding the well has fallen. Photos have been taken and are available upon request.
The operator still needs to: Repair the wellhead to prevent further oil leaks. Remove and dispose of all oil impacted soil and vegetation at the well, separator, and 210 bbl tank. Repair all surface areas affected by the oil releases. Repair the fence around the pumping unit. |
0824005944 | 2016-06-14 | Production Wells | No Violations | I was on location to assess compliance notice # -1694037204. At the time of my inspection, I found the well not in production. Peat sorb is still spread over the oil impacted areas inside and outside the fence surrounding the well. The operator has not removed the impacted soil and vegetation from inside and outside of the fence surrounding the well. Photos have been taken and are available upon request.
The operator still needs to: Repair the wellhead to prevent further oil leaks. Remove and dispose of all oil impacted soil and vegetation at the well, separator, and 210 bbl tank. Repair all surface areas affected by the oil releases. |
1286411547 | 2014-04-10 | Production Wells | No Violations | I performed a follow-up inspection concerning the clean-up operations for the oil spill. My inspection found all of the impacted grass and soil removed. The 210 barrel production tank was cleaned of all oil. Peat moss was spread over the entire impacted area. The well tender was on location and stated a new identification sign had been ordered. I will follow-up on the identification sign. Photos were taken. |
1336614562 | 2014-02-28 | Production Wells | Violations Noted | I checked this well to determine if the company is in compliance with chiefs order # 2014-43 . I found the tank battery is equipped with 1 100 bbl , 1 210 bbl steel tanks and 1 separator . The 100 bbl tank was empty and the 210 bbl tank was 1/3 full of fluid . The date marked on chart on gas meter was 2-26 , the year was not indicated . The identification sign posted on the 210 bbl tank was mostly ripped off and was not legible which is in violation of 1501: 9-9-05 , A-10 of the Ohio Administrative Rule . The valve from the flow line to the separator was closed . The earthen dike protecting the tank battery is not of sufficient size to contain the amount of fluid which could be stored in the production tanks , which is in violation of 1501:9-9-05 , A-9 of the Ohio Administrative Rule . At the well location I found the well is equipped with a pumping unit , the pumping unit was not in operation at the time of my inspection . There is a domestic hook-up from the production casing with the valve closed . There is a 6 wood fence surrounding the pumping unit . NOTE : This well is located on the Bristolwood Golf Course . This well was not in production at the time of my inspection . |
1378992713 | 2013-09-06 | Production Wells | No Violations | I received a inspection request from the Bristolwood Golf Course. My inspection found the well not in production. The well was equipped with a pumping unit with all the valves to the flow line closed. The well was surrounded by a wooden fence with half of the panels either missing or lying on the ground. I noticed a 4 diameter greasy black stain and an 18 diameter muddy area on the grass located approximately 6 southeast from the pump unit. The head maintenance employee, Leroy, claimed a Big Sky crew had been on location working on the well the entire week (9/3/13 to 9/5/13). The tank battery contained a 100 barrel production tank, a 50 barrel brine tank, and a separator. The dike was slightly weathered; however, it meets containment requirements. There was no identification sign posted. I called Valerie Dunne of Well Completion Services at 440-858-2343. Valerie stated she would dispatch Ryan, their well tender, to meet me on location. Once Ryan arrived at the golf course, he claimed the well was shut-in to replace the rods, which caused the greasy black stain on the grass. Also, he said the muddy area was a flow line leak. Big Sky pumped fresh water from the tank battery through the flow line to locate the leak. I instructed Ryan to begin repairs on the flow line immediately, post the proper identification sign, and replace the wood fence panels. At 11:20am, I received a call from Bob Barr, Jr. He stated Big Sky would start repairs on the flow line by 9/10/13. I took photos of the well location. |
1462365166 | 2016-05-04 | Production Wells | No Violations | I was on location in reference to compliance to Chiefs Order 2016-105. At the time of my inspection, I found no change from my previous inspection on 4-29- |
1464278238 | 2016-05-20 | Production Wells | No Violations | I was on location to assess compliance to Chiefs Order 2016- |
1464369127 | 2016-05-27 | Production Wells | No Violations | I was on location to assess compliance to Chiefs Order 2016- |
1512583642 | 2016-05-26 | Production Wells | No Violations | I was on location with ODNR Operations and Response Manager Terry Whitehair and ODNR Operations Coordinator Fred Romeo. I found a pool of oil outside of the fenced pumping unit on the south side. The area of impact is approximately 6 in diameter. The wellhead is coated with oil and paraffin. The vegetation in an area approximately 6 x 3 in front of the wellhead is impacted by oil. The well is shut-in with closed 2 flow line ball valves coming off of the wellhead. I contacted Big Sky Energy to respond immediately to the oil spill. Photos were taken and are available upon request. |
1522326807 | 2018-03-12 | Production Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 1694037204. The oil impacted soil at the separator and base of the 210 BBL storage tank had not been cleaned up. The identification sign posted is blank. The oil impacted soil and vegetation at the wellhead has not been removed. The wooden panels on the fence surrounding the pumping unit have fallen over onto the ground and need reinstalled. |
