If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-23223 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.26,"lon":-80.89,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Warren Township | |
Operator Name: PAC DEVELOPMENT LLC | |
Well Pad ID: | |
Farm/Lease Name: NATALE (SWIW #29) | |
License Status: Active Injection | |
License Date: 2013-02-01 | |
Spud Date: 1989-01-31 | |
Spud Drilling Contractor: SHERMAN DRLG | |
Final Drill Date: 1989-02-05 | |
Well Total Depth: 4521.00 ft | |
Configuration: Vertical | |
Latitude: 41.260000 | |
Longitude: -80.890000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1988-09-13 | 2655 KLEESE DEVELOPMENT ASSOCS GeoDate 9/13/88 |
Oil and Gas | 1988-09-13 | Issued Date 9/13/88 Expired Date 9/13/89 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04521 Proposed Drill Depth 04521 |
Original Spud | 1989-01-31 | PLUGGED BACK AND CONVERTED TO SALTWATER INJECTION INTO THE NEWBURG - 8/6/2013 - TET - SPECIFC GRAVITY ADJUSTMENT - <1.10 INCREASE IN INJECTION PSI TO 1070 PSI |
Completed | 1989-02-05 | PLUGGED BACK AND CONVERTED TO SALTWATER INJECTION INTO THE NEWBURG - 8/6/2013 - TET - SPECIFC GRAVITY ADJUSTMENT - <1.10 INCREASE IN INJECTION PSI TO 1070 PSI |
Reached Total Depth | 1989-02-05 | PLUGGED BACK AND CONVERTED TO SALTWATER INJECTION INTO THE NEWBURG - 8/6/2013 - TET - SPECIFC GRAVITY ADJUSTMENT - <1.10 INCREASE IN INJECTION PSI TO 1070 PSI |
Completion Report Received | 1990-03-14 | PLUGGED BACK AND CONVERTED TO SALTWATER INJECTION INTO THE NEWBURG - 8/6/2013 - TET - SPECIFC GRAVITY ADJUSTMENT - <1.10 INCREASE IN INJECTION PSI TO 1070 PSI |
APP | 2013-02-01 | Proposed Formations:NEWBURG, Issued Date:2/1/2013, Expired Date:2/1/2015 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:SWD, Proposed Well Class:SWIW |
Annulus Pressure Monitoring Approved | 2013-04-30 | PLUGGED BACK AND CONVERTED TO SALTWATER INJECTION INTO THE NEWBURG - 8/6/2013 - TET - SPECIFC GRAVITY ADJUSTMENT - <1.10 INCREASE IN INJECTION PSI TO 1070 PSI |
Plugged Back | 2013-04-30 | PLUGGED BACK AND CONVERTED TO SALTWATER INJECTION INTO THE NEWBURG - 8/6/2013 - TET - SPECIFC GRAVITY ADJUSTMENT - <1.10 INCREASE IN INJECTION PSI TO 1070 PSI |
Last Compliance Report | 2013-09-12 | PLUGGED BACK AND CONVERTED TO SALTWATER INJECTION INTO THE NEWBURG - 8/6/2013 - TET - SPECIFC GRAVITY ADJUSTMENT - <1.10 INCREASE IN INJECTION PSI TO 1070 PSI |
Construction Permit Expires | 2015-02-01 | PLUGGED BACK AND CONVERTED TO SALTWATER INJECTION INTO THE NEWBURG - 8/6/2013 - TET - SPECIFC GRAVITY ADJUSTMENT - <1.10 INCREASE IN INJECTION PSI TO 1070 PSI |
Change of Owner | 2016-05-19 | Operator changed from 2655, KLEESE DEVELOPMENT ASSOCS to 9678, PAC DEVELOPMENT LLC |
Record Last Modified | 2017-02-15 | PLUGGED BACK AND CONVERTED TO SALTWATER INJECTION INTO THE NEWBURG - 8/6/2013 - TET - SPECIFC GRAVITY ADJUSTMENT - <1.10 INCREASE IN INJECTION PSI TO 1070 PSI |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2013-08-06 | 3912 | 4036 | 304 |
4226 | 4331 | 0 | |
1997-06-29 | 4226 | 4331 | 0 |
4241 | 4263 | 11 | |
3912 | 4036 | 304 | |
3912 | 4036 | 304 | |
2006-09-11 | 4241 | 4263 | 11 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 104850 Gal | 0 | SLICKWATER FRAC |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1027744807 | 2013-7-15 0:00: | SW | No Violations | |
-1040400902 | 2018-7-23 0:00: | SW | No Violations | 0.80 |
