Well Details

Well ID: 34-155-23373
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Weathersfield Township
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR
Well Pad ID:
Farm/Lease Name: GALLO
License Status: Producing
License Date: 1990-12-20
Spud Date: 1990-12-21
Spud Drilling Contractor: ARMSTRONG DRLG
Final Drill Date: 1990-12-28
Well Total Depth: 5039.00 ft
Configuration: Vertical
Latitude: 41.150000
Longitude: -80.730000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1990-09-17 2456 SIMCO EXPLORATION CORP GeoDate 9/17/90
Oil and Gas 1990-09-17 Issued Date 9/17/90 Expired Date 9/17/91 Acres 0043189 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
CO 1990-12-20 2456 SIMCO EXPLORATION CORP GeoDate 12/20/90
Oil and Gas 1990-12-20 Issued Date 9/17/90 Expired Date 9/17/90 Acres 0043699 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 05039 Proposed Drill Depth 05039
Original Spud 1990-12-20 RL 12/22/1990
Completed 1990-12-28 RL 12/22/1990
Reached Total Depth 1990-12-28 RL 12/22/1990
Completion Report Received 1991-03-14 RL 12/22/1990
Construction Permit Expires 1991-09-17 RL 12/22/1990
Record Last Modified 2017-02-15 RL 12/22/1990

