Well ID: 34-155-23128 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.18,"lon":-80.55,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Hubbard Township | |
Operator Name: PAC DRILLING LLC | |
Well Pad ID: | |
Farm/Lease Name: EVANS | |
License Status: Producing | |
License Date: 2011-12-29 | |
Spud Date: 2012-02-11 | |
Spud Drilling Contractor: G & H DRLG | |
Final Drill Date: 2012-02-16 | |
Well Total Depth: 5515.00 ft | |
Configuration: Vertical | |
Latitude: 41.180000 | |
Longitude: -80.550000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1987-11-10 | 1388 NORTH COAST ENERGY INC GeoDate 11/10/87 |
Oil and Gas | 1987-11-10 | Issued Date 11/10/87 Expired Date 11/9/88 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000 |
CO | 1988-12-23 | 1388 NORTH COAST ENERGY INC GeoDate 12/23/88 |
Oil and Gas | 1988-12-23 | Issued Date 12/23/88 Expired Date 12/23/89 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000 |
APP | 2011-12-29 | Proposed Formations:CLINTON & MEDINA, Issued Date:12/29/2011, Expired Date:12/28/2013 12:00:00 PM, Drilling unit acres:46, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2012-02-16 | RI 12-24-88 PERMIT EXPIRED. |
Completion Report Received | 2012-06-21 | RI 12-24-88 PERMIT EXPIRED. |
Construction Permit Expires | 2012-12-28 | RI 12-24-88 PERMIT EXPIRED. |
Record Last Modified | 2017-10-24 | RI 12-24-88 PERMIT EXPIRED. |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2012-07-19 | 5266 | 5270 | 5 |
2012-07-19 | 5244 | 5258 | 15 |
5218 | 5232 | 15 | |
5244 | 5258 | 15 | |
5266 | 5270 | 5 | |
5274 | 5277 | 5 | |
5291 | 5294 | 5 | |
5358 | 5370 | 20 | |
5218 | 5232 | 15 | |
2012-07-19 | 5218 | 5232 | 15 |
2012-07-19 | 5358 | 5370 | 20 |
2012-07-19 | 5291 | 5294 | 5 |
2012-07-19 | 5274 | 5277 | 5 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2012-02-22 | H2O | 20 | 136929 Gal | 50000 | Universal Well Services Inc. | CLINTON/MEDINA PROD |
2012-02-22 | H2O | 20 | 136929 Gal | 0 | Universal Well Services Inc. | 500 sacks of sand
No problems were encountered. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | PAC DRILLING LLC | 10923.00 | 960.00 | 208 |
2013 | PAC DRILLING LLC | 14288.00 | 638.00 | 365 |
2014 | PAC DRILLING LLC | 12441.00 | 264.00 | 360 |
2015 | PAC DRILLING LLC | 10534.00 | 267.00 | 360 |
2016 | PAC DRILLING LLC | 7788.00 | 339.00 | 359 |
2017 | PAC DRILLING LLC | 6481.00 | 172.00 | 359 |
2018 | PAC DRILLING LLC | 6267.00 | 345.00 | 359 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | PAC DRILLING LLC | Brine | 328 | 208 |
2013 | PAC DRILLING LLC | Brine | 57 | 365 |
2014 | PAC DRILLING LLC | Brine | 24 | 360 |
2015 | PAC DRILLING LLC | Brine | 58 | 360 |
2016 | PAC DRILLING LLC | Brine | 0 | 359 |
2017 | PAC DRILLING LLC | Brine | 0 | 359 |
2018 | PAC DRILLING LLC | Brine | 0 | 359 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1004044866 | 2018-5-21 0:00: | UP | No Violations | |
-134891047 | 2012-2-16 0:00: | UD | No Violations | |
-1970302404 | 2019-3-8 0:00:0 | UP | No Violations | |
-238492367 | 2020-3-27 0:00: | UP | No Violations | |
-911122073 | 2012-2-12 0:00: | UD | No Violations | |
0134891047 | 2012-02-16 | Urban Drill / Deepen / Reopen | No Violations | The rig was drilling on air at 4957. There was a show of gas encountered at 4878. All preparations have been made to convert to fluid, if needed. There were no violations. |
0218627333 | 2017-03-29 | UrbanProduction Wells | No Violations
-up lines have plugs and the ball valve handles have been removed. The 210 bbl. storage tank has the required urban safety equipment. A deduct meter and 31 day chart is installed at the separator. An identification sign is posted at the tank battery. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a--site inspection. The equipment on the pad consists of the following:
| |
0911122073 | 2012-02-12 | Urban Drill / Deepen / Reopen | No Violations | The surface casing installation and cementing was witnessed. The 8.675 casing was set at 723 and cemented with 260 sacks of cement. The cement operation and site conditions were acceptable. |
