Well ID: 34-155-23344 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.25,"lon":-80.77,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR | |
Well Pad ID: | |
Farm/Lease Name: KELLING UNIT | |
License Status: Producing | |
License Date: 1990-05-15 | |
Spud Date: 1990-05-15 | |
Spud Drilling Contractor: SHERMAN DRLG | |
Final Drill Date: 1990-05-19 | |
Well Total Depth: 4594.00 ft | |
Configuration: Vertical | |
Latitude: 41.250000 | |
Longitude: -80.770000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1990-05-15 | 2456 SIMCO EXPLORATION CORP GeoDate 5/15/90 |
Oil and Gas | 1990-05-15 | Issued Date 5/15/90 Expired Date 5/15/91 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04594 Proposed Drill Depth 04594 |
Original Spud | 1990-05-15 | CHG. IN UNIT/AC. 7-25-92 |
Completed | 1990-05-19 | CHG. IN UNIT/AC. 7-25-92 |
Reached Total Depth | 1990-05-19 | CHG. IN UNIT/AC. 7-25-92 |
Completion Report Received | 1990-11-13 | CHG. IN UNIT/AC. 7-25-92 |
Construction Permit Expires | 1991-05-15 | CHG. IN UNIT/AC. 7-25-92 |
Record Last Modified | 2017-02-15 | CHG. IN UNIT/AC. 7-25-92 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 4383 | 4526 | 0 |
4383 | 4526 | 0 | |
2006-09-11 | 4402 | 4524 | 33 |
4402 | 4524 | 33 | |
4383 | 4526 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 74516 Gal | 60000 | FRAC:WATER/SAND |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1068265320 | 2014-12-2 0:00: | UP | No Violations | 0.50 |
-2076010872 | 2012-10-1 0:00: | UP | No Violations | |
0000003021 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 6/12/91 INSPECTOR JERRY KOHL DATE 06/1219/91 DATA FROM OLD VAX INFO | |
1068265320 | 2014-12-02 | UrbanProduction Wells | No Violations | I was on location for a status check. During my inspection, I found the well in production. The well was equipped with a plunger lift assembly. There was a domestic gas line off of the 4.5 casing. The tank battery consisted of three, 100 barrel production tanks, a 50 barrel brine tank and two separators. A dike surrounded the tank battery. Identification signs were posted. A bull plug was installed on the load line. The lease road in stable condition. The well was placed into production prior to House Bill 278. |
1481311384 | 2016-12-08 | UrbanProduction Wells | No Violations | At time of my inspection, I found the well in production. The well is equipped with a plunger lift assembly. The ball valve on the tubing is open. The diked tank battery has four (4) storage tanks, two (2) separators and a volume bottle. Identification signs are posted at the well and tank battery. Chain link fences surround the tank battery and well. The access road is in good repair and shared with permit 2-3505. A Dominion master meter is near the access road entrance surrounded by a chain link fence.
The equipment on the site consists of the following:
|
1689230558 | 2019-10-7 0:00: | UP | No Violations | |
2076010872 | 2012-10-01 | UrbanProduction Wells | No Violations | I conducted an urban production well inspection status check. My inspection found the well surrounded by a chain link fence and equipped with a plunger lift unit that was in good condition. The tank battery was surrounded by a chain link fence and contained three, 100 barrel oil storage tanks, one, 50 barrel brine storage tank, two separators, and the proper identification. I noticed no visible spills or leaks. The lease road and tank battery are shared with permit number 2-3505. There are no violations at this time. |
3021 | PL | No Violations |
For data sources see[9]