-1047860150 | 2015-12-3 0:00: | SW | No Violations | 0.50 |
-1062241582 | 2020-4-30 0:00: | SW | No Violations | |
-1092641971 | 2020-3-31 0:00: | SW | No Violations | 0.80 |
-1130975413 | 2013-9-5 0:00:0 | SC | No Violations | |
-1272373844 | 2017-1-5 0:00:0 | SW | No Violations | |
-1334462209 | 2019-11-18 0:00 | SW | No Violations | 0.50 |
-139260464 | 2019-1-14 0:00: | SW | No Violations | 0.70 |
-1469682633 | 2018-3-22 0:00: | SW | No Violations | 0.50 |
-1505371364 | 2020-3-26 0:00: | SW | No Violations | 5.00 |
-1518410216 | 2014-5-16 0:00: | SW | No Violations | |
-1590048479 | 2013-12-17 0:00 | SW | No Violations | |
-1601143129 | 2013-4-18 0:00: | SW | No Violations | |
-1603238546 | 2013-9-16 0:00: | SC | No Violations | |
-1607249832 | 2013-4-23 0:00: | SW | No Violations | |
-1633606046 | 2014-6-10 0:00: | SW | No Violations | |
-1725618463 | 2017-2-15 0:00: | SW | No Violations | |
-1793764185 | 2017-5-4 0:00:0 | SW | No Violations | |
-1852366862 | 2017-6-29 0:00: | SW | No Violations | 0.30 |
-1870941006 | 2013-9-5 0:00:0 | SW | No Violations | |
-1969738249 | 2019-11-4 0:00: | SW | No Violations | 1.00 |
-1978427379 | 2019-7-31 0:00: | SW | No Violations | 0.30 |
-2029611566 | 2013-4-13 0:00: | SW | No Violations | |
-2110500869 | 2020-9-1 0:00:0 | SW | No Violations | |
-2145436391 | 2013-4-9 0:00:0 | SW | No Violations | |
-238973756 | 2020-4-29 0:00: | SW | No Violations | 0.50 |
-277206063 | 2016-9-15 0:00: | SW | No Violations | |
-326682551 | 2013-8-19 0:00: | SW | No Violations | |
-433520653 | 2020-5-6 0:00:0 | SW | No Violations | |
-444706972 | 2017-1-30 0:00: | SW | No Violations | |
-463295380 | 2015-4-25 0:00: | SW | No Violations | |
-471360909 | 2020-3-3 0:00:0 | SW | No Violations | 1.30 |
-535038254 | 2020-5-6 0:00:0 | SW | No Violations | 0.40 |
-577697694 | 2013-10-15 0:00 | SW | No Violations | |
-630573903 | 2015-9-4 0:00:0 | SW | No Violations | |
-810745973 | 2020-8-21 0:00: | SW | No Violations | 0.50 |
-839349100 | 2019-2-11 0:00: | SW | No Violations | |
-953009995 | 2013-4-11 0:00: | SW | No Violations | |
-973539868 | 2013-4-29 0:00: | SW | No Violations | |
0066647115 | 2019-03-13 | Salt Water Injection Well | Violations Noted | I found the injection well not in operation during my inspection. Upon gauging the injection tubing, the reading was above the maximum allowable pressure at 1,090 psi. There was a facility operator on location. I observed no leaks or spills. The proper identification sign is posted. I spoke to the facility operator and instructed him to not operate the injection well until the pressure is below the maximum allowable pressure. A follow-up inspection will be conducted. |
0103291057 | 2015-06-03 | Salt Water Injection Well | No Violations | The well and surface facility were inspected. There were no violations found at the time of inspection. |
0134038713 | 2017-02-28 | Salt Water Injection Well | No Violations | Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 3rd, & 4th quarters of 2016. Please submit the appropriate reports by March 14, 2017 REPORTS RECEIVED 3/6/2017. |
0139260464 | 2019-01-14 | Salt Water Injection Well | No Violations | I was on location to inspect the injection well. I found the access road to the injection well blocked by a vehicle in front of the closed and locked access road gate. I instructed the facility operator to have the vehicle removed and not to block access to the injection well. The facility is in good repair. There was a AIM Services brine truck (#25-564) and a Spirit Services brine truck (#25-562) off-loading on location with the proper identification displayed. |
