Well ID: 34-155-23354 | |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: ERIC PETROLEUM CORP | |
Well Pad ID: | |
Farm/Lease Name: SCHRADER | |
License Status: Producing | |
License Date: 1990-07-16 | |
Spud Date: 1990-07-25 | |
Spud Drilling Contractor: CUBBY DRLG | |
Final Drill Date: 1990-07-29 | |
Well Total Depth: 4844.00 ft | |
Configuration: Vertical | |
Latitude: 41.170000 | |
Longitude: -80.830000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1990-07-16 | Issued Date 7/16/90 Expired Date Acres 0046461 Tool Type RTAF Proposed Formation CLINTON Proposed Depth Proposed Drill Depth |
Original Spud | 1990-07-25 | |
Completed | 1990-07-29 | |
Reached Total Depth | 1990-07-29 | |
CO | 1990-09-27 | 1100 GM/DELPHI PACKARD ELEC. GeoDate 7/16/90 |
Completion Report Received | 1990-11-23 | |
Construction Permit Expires | 1991-07-16 | |
CO | 1996-07-11 | 4884 EASTERN STATES OIL & GAS GeoDate 7/16/90 |
Change of Owner | 2005-06-07 | Operator changed from 4884, EASTERN STATES OIL & GAS INC to 7849, NCL NATURAL RESOURCES LLC |
Change of Owner | 2017-02-21 | Operator changed from 7849, NCL NATURAL RESOURCES LLC to 5054, ERIC PETROLEUM CORP |
Record Last Modified | 2017-02-21 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 4566 | 4711 | 0 |
4566 | 4711 | 0 | |
2006-09-11 | 4624 | 4664 | 56 |
4624 | 4664 | 56 | |
4566 | 4711 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1477 Bbl | 60000 | FRAC:WATER/SAND | ||
ACID | 25 | 300 Gal | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1992 | GM/DELPHI PACKARD ELEC. | 22175.00 | 131.00 | 365 |
1993 | GM/DELPHI PACKARD ELEC. | 20398.00 | 162.00 | 365 |
1994 | GM/DELPHI PACKARD ELEC. | 16524.00 | 57.00 | 365 |
1995 | GM/DELPHI PACKARD ELEC. | 14571.00 | 67.00 | 365 |
1996 | EASTERN STATES OIL & GAS INC | 13801.00 | 0.00 | 365 |
1997 | EASTERN STATES OIL & GAS INC | 8899.00 | 98.00 | 365 |
1998 | EASTERN STATES OIL & GAS INC | 12503.00 | 0.00 | 365 |
1999 | EASTERN STATES OIL & GAS INC | 11775.00 | 46.00 | 365 |
2000 | EASTERN STATES OIL & GAS INC | 11062.00 | 0.00 | 365 |
2001 | EASTERN STATES OIL & GAS INC | 10260.00 | 0.00 | 365 |
2002 | EASTERN STATES OIL & GAS INC | 6806.00 | 60.00 | 365 |
2003 | EASTERN STATES OIL & GAS INC | 3788.00 | 0.00 | 365 |
2004 | EASTERN STATES OIL & GAS INC | 3564.00 | 0.00 | 366 |
2005 | EQUITABLE PRODUCTION COMPANY | 1260.00 | 0.00 | 151 |
2006 | NCL NATURAL RESOURCES LLC | 4097.00 | 0.00 | 365 |
2007 | NCL NATURAL RESOURCES LLC | 4986.00 | 0.00 | 365 |
2008 | NCL NATURAL RESOURCES LLC | 4746.00 | 0.00 | 365 |
2009 | NCL NATURAL RESOURCES LLC | 4062.00 | 0.00 | 365 |
2010 | NCL NATURAL RESOURCES LLC | 4445.00 | 46.00 | 365 |
2011 | NCL NATURAL RESOURCES LLC | 4597.00 | 0.00 | 365 |
2012 | NCL NATURAL RESOURCES LLC | 4540.00 | 0.00 | 366 |
2013 | NCL NATURAL RESOURCES LLC | 4581.00 | 0.00 | 365 |
2014 | NCL NATURAL RESOURCES LLC | 4666.00 | 0.00 | 365 |
2015 | NCL NATURAL RESOURCES LLC | 3298.00 | 0.00 | 365 |
2016 | NCL NATURAL RESOURCES LLC | 4420.00 | 0.00 | 365 |
2017 | ERIC PETROLEUM CORP | 2800.00 | 0.00 | 365 |
2018 | ERIC PETROLEUM CORP | 3361.00 | 0.00 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0291557398 | 2013-10-25 | UrbanProduction Wells | No Violations | My inspection found the well in production. The well was equipped with a plunger lift unit. The tank battery contained a 100 barrel production tank and a heat, treated separator. The dike met containment requirements and surrounded the production tank. All production equipment spacing was incompliance. There was a domestic gas line coming off the flow line at the separator. A identification sign was properly posted. The lease road was in good condition. This well was placed into production prior to House Bill 278. |
0856779740 | 2004-01-16 | Preliminary Restoration | No Violations | Restoration approved . |
291557398 | 2013-10-25 0:00 | UP | No Violations | 0.50 |
856779740 | 2004-1-16 0:00: | PL | No Violations |