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4856 4990 0
4856 4990 0
2006-09-11 4868 4930 24
4868 4930 24
4856 4990 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2100 Bbl 60000 N2 FOAM FRAC
N2 0 180 Mscf 0
ACID 0 500 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1991 OHIO VALLEY ENERGY SYSTEMS COR 11998.00 338.00 259
1992 OHIO VALLEY ENERGY SYSTEMS COR 9930.00 139.00 365
1993 OHIO VALLEY ENERGY SYSTEMS COR 10651.00 97.00 365
1994 OHIO VALLEY ENERGY SYSTEMS COR 8124.00 70.00 365
1995 OHIO VALLEY ENERGY SYSTEMS COR 6934.00 69.00 365
1996 OHIO VALLEY ENERGY SYSTEMS COR 6401.00 56.00 364
1997 OHIO VALLEY ENERGY SYSTEMS COR 5462.00 0.00 364
1998 OHIO VALLEY ENERGY SYSTEMS COR 4479.00 57.00 365
1999 OHIO VALLEY ENERGY SYSTEMS COR 4448.00 0.00 365
2000 OHIO VALLEY ENERGY SYSTEMS COR 3978.00 55.00 365
2001 OHIO VALLEY ENERGY SYSTEMS COR 4072.00 0.00 364
2002 OHIO VALLEY ENERGY SYSTEMS COR 3771.00 0.00 364
2003 OHIO VALLEY ENERGY SYSTEMS COR 3463.00 0.00 364
2004 OHIO VALLEY ENERGY SYSTEMS COR 2896.00 0.00 294
2005 OHIO VALLEY ENERGY SYSTEMS COR 3081.00 0.00 364
2006 OHIO VALLEY ENERGY SYSTEMS COR 2796.00 62.00 364
2007 OHIO VALLEY ENERGY SYSTEMS COR 1980.00 0.00 364
2008 OHIO VALLEY ENERGY SYSTEMS COR 2623.00 0.00 365
2009 OHIO VALLEY ENERGY SYSTEMS COR 2981.00 57.00 365
2010 OHIO VALLEY ENERGY SYSTEMS COR 1697.00 0.00 365
2011 OHIO VALLEY ENERGY SYSTEMS COR 1968.00 0.00 318
2012 OHIO VALLEY ENERGY SYSTEMS COR 2235.00 0.00 366
2013 OHIO VALLEY ENERGY SYSTEMS COR 2698.00 0.00 365
2014 OHIO VALLEY ENERGY SYSTEMS COR 1066.00 0.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 3333.00 0.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 1235.00 0.00 116
2017 OHIO VALLEY ENERGY SYSTEMS COR 1810.00 0.00 365
2018 OHIO VALLEY ENERGY SYSTEMS COR 2783.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1991 OHIO VALLEY ENERGY SYSTEMS COR Brine 1978 259
1992 OHIO VALLEY ENERGY SYSTEMS COR Brine 39 365
1993 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
1994 OHIO VALLEY ENERGY SYSTEMS COR Brine 32 365
1995 OHIO VALLEY ENERGY SYSTEMS COR Brine 30 365
1996 OHIO VALLEY ENERGY SYSTEMS COR Brine 20 364
1997 OHIO VALLEY ENERGY SYSTEMS COR Brine 35 364
1998 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
1999 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2000 OHIO VALLEY ENERGY SYSTEMS COR Brine 25 365
2001 OHIO VALLEY ENERGY SYSTEMS COR Brine 364
2002 OHIO VALLEY ENERGY SYSTEMS COR Brine 13 364
2003 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 364
2004 OHIO VALLEY ENERGY SYSTEMS COR Brine 294
2005 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 364
2006 OHIO VALLEY ENERGY SYSTEMS COR Brine 5 364
2007 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 364
2008 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2009 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2010 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2011 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 318
2012 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 366
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 30 365
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 14 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 116
2017 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2018 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0182066828 2004-03-10 Preliminary Restoration No Violations Restoration approved .
1397136086 2014-02-20 UrbanProduction Wells No Violations I responded to a requested inspection from Rick Little of Ohio Valley concerning the landowner not allowing the well tender on the property to perform maintenance on the well and tank battery. My inspection found the well in production; however, the flow line valve at the plunger lift unit was closed. Two domestic gas lines came off the 4.5 casing. The tank battery consisted of a 100 barrel production tank, a 30 barrel brine tank, and a separator. The dike was weathered and not capable of meeting containment requirements. The was a tree and small shrubs in the dike. A bull plug was installed on the load line. Access to the tank battery was the driveway and parking area for Global Oil & Gas Services. While on location the business/landowner, Rick Glass, arrived on site. I asked the landowner about the situation with not allowing the well tender on location to service the well. Rick Glass stated the well tender was accessing the tank battery illegally because the current location of the tank battery was in the wrong location. Also, he stated the access road should be coming off of McDonald Ave., which is east of the well and tank battery. Rick had safety concerns with the ladder not being properly bolted to the tank and that the bottom of the steps were off the ground; he did not want to be held liable for any injuries that may occur as a result of the current location of the tank battery. Rick stated the entire matter concerning the tank battery and the access road was being handled by his lawyer.
1401464224 2014-05-30 Production Wells No Violations I received a phone call from Rick Skidmore asking me to inspect this well for contamination issues. While on location I spoke with both the landowners and the well tender. The well was serviced the previous day and the company had spread peat sorb around the well to absorb the oil and brine that was caused due to the maintenance performed. The 100 BBL production tank had a thin coat of oil down one side of the tank from unloading the well into the tank. I instructed the crew on location from the company to wipe down the tank and clean up any contamination around the well. I spoke with my supervisor Tom Hill about the issue and he was in contact with the company. A meeting with the company man from Ohio valley was scheduled to discuss issues on location.
1401902503 2014-06-03 UrbanProduction Wells No Violations

The well is a plunger lift system that has been recently worked over. During the work over the operator had placed rig mats down to protect the lawn. Mr. Glass was concerned about the oil spray around the wellhead from the work over and it happening again. Oil spray from that work over has been cleaned up. The well had minor gas leaking from between the 4.5 inch and tubing. The following actions need taken at the well site: The dike around the production equipment needs completed. Install fencing around the tank battery and well. Locks maintained on all man doors, valves and hatches. Install proper support under the ladder to the production tank. Trees and brush trimmed back away from the tank battery. Packing around the tubing needs tightened. During future work over operations a liner will be placed under the service rig for spill control. Requested actions need completed by June 27, 2014.

1418317870 2014-12-09 UrbanProduction Wells No Violations I was on location for a follow-up inspection. During my inspection, I found a new dike built. There were new, locked chain link fences with barb wire around the production equipment and well. Identification signs were posted at the tank battery and well. Cement blocks were placed at the base of the ladder on the production tank.
182066828 2004-3-10 0:00: PL No Violations

For data sources see[9]

References