0184094544 | 2015-12-14 | Salt Water Injection Well | No Violations | I was on location in reference to complaint ID 5197. At this time, the identification sign had not been corrected. I spoke with Joe Townsend, Safety Coordinator for KDA, on location. Mr. Townsend stated the new sign had been order and due to arrive this week. |
0225278534 | 2013-07-01 | Salt Water Injection Well | No Violations | The flow line was pressure tested, using 1080 psi. of pressure. During fifteen minute test period, 10 psi. loss was observed. The line will not be buried. There were no apparent leaks detected. |
0244384091 | 2014-07-25 | Salt Water Injection Well | Violations Noted | An inspection found the well exceeding the maximum allowable injection pressure. The well tender was instructed to slow the pump rate, lowering the pressure by more than 15 psi. on the tubing. The well owner was instructed to put a minimum pressure of 200 psi. on the tubing/casing annulus. |
0277206063 | 2016-09-15 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
0314238672 | 2017-09-20 | Salt Water Injection Well | No Violations | I was on location to inspect the injection well. The well is surrounded by a locked wooden fence. An identification sign is posted on the fence. The UIC facility and diked tank battery is in good repair. There is an identification posted on the facility office building. There are no violations at this time. |
0326682551 | 2013-08-19 | Salt Water Injection Well | No Violations | No violations were found at the time of my inspection. |
0444706972 | 2017-01-30 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations at the time. |
0463295380 | 2015-04-25 | Salt Water Injection Well | No Violations | The purpose of this inspection was to follow-up on a compliance notice for exceeding the maximum allowable injection pressure. The injection pressure was below the maximum allowed. A pressure shut-off switch was installed on the injection line. A meter was recording, both tubing pressure and annular pressure, on a chart. The well was in compliance and allowed to operate. |
0519826056 | 2018-01-12 | Salt Water Injection Well | No Violations | I was on location to inspect the UIC facility. I found the injection well pressure over the maximum allowable pressure by 20 psi. The injection line to the wellhead and gravel around the injection well had oil residue. An identification sign is posted at the well and facility. The fence around the well is secure with a lock. I told the facility operator to immediately reduce the pressure. The facility operator stated the injection has been shut down due to the pressure and the area around the well impacted by the oil residue will be cleaned up. A follow-up inspection will be conducted by 1/18/2018. |
0530076386 | 2016-05-17 | Salt Water Injection Well | No Violations | At the time of my inspection, I found the injection well in production. The well is in good repair. There is a locked wooden fence around the well. An identification sign is posted at the well. The tank battery has nine storage tanks. The off-loading area and pump house are in good repair. The access road is in stable condition with a gate at the entrance.