0957577052 | 2013-05-29 | UrbanPreliminary Restoration | No Violations | My inspection found the well in production. The well was equipped with a plunger lift unit. The tank battery contained one, 210 barrel production tank, one, 50 barrel brine tank, and a separator. It was surrounded by a locked chain link fence and the proper dike capable of meeting containment requirements. There was a plug on the load line. The proper safety equipment was installed on the production tank. An identification sign was properly posted at the wellhead and tank battery. There was a 7 day production chart at the separator. The site was graded and vegetated. All drainage and erosion controls were in place and working properly. The lease road was in good condition. |
1004044866 | 2018-05-21 | UrbanProduction Wells | Violations Noted | At the time of this inspection, the well was equipped with a plunger lift assembly. The annulus and flow line valves were open. An identification sign was posted at the well. The fencing around the well had been partially installed and needed completed. The well was located in a clearing surrounded by woodlands with all private residents approximately over 600 feet away. The diked tank battery has two storage tanks and a separator. The pick-up lines have plugs and the valve handles have been removed. The 210 BBL storage tank has the required urban safety equipment. An identification sign was posted at the tank battery. The identification sign was missing the required information per 1501:9-9-05(E)(1)(a-e). There was a danger, keep out and no smoking sign(s) posted. There was a locked chain link fence surrounding the tank battery. The 3 strand barb wire needed added to the top of the fence. The production tank is over 3 foot above the top of the fence and needs to meet requirements per 1501:9-9--site inspection. |
1330438200 | 2012-02-17 | Urban Drill / Deepen / Reopen | No Violations | The 4.5 production casing was successfully cemented. All conditions were satisfactory. |
1333742789 | 2012-03-08 | Drill / Deepen / Reopen | No Violations | My inspection of this well site found that the pits were solidified using two loads of dust. There were no violations noted. |
1416250308 | 2012-02-27 | Urban Drill / Deepen / Reopen | No Violations | The pits were in good condition. No problems were found. |
1885617342 | 2012-02-13 | Urban Drill / Deepen / Reopen | No Violations | The blowout preventer (BOP) was tested with 330 PSI for 20 minutes. During this test, a 10 PSI decline was observed. The drilling contractor was given instructions to repair leak and ensure the BOP would perform properly. |
1970302404 | 2019-03-08 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 1004044866, regarding multiple compliance issues related to urban rule requirements. At the time of this inspection, the fencing around the well had been partially installed and needed completed. The identification posted at the tank battery has been amended with the required information per 1501:9-9-05(E)(1)(a-e). The 3 strand barb wire needed added to the top of the fence. The production tank is over 3 foot above the top of the fence and needs to meet requirements per 1501:9-9-05E(4)(f). The access gate at the entrance has not been installed. The access road gate was not waived during the pre-site inspection and needs installed with a lock and identification.
PAC needs to: 1) Raise the fencing around the tank battery or use low profile tanks as required by 1501:9-9-05E(4)(f). 2) Install the required gate with a lock at the access road entrance per 1501:9-9-05(E)(2)(c). 3) Post the proper identification sign on the access road gate per 1501:9-9-05E(1)(f). 4) Complete the installation of the fencing around the well. |
218627333 | 2017-3-29 0:00: | UP | No Violations | 0.70 |
957577052 | 2013-5-29 0:00: | UL | No Violations | 0.50 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1004044866 | US-OH-100485 | 2018-05-25 | 9-05E1 | ID (a-i) |
1004044866 | US-OH-100486 | 2018-05-25 | 9-05E2 | FENCING (a-d) |
1004044866 | US-OH-100487 | 2018-05-25 | 9-05E4 | TANKS (a-i) |
1004044866 | US-OH-100488 | 2018-05-25 | 9-9-02 | General Safety |