{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.24,"lon":-80.88,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Warren Township | |
Operator Name: EVERFLOW EASTERN PARTNERS LP | |
Well Pad ID: | |
Farm/Lease Name: WARREN TWP COMMUNITY CENTER UNIT | |
License Status: Producing | |
License Date: 1989-01-13 | |
Spud Date: 1989-01-15 | |
Spud Drilling Contractor: CUBBY DRLG | |
Final Drill Date: 1989-01-20 | |
Well Total Depth: 4602.00 ft | |
Configuration: Vertical | |
Latitude: 41.240000 | |
Longitude: -80.880000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1989-01-13 | Issued Date 1/13/89 Expired Date 1/13/90 Acres 0060368 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04602 Proposed Drill Depth 04602 |
Original Spud | 1989-01-15 | |
Completed | 1989-01-20 | |
Reached Total Depth | 1989-01-20 | |
CO | 1989-01-31 | 84 EVERFLOW EASTERN PTNS L P GeoDate 1/13/89 |
Completion Report Received | 1989-02-07 | |
Construction Permit Expires | 1990-01-13 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 4356 | 4461 | 46 |
4356 | 4461 | 46 | |
4356 | 4461 | 46 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 120260 Gal | 100000 | FRAC:SAND/WATER |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-797903040 | 2012-8-28 0:00: | UP | No Violations | 0.50 |
0797903040 | 2012-08-28 | UrbanProduction Wells | No Violations | On 8/28/2012, I conducted an urban production well inspection status check. My inspection found the well equipped with a plunger lift unit (rabbit) that was surrounded by a chain link fence with no lock. The tank battery was surrounded by a chain link fence and contained one 100 barrel oil storage tank, one 50 barrel brine storage tank, a separator, and the proper identification posted. I called Strawn Oil Service and asked for the well tender to put a lock on the gate at the well head by 8/29/2012, which is located next to a playground and two little league baseball fields. I will conduct a follow-up inspection. |
1346763143 | 2012-09-04 | UrbanProduction Wells | No Violations | I conducted a compliance follow-up inspection and found the well tender placed a lock on the gate at the well. Inspection passed. |
1425983537 | 2015-02-25 | UrbanProduction Wells | No Violations | I was on location for a status check. During my inspection, I found the well in production. The well was equipped with a plunger lift assembly. The tank battery consisted of a 100 barrel production tank, a 50 barrel brine tank and a mechanical separator. A dike surrounded the tank battery. Identification signs were posted at the tank battery and well. There was a plug on the load line. Locked, chain link fences with barb wire surrounded the tank battery and well. The lease road was in stable condition. The well was placed into production prior to House Bill 278. |
For data sources see[9]