The equipment on the site consists of the following:
|
0530723686 | 2013-04-10 | Salt Water Injection Well | No Violations | The cement plug was tagged at 4122 feet. The casing and cement plug were pressure tested. The test failed. |
0577697694 | 2013-10-15 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
0595023586 | 2015-02-13 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
0612037210 | 2014-03-18 | Salt Water Injection Well | No Violations | The annulus maybe frozen, preventing an accurate reading. There were no violations at the time of inspection. |
0630573903 | 2015-09-04 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
0695457503 | 2015-12-21 | Salt Water Injection Well | No Violations | I was on location to inspect the injection well and facility. The emergency contact information on the main identification sign located above the office has been corrected. At this time, there are no violations. |
0839349100 | 2019-02-11 | Salt Water Injection Well | Violations Noted | The Division has not received the 2nd & 4th quarter brine disposal fees for 2018. Please forward disposal fees and sheets to the Division by 3/12/2019. |
0843563620 | 2015-01-12 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
0873863014 | 2013-09-03 | Surface Facility Construction | No Violations | Seven inches of concrete was poured over emergency containment vaults. |
0953009995 | 2013-04-11 | Salt Water Injection Well | No Violations | A bridge plug was set, in the well, just above the cement plug. A cement bond log was ran, which showed the top of cement, behind the 4-1/2 inch casing, at 3690 feet. |
0973539868 | 2013-04-29 | Salt Water Injection Well | No Violations | A contractor was drilling out a remedial cement plug within the 4-1/2 inch casing.
My inspection of the well site found no violations. |
0986623649 | 2014-11-20 | Brine Hauler | No Violations | PERFORMED FIELD AUDIT ON BRINE TRUCKS. WITNESSED 1 KEYSTONE CLEARWATER SOLUTIONS TRUCK (UIC # 25-579) LABELED PROPERLY AND APPROVED TO DISPOSE AT THIS SITE. NO TRUCK VIOLATIONS FOUND. |
1027744807 | 2013-07-15 | Salt Water Injection Well | No Violations | The well was in compliance at the time of inspection. |
1032090226 | 2019-02-25 | Salt Water Injection Well | No Violations | I was on location to assess Compliance Notice #124404230. I found the injection well under the maximum allowable pressure. An identification sign is posted. There are no further violations at this time. |
103291057 | 2015-6-3 0:00:0 | SW | No Violations | |
1040400902 | 2018-07-23 | Salt Water Injection Well | No Violations | I found the injection well in operation during my inspection. I observed the fitting coming off of the wellhead has a slow leak and impacting gravel around other surface. There is a locked wooden fence around the wellhead. Identification signs are posted. I instructed the facility operator to repair the leaking fitting and remove all of the impacted gravel. |
1045458556 | 2014-01-31 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
1047860150 | 2015-12-03 | Salt Water Injection Well | No Violations | I was on location in reference to complaint ID 5197. During my inspection, I found an identification sign posted above a window on the office building next to the tank battery. The emergency contact and number were incorrect. There is an identification sign posted at the well with the name and permit number. A locked, wooden fence surrounds the well. I instructed KDA to correct the emergency contact and number immediately. Next, I called and left a message with Ms. Beiersdorfer for a return call. A follow-up inspection will be conducted by 12/10/2015. |
1089262642 | 2017-02-01 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected the previous day. There was a difference of 5 pounds per square inch (psi.) between the tubing pressure and tubing/casing annular pressure.
The purpose of this inspection was to ensure that the well had mechanical integrity. On this day, there was a difference of 40 psi. between the two pressures. Jason Caldwell was instructed to increase the difference to at least 500 psi. by lowering the annular pressure. |
1093948407 | 2015-04-24 | Salt Water Injection Well | No Violations | The purpose of this inspection was to follow-up on a compliance notice issued the day before. On 4/23/15, the well was operating 40 psi. over the maximum allowable injection pressure. At the time of this inspection, the well was operating at 50 psi. over the maximum allowable injection pressure. Matt Kleese was ordered to shut down the injection operation. He was instructed to equip the well with a pressure shut-off switch and an approved form of continuous pressure monitoring. |
1130975413 | 2013-09-05 | Surface Facility Construction | No Violations | The concrete was being poured for a pad under the 400 barrel storage tanks. |
1134873528 | 2020-5-21 0:00: | SW | No Violations | 0.30 |
118143191 | 2020-4-27 0:00: | SW | No Violations | |
1202480719 | 2013-04-26 | Salt Water Injection Well | No Violations | I witnessed the packer installation. The mechanical integrity test could not be done. A leak in the casing will have to be located. |
1239185605 | 2019-04-29 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on April 15th for 2018, Please submit the Form 204 to the Division by 5/29/2019. |
1244042300 | 2019-02-22 | Salt Water Injection Well | Violations Noted | I found the injection well not operating during my inspection. Upon gauging the injection well, the reading for the injection tubing was above the maximum allowable pressure at 1,090 psi. I spoke with facility operator and instructed him to cease all injection operations until the pressure at the injection well has dropped below the maximum allowable pressure. The facility operator stated the injection well has been shut down all morning. There was an AIM brine truck and a CES brine truck off-loading on location with the proper UIC numbers (#25-564 and #25-423) and company information displayed. A follow-up inspection will be conducted by 2/25/2019. |
1244544426 | 2014-12-04 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
1252236703 | 2020-5-18 0:00: | SW | No Violations | 1.00 |
1272373844 | 2017-01-05 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. The pump was operating at the time.