1546218246 | 2013-09-11 | Production Wells | No Violations | My inspection found the flow line repaired, soil compacted, seeded, and straw spread. I took photos of the repair. |
1561790158 | 2013-10-01 | Production Wells | No Violations | I performed a follow up inspection of the brine spill from the tank battery. My inspection found lime spread throughout the tank battery and lease road. I noticed a section of grass next to the lease road southwest of the tank battery that was brine scolded. The approximate area was 2 wide by 15 long. According to ODNR Inspector Kevin Perry, Bob Barr, Jr. told Kevin that Big Sky would till up the brine scolded area next to the lease road and re-seed. I called Bob Barr, Jr. at 740-624-0434 and left a message to finish tilling the affected grass area, then seed. |
1660003801 | 2013-09-24 | Production Wells | No Violations | I was on location today in reference to complaint #4467. Bob Barr Jr. was on location with K.D.A. vac truck. The 100 BBL brine tank had rusted through on the bottom of the tank. The brine brine that escaped through the dike had pooled up in the lease road and some made it into the grass. Bob said that he has a crew on the way over to the location. The are going to till up the affected area, mix in soil and lime, and then seed and straw the area. The 100 BBL tank is going to be removed from the location. I informed him that he needs identification on the location. The fence around the pump jack needs repaired. The stuffing box seals need to be repaired and the area around the wellhead needs cleaned up. |
1692148571 | 2013-11-06 | Production Wells | No Violations | My inspection found the wooden fence surrounding the pumping unit repaired and newly painted. The brine scald near the tank battery was removed and the soil tilled; new grass seed was spread. |
1694037204 | 2016-04-29 | Production Wells | Violations Noted | I was on location in reference to compliance to Chiefs Order 2016--2-
Big Sky needs to: Shut in the well immediately per the temporary restraining order issued by the Trumbull County Court of Common Pleas dated 4-11-2016 Repair the oil leak at the well. Remove and dispose of all oil impacted soil and vegetation at the well, separator, and 210 bbl tank. Repair all surface areas affected by the oil releases. The equipment on the site consists of the following:
|
2007848716 | 2014-04-14 | Production Wells | No Violations | I responded to a call about an oil spill at the tank battery. My inspection found the 210 barrel production tank covered with oil. There was an approximately 20 gallons of oil lying around the 210 barrel production tank and between the production tank and 100 barrel brine tank. All of the oil was contained inside the dike. I noticed the identification was ripped in half. Bobby Barr of Big Sky was on location. I instructed Bobby to suck up all of the oil, remove all of the impacted grass and soil, clean all of the oil off the production tank, and replace the identification sign. I questioned Bobby as to why the tank overflowed when the well was supposed to be shut-in per Chiefs Order 2014-43. Bobby claimed the well was shut-in. Photos were taken. |
2008131406 | 2016-06-27 | Production Wells | No Violations | I was on location to assess compliance notice # -1694037204. At the time of my inspection, I found the well not in production. Peat sorb is still spread over the oil impacted areas inside and outside the fence surrounding the well. The operator has not removed the impacted soil and vegetation from inside and outside of the fence surrounding the well. A panel section of the fence surrounding the well is still lying on the ground. Photos have been taken and are available upon request.
The operator still needs to: Repair the wellhead to prevent further oil leaks. Remove and dispose of all oil impacted soil and vegetation at the well, separator, and 210 bbl tank. Repair all surface areas affected by the oil releases. |
2040744135 | 2013-09-10 | Production Wells | No Violations | My inspection found Bob Barr, Jr. and crew making repairs to the flow line next to the well. I noticed a 2 black poly flow line was exposed. The line was approximately 12 deep. Bob stated once the flow line was repaired; the soil would be compacted into place and seeded. I noticed no evidence of any impacted soil from the flow line leak. To prevent a safety hazard to the golfers, I told Bob further inspections of the well would continue until the fallen and missing wooden panels surrounding the pumping unit where repaired. |
2111719213 | 2017-12-07 | Production Wells | No Violations | I was on location to assess compliance notice # -1694037204. I found the oil impacted soil at the separator and base of the 210 bbl. storage tank has not been cleaned up. The identification sign posted is blank. The bottom of the separator has holes from corrosion. The oil impacted soil and vegetation at the wellhead has not been removed. The wooden panels on the fence surrounding the pumping unit have fallen over onto the ground. Photos have been taken and are available upon request.
The operator still needs to: Repair the wellhead to prevent further oil leaks. Remove and dispose of all oil impacted soil and vegetation at the well, separator, and 210 bbl. tank. Repair all surface areas affected by the oil releases. Repair the fence around the pumping unit. |
763693824 | 2016-7-7 0:00:0 | PW | No Violations | 0.70 |
824005944 | 2016-6-14 0:00: | PW | No Violations | 1.00 |
97690663 | 2019-3-13 0:00: | PW | No Violations | |
PL3783 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1336614562 | US-OH-109687 | 2014-03-21 | Failure to legibly identify well | |
1336614562 | US-OH-109688 | 2014-03-21 | No SPCC dike/or failure to keep dike free of water or oil | |
1694037204 | US-OH-116792 | 2016-05-27 | Well operation causing pollution and contamination |
For data sources see[9]