Well Details

Well ID: 34-155-22657
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hartford Township
Operator Name: VORTEX ENERGY LLC
Well Pad ID:
Farm/Lease Name: BLANEY
License Status: Producing
License Date: 1984-10-09
Spud Date: 1985-01-18
Spud Drilling Contractor: ARMSTRONG DRLG
Final Drill Date: 1985-01-22
Well Total Depth: 5071.00 ft
Configuration: Vertical
Latitude: 41.290000
Longitude: -80.570000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1984-10-09 Issued Date 10/9/84 Expired Date 4/7/85 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05071 Proposed Drill Depth 05071
Original Spud 1985-01-18
Completed 1985-01-22
Reached Total Depth 1985-01-22
CO 1985-02-22 54 TITAN ENERGY CORP GeoDate 10/9/84
Completion Report Received 1985-02-27
Construction Permit Expires 1985-04-07
Change of Owner 1998-01-26 Operator changed from 54, TITAN ENERGY CORP to 1333, BARR ROBT/dba BIG SKY PET
Change of Owner 2017-06-22 Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC
Record Last Modified 2017-06-22

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4867 4939 0
4867 4939 0
2006-09-11 4872 4933 19
4872 4933 19
4867 4939 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 180 Mscf 0
H2O 0 79968 Gal 70000
ACID 0 500 Gal 0 FRAC;H2O,SAND,N2

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 TITAN ENERGY CORP 15368.00 113.00 290
1986 TITAN ENERGY CORP 14566.00 0.00 365
1987 TITAN ENERGY CORP 783.00 0.00 365
1988 TITAN ENERGY CORP 3588.00 74.00 365
1989 TITAN ENERGY CORP 1808.00 40.00 365
1990 TITAN ENERGY CORP 1862.00 48.00 365
1992 TITAN ENERGY CORP 23.00 0.00 365
1993 TITAN ENERGY CORP 0.00 0.00 365
1994 TITAN ENERGY CORP 0.00 0.00 365
1997 TITAN ENERGY CORP 0.00 0.00 245
2000 BIG SKY ENERGY INC 2591.00 0.00 365
2001 BIG SKY ENERGY INC 819.00 0.00 365
2002 BIG SKY ENERGY INC 1522.00 34.00 365
2003 BIG SKY ENERGY INC 1558.00 0.00 365
2004 BIG SKY ENERGY INC 1231.00 0.00 365
2005 BIG SKY ENERGY INC 1948.00 63.00 365
2006 BIG SKY ENERGY INC 1777.00 59.00 365
2007 BIG SKY ENERGY INC 1294.00 0.00 365
2008 BIG SKY ENERGY INC 1385.00 0.00 365
2009 BIG SKY ENERGY INC 2110.00 0.00 365
2010 BIG SKY ENERGY INC 2679.00 42.00 365
2011 BIG SKY ENERGY INC 1903.00 27.00 365
2012 BIG SKY ENERGY INC 753.00 0.00 366
2013 BIG SKY ENERGY INC 634.00 0.00 365
2014 BIG SKY ENERGY INC 807.00 0.00 365
2016 BIG SKY ENERGY INC 101.00 0.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 TITAN ENERGY CORP Brine 0 290
1986 TITAN ENERGY CORP Brine 0 365
1987 TITAN ENERGY CORP Brine 0 365
1988 TITAN ENERGY CORP Brine 0 365
1989 TITAN ENERGY CORP Brine 0 365
1990 TITAN ENERGY CORP Brine 0 365
1992 TITAN ENERGY CORP Brine 0 365
1993 TITAN ENERGY CORP Brine 0 365
1994 TITAN ENERGY CORP Brine 0 365
1997 TITAN ENERGY CORP Brine 245
2000 BIG SKY ENERGY INC Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2002 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2007 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2010 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 365
2014 BIG SKY ENERGY INC Brine 70 365
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-430835103 2016-9-7 0:00:0 PW No Violations 0.50
-85421508 2012-6-14 0:00: PW No Violations 0.50
-903996084 2008-8-21 0:00: PW No Violations
0000PL3664 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0085421508 2012-06-14 Production Wells Violations Noted On 6/14/2012, I completed a production well inspection status check. My inspection found the well was a plunger lift unit (rabbit) that was in good condition. The tank battery contained one 100 barrel oil storage tank, one 50 barrel brine storage tank, a separator, and an identification sign with no information. I noticed evidence of a spill from an overflow from the 100 barrel oil storage tank and the weeds/grass were overgrown around the separator and tank battery making the inspection difficult. I called Bob Barr and left a message to place the correct information on the identification sign. I reviewed the production records in our database and found there was no production submitted for 2011. Inspection not passed.
0430835103 2016-09-07 Production Wells No Violations
0588774351 2018-03-14 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1461840669. At the time of my inspection, the well was equipped with a plunger lift assembly and the annulus and flow line valves were open. The valve on the 2 inch domestic line off of the 4.5 inch casing was also open. The tank battery consisted of one 100 BBL production tank, one 50 BBL steel brine tank and a mechanical separator. Valves on the separator were open and the chart showed production. The dike around the tank battery still needs to be rebuilt and signage needs to be installed with new information. The lease access was stable. I contacted Vortex Energy, LLC and left a message regarding the rebuilding of the tank battery dike and installing updated signage.
0903996084 2008-08-21 Production Wells No Violations no violations .
1354283210 2012-11-30 Production Wells No Violations My inspection found the proper identification sign posted on the 100 barrel oil storage tank.
1461840669 2016-04-27 Production Wells Violations Noted I was on location in reference to compliance to Chiefs Order 2016-

Big Sky needs to: Remove and properly dispose of the oil. Remove and properly dispose of all impacted soil and debris. Remove and properly dispose of the saturated absorbent pad. Repair the surface area affected by the oil release. Post a proper identification sign. Build a dike around the storage tanks.

The equipment on the site consists of the following:


1 Mechanical separator

1718801110 2014-03-05 Production Wells No Violations I was on location to check compliance to Chiefs Order 2014-43. My inspection found the well was equipped with a plunger lift unit. The valve leading to the flow line from the well was open. There was a domestic flow line coming off the 4.5 casing. The tank battery consisted of a 100 barrel production tank, a 50 barrel brine tank, and a heat, treated separator. The separator had the correct spacing. There was a stenciled identification sign posted on the production tank. The tank battery is within 10 of agricultural fields. The dike was completely weathered and not in compliance with OAC 1501:9-9-05 (9). The flow line valves leading to and exiting the separator were open. There was a production chart inside the separator with no date. The lease road was in stable condition. Photos were taken of all the production equipment. The well was in production which was in non-compliance of Chiefs order #2014-43. The well needs to be shut-in immediately.
1895102638 2007-07-17 Production Wells No Violations no violations .
2076051169 2019-5-20 0:00: PW No Violations
588774351 2018-3-14 0:00: PW No Violations
PL3664 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0085421508 US-OH-129734 2013-08-19 Failure to legibly identify well
1461840669 US-OH-113366 2016-05-25 Well operation causing pollution and contamination
1461840669 US-OH-113367 2016-05-25 Failure to legibly identify well
1461840669 US-OH-113368 2016-05-25 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[9]

References