There were no violations found. |
1294841667 | 2020-1-22 0:00: | SW | No Violations | 0.40 |
134038713 | 2017-2-28 0:00: | SW | No Violations | |
1346583843 | 2014-09-11 | Salt Water Injection Well | No Violations | An inspection of the well and injection facility found no violations. |
1348498963 | 2012-09-11 | Production Wells | No Violations | The well owner has applied to convert the well from production to saltwater injection. The well site was inspected as part of a field review. There are no water wells within 300 feet of the well and proposed facility location. The well is located within what may be wetlands. Additional permit requirements may be warranted. |
1352705607 | 2019-11-14 0:00 | SW | No Violations | 0.40 |
1372784403 | 2013-04-19 | Salt Water Injection Well | No Violations | A pressure test was performed, with a pressure of 1295 psi. placed on the casing. During the 15 minute test period, a 50 psi. or 3.9% loss was observed. The test passed with a loss less than 5%. |
1377566923 | 2013-08-23 | Surface Facility Construction | No Violations | The turning lane and entrance is complete. Surface facility construction was started. There were no problems at the time. |
1377618488 | 2013-07-12 | Salt Water Injection Well | Violations Noted | My inspection was accompanied by Andrew Adgate. The well was found operating over the maximum allowable injection pressure.
The operator was instructed to shut down, decrease the tubing pressure, and install a pressure shut-off switch. |
1378656235 | 2014-08-15 | Salt Water Injection Well | No Violations | An inspection of the well and injection facility found no violations. |
1428691037 | 2015-04-08 | Salt Water Injection Well | No Violations | I inspected this salt water injection well as a general, routine status check. The facility is comprised of an aboveground storage tank (AST) battery with 9 210-barrel steel tanks in a common containment pad. Adjacent to the tank impoundment, is a combined maintenance/office/control room. The wellhead is located 320 feet behind (southwest) of the control building. Unloading is executed by attaching 4-inch flex-hose to cam-lock fittings at the pit area and fluids are drained into this open-topped, cement-sided impoundment structure which is underlain by a series of pre-cast cement tank vaults. Fluids are moved from the pit into the battery tanks via fluid pumps with flexible hoses. Secondary containment at the battery is comprised of both cement walls and berms. The berms consist of gravel-ballasted flexible liner over coarse-granular or gravel dike. Areas surrounding the AST impoundment and control building consist of parking and drive areas which are gravel and/or cinder-paved. The areas beyond the footprint of the facility are comprised of woods and low-lying marshy and bog-type terrain. I inspected the low-lying marshy and bog areas surrounding the facility and did not observe any sheens, free-oil, stressed vegetation, or other signs of leakage or spills. I observed the drainage culvert along the roadway at the entrance to be similarly free from staining, sheens, stressed vegetation, or other signs of impact. The well is located in a locked, board-on-board enclosure in a small clearing which is accessed via an unpaved road which travels south behind the facility. I observed connections and fittings at the wellhead to be secure and free from signs of escaping gases, fluids, or signs of leakage. At the time of my inspection, fluid was being off-loaded from a tank truck into the pit. At the time of my inspection, the interior of the impoundment was dry. I observed the horizontal and vertical surface areas of the dike structures to be free from staining. Exterior su |
1450883527 | 2015-12-21 | Salt Water Injection Well | No Violations | I was on location in reference to complaint ID 5197. During my inspection, I found KDA has corrected to emergency contact information on the identification sign above the office. I called and left a message for a return call concerning the corrected identification sign with Mrs. Beiersdorfer. No further violations at this time. |
1464115833 | 2019-10-28 0:00 | SW | No Violations | 1.00 |
1469682633 | 2018-03-22 | Salt Water Injection Well | No Violations | I was on location to inspect the injection well and facility. I found the well not operating on the day of my inspection. The wellhead is in good repair. The wooden fence around the well is locked. I observed no leaks or spills. The proper identification sign is posted. There are no violations at this time. |
1517093427 | 2016-03-15 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
1518410216 | 2014-05-16 | Salt Water Injection Well | No Violations | The pump was not operating at the time. There were no violations found. However, the operator was informed of the two broken gauges found on the well. |
1526563315 | 2018-05-17 | Salt Water Injection Well | Violations Noted | I found the injection well not operating on the day of my inspection. I was unable to gauge the tubing and annulus due to the fittings could not be opened or closed. There is a locked fence surrounding the well. The proper identification is posted at the facility and well. I spoke to Jeremy Caldwell and the facility operator on location to replace the fitting. A compliance notice has been issued.
PAC has until 5/25/2018: Replace the fittings on the tubing and annulus. A follow-up inspection will be conducted. |
1528894337 | 2018-06-13 | Salt Water Injection Well | No Violations | I was on location to assess compliance notice #1526563315. I found new fittings installed at the injection well. There was a facility operator on site. An identification sign is posted. I observed no leaks or spills. There are no violations at this time. |
1532523889 | 2018-07-25 | Salt Water Injection Well | No Violations | I found the impacted gravel from the leaking fitting removed and the fitting repaired per my request. |
1541431155 | 2018-11-05 | Salt Water Injection Well | No Violations | I found the injection well not operating on the day of my inspection. There were facility operators on location. The injection well is surrounded by a locked wooden fence. Identification signs are posted. I observed no spills or leaks. A specific gravity (SG) sample was taken and got a 1.1 reading. A Smith Transport brine truck arrived on location with the proper UIC number displayed (#25-448). |
1549462524 | 2019-02-06 | Salt Water Injection Well | Violations Noted | I found the injection well not operating during my inspection. The pressure on the injection tubing gauged at 1,080 psi, which is above the maximum allowable pressure. The fencing around the injection well was locked. Identification signs are posted. I observed no leaks or spills. I instructed the facility operator not to operate the injection well until the pressure has dropped below the maximum allowable pressure. A compliance notice has been issued. A follow up inspection will be conducted by 2/7/2019. |
1549896688 | 2019-02-11 | Salt Water Injection Well | No Violations | I was on location to assess Compliance Notice #1549462524. I found the injection well pressure below the maximum allowable pressure. There is an identification sign posted. I observed no leaks or spills. There was a Spirit Services brine truck off-loading with the proper UIC number displayed (#25-562). |
1552571716 | 2019-03-14 | Salt Water Injection Well | No Violations | I was on location to assess Compliance Notice #66647115. I found the pressure on the injection well has dropped to 1,080 psi; however, the well was still over the maximum allowable pressure. The injection well was not in operation. There is an identification sign posted. I spoke with the facility operator, who stated the injection well will remain shut down until the pressure drops below the maximum allowable pressure. A follow-up inspection will be conducted. |
1552656164 | 2019-03-15 | Salt Water Injection Well | No Violations | I was on location to assess Compliance Notice #66647115. I found the injection well not in operation during my inspection and below the maximum allowable pressure with a reading of 990 psi. There was a facility operator on location. According to the facility operator, PAC is considering performing maintenance on the well in the near future. I observed no leaks or spills. |
1556717751 | 2019-5-1 0:00:0 | SW | No Violations | 1.40 |
1572372752 | 2019-10-29 0:00 | SW | No Violations | 1.30 |
1573654994 | 2019-11-13 0:00 | SW | No Violations | 0.50 |
1574713072 | 2019-11-25 0:00 | SW | No Violations | 1.50 |
1583335969 | 2020-3-4 0:00:0 | SW | No Violations | 1.30 |
1584559744 | 2020-3-18 0:00: | SW | No Violations | 6.10 |
1584702932 | 2020-3-20 0:00: | SW | No Violations | 5.00 |
1584722346 | 2020-3-20 0:00: | SW | No Violations | 6.00 |
1585070252 | 2020-3-23 0:00: | SW | No Violations | 7.00 |
1585736412 | 2020-8-27 0:00: | SW | No Violations | 1.50 |
1590048479 | 2013-12-17 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
1594144125 | 2020-5-19 0:00: | SW | No Violations | 0.50 |
1597772408 | 2020-8-18 0:00: | SW | No Violations | 1.30 |
1597850071 | 2020-8-19 0:00: | SW | No Violations | 1.00 |
1598276867 | 2020-8-24 0:00: | SW | No Violations | 0.40 |
1601143129 | 2013-04-18 | Salt Water Injection Well | No Violations | A contractor (Timco) was drilling out the remedial cement plug with a power swivel. All conditions were acceptable. |
1603238546 | 2013-09-16 | Surface Facility Construction | No Violations | My inspection of the surface facility construction found no problems. |
1607249832 | 2013-04-23 | Salt Water Injection Well | No Violations | The well was treated, by Nabors Completion & Production Services Co., with 3000 gallons 20% 3M Iron acid.
All conditions were acceptable. |
1633606046 | 2014-06-10 | Salt Water Injection Well | No Violations | An inspection of the well and injection facility found no violations. |
1670892671 | 2015-03-19 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
1698982963 | 2017-10-30 | Salt Water Injection Well | No Violations | I found the UIC facility in good repair on the day of my inspection. The proper identification signs are posted at the facility and well. There are locked wooden fence surrounding the well. I observed no leaks or spills. There are no violations at this time. |
1725618463 | 2017-02-15 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. The pump was operating at the time. There were no violations found. |
1793764185 | 2017-05-04 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
1804968116 | 2016-06-10 | Salt Water Injection Well | No Violations | At the time of my inspection, I found PAC Development has posted new identification signs on the office building and well. There are no violations at this time. |
1834360032 | 2013-10-31 | Salt Water Injection Well | No Violations | A mechanical integrity test was performed on the flow line. A pressure of 1300 psi. was held on the flow line for fifteen minutes. The test passed. |
184094544 | 2015-12-14 0:00 | SW | No Violations | 1.00 |
1852366862 | 2017-06-29 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. The injection well was not in operation on the day of my inspection. A locked wooden fence with an identification sign surrounds the well. There were no violations at the time. |
1863170979 | 2019-11-6 0:00: | SW | No Violations | 1.00 |
1870941006 | 2013-09-05 | Salt Water Injection Well | No Violations | My inspection of the well and injection facility found no violations. |
1926858426 | 2020-5-28 0:00: | SW | No Violations | 1.00 |
1939924559 | 2020-7-8 0:00:0 | SW | No Violations | 1.00 |
1941465683 | 2014-10-30 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
1998212051 | 2014-05-14 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
2009650432 | 2020-3-5 0:00:0 | SW | No Violations | |
2013874041 | 2015-07-14 | Salt Water Injection Well | No Violations | The well and surface facility were inspected. There were no violations found at the time of inspection. |
2016054882 | 2020-7-30 0:00: | SW | No Violations | |
2029564475 | 2015-04-23 | Salt Water Injection Well | Violations Noted | At the time of this inspection, the well was operating at 40 psi. over the maximum allowable injection pressure. Matt Kleese was instructed to shut down the pump and reduce the injection pressure. |
2029611566 | 2013-04-13 | Salt Water Injection Well | No Violations | Previously, the casing was pressure tested twice and failed both times. The top 3,006 feet of 4-1/2 inch casing were replaced with new casing on a rubber sealed patch.
Two additional tests were conducted. The first test used a pressure of 1280 psi. on the tubing/casing annulus. The first attempt failed with a 180 psi. loss in fifteen minutes. A leaking fitting was tightened. A second test used a pressure of 1540 psi. on the tubing/casing annulus. The second attempt failed with a 200 psi. loss in fifteen minutes. |
2035829478 | 2020-6-9 0:00:0 | SW | No Violations | 1.30 |
2102923595 | 2013-04-30 | Salt Water Injection Well | No Violations | A mechanical integrity test was performed with a pressure of 1150 psi. on the tubing-casing annulus. There was a loss of 30 psi. observed during the 15 minute test period. The well passed with a 2.6% loss in pressure. |
2108350838 | 2019-12-30 0:00 | SW | No Violations | 0.50 |
2112900745 | 2018-02-16 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 4th quarter of 2017 . Please submit the appropriate reports by March 17, 2018. FEES AND REPORTS RECEIVED 3/7/2018. |
2141757103 | 2020-3-26 0:00: | SW | No Violations | 2.50 |
2145436391 | 2013-04-09 | Salt Water Injection Well | No Violations | The well was plugged back to the Newburg. The initial total depth was tagged at 4487 feet. A string of 2-7/8 inch tubing was ran to 4380 feet. 25 sacks of Class-A cement, with 5 lb. of Gilsonite per sack, were pumped across the Clinton perforations. The well was reverse circulated at 4117 feet. The cement operation and well site conditions were acceptable. |
225278534 | 2013-7-1 0:00:0 | SW | No Violations | |
244384091 | 2014-7-25 0:00: | SW | No Violations | |
314238672 | 2017-9-20 0:00: | SW | No Violations | 0.40 |
519826056 | 2018-1-12 0:00: | SW | No Violations | 0.50 |
530076386 | 2016-5-17 0:00: | SW | No Violations | 0.30 |
530723686 | 2013-4-10 0:00: | SW | No Violations | |
561581921 | 2019-11-5 0:00: | SW | No Violations | 0.50 |
58946072 | 2019-6-10 0:00: | SW | No Violations | 0.30 |
595023586 | 2015-2-13 0:00: | SW | No Violations | |
612037210 | 2014-3-18 0:00: | SW | No Violations | |
66647115 | 2019-3-13 0:00: | SW | No Violations | |
671207208 | 2020-3-5 0:00:0 | SW | No Violations | 0.60 |
675379256 | 2020-8-26 0:00: | SW | No Violations | 0.60 |
695457503 | 2015-12-21 0:00 | SW | No Violations | 1.00 |
843563620 | 2015-1-12 0:00: | SW | No Violations | |
873863014 | 2013-9-3 0:00:0 | SC | No Violations | |
986623649 | 2014-11-20 0:00 | BH | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0066647115 | US-OH-127545 | 2019-05-21 | 9-3-07(D) | Exceeding maximum allowable injection pressure |
0244384091 | US-OH-122485 | 2014-10-06 | Exceeding maximum allowable injection pressure | |
0839349100 | US-OH-129547 | 2019-04-08 | Failure to report disposal fees | |
1239185605 | US-OH-106375 | 2019-05-09 | Failure to file salt water injection annual report | |
1244042300 | US-OH-106516 | 2019-03-06 | 9-3-07(D) | Exceeding maximum allowable injection pressure |
1377618488 | US-OH-111193 | 2013-08-27 | Exceeding maximum allowable injection pressure | |
1526563315 | US-OH-114604 | 2018-07-17 | 9-3-05(A)3 | Violation of injection tubing/fitting requirements |
1549462524 | US-OH-115040 | 2019-02-13 | 9-3-07(D) | Exceeding maximum allowable injection pressure |
2029564475 | US-OH-120635 | 2015-10-15 | Exceeding maximum allowable injection pressure | |
2112900745 | US-OH-121612 | 2018-03-27 | NONE | Failure to report disposal fees |
For data sources see[9]