Well Details

Well ID: 34-155-23501
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Howland Township
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR
Well Pad ID:
Farm/Lease Name: BELIEVERS CHRISTIAN UNIT
License Status: Producing
License Date: 1992-11-30
Spud Date: 1993-01-08
Spud Drilling Contractor: [[JL COATS [COATS-GOFF]]]
Final Drill Date: 1993-01-25
Well Total Depth: 4705.00 ft
Configuration: Directional
Latitude: 41.260000
Longitude: -80.780000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1992-11-30 2456 SIMCO EXPLORATION CORP GeoDate 11/30/92
Oil and Gas 1992-11-30 Issued Date 11/30/92 Expired Date 11/30/93 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04705 Proposed Drill Depth 04705
Original Spud 1992-12-30
Completed 1993-01-25
Reached Total Depth 1993-01-25
Completion Report Received 1993-11-23
Construction Permit Expires 1993-11-30
Correction to Well 2001-01-12 CHANGE IN LOCATION INFORMATION: SOURCE= "AS DRILLED SURVEY"; SURFACE INFORMATION: FOOTAGE= 1285'NL & 681'WL OF LOT 9; X= 2,470,317 AND Y= 585,830. TARGET INFORMATION: FOOTAGE= 1397'NL & 915'WL OF LOT 9; X= 2,470,551 AND Y= 585,718.
Record Last Modified 2019-06-14

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4474 0
4474 0
2006-09-11 4481 4598 3
4481 4598 3
4474 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 1000 Gal 0
N2 0 220 Mscf 0
H2O 0 2400 Bbl 80000 FRAC W/2400 BW,800 SX SND AND 220

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1993 OHIO VALLEY ENERGY SYSTEMS COR 2013.00 350.00 16
1994 OHIO VALLEY ENERGY SYSTEMS COR 34976.00 443.00 365
1995 OHIO VALLEY ENERGY SYSTEMS COR 28378.00 185.00 308
1996 OHIO VALLEY ENERGY SYSTEMS COR 10824.00 150.00 308
1997 OHIO VALLEY ENERGY SYSTEMS COR 16692.00 167.00 364
1998 OHIO VALLEY ENERGY SYSTEMS COR 8729.00 103.00 315
1999 OHIO VALLEY ENERGY SYSTEMS COR 23746.00 140.00 365
2000 OHIO VALLEY ENERGY SYSTEMS COR 14834.00 55.00 365
2001 OHIO VALLEY ENERGY SYSTEMS COR 13962.00 66.00 364
2002 OHIO VALLEY ENERGY SYSTEMS COR 12288.00 76.00 364
2003 OHIO VALLEY ENERGY SYSTEMS COR 14308.00 0.00 364
2004 OHIO VALLEY ENERGY SYSTEMS COR 11001.00 0.00 364
2005 OHIO VALLEY ENERGY SYSTEMS COR 3856.00 72.00 336
2006 OHIO VALLEY ENERGY SYSTEMS COR 7212.00 0.00 336
2007 OHIO VALLEY ENERGY SYSTEMS COR 5784.00 56.00 322
2008 OHIO VALLEY ENERGY SYSTEMS COR 6174.00 61.00 365
2009 OHIO VALLEY ENERGY SYSTEMS COR 6102.00 0.00 365
2010 OHIO VALLEY ENERGY SYSTEMS COR 4565.00 60.00 365
2011 OHIO VALLEY ENERGY SYSTEMS COR 4157.00 0.00 365
2012 OHIO VALLEY ENERGY SYSTEMS COR 7211.00 0.00 361
2013 OHIO VALLEY ENERGY SYSTEMS COR 9300.00 0.00 365
2014 OHIO VALLEY ENERGY SYSTEMS COR 7047.00 0.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 6885.00 0.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 5479.00 0.00 365
2017 OHIO VALLEY ENERGY SYSTEMS COR 6566.00 0.00 365
2018 OHIO VALLEY ENERGY SYSTEMS COR 6781.00 72.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1993 OHIO VALLEY ENERGY SYSTEMS COR Brine 2180 16
1994 OHIO VALLEY ENERGY SYSTEMS COR Brine 25 365
1995 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 308
1996 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 308
1997 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 364
1998 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 315
1999 OHIO VALLEY ENERGY SYSTEMS COR Brine 35 365
2000 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2001 OHIO VALLEY ENERGY SYSTEMS COR Brine 364
2002 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 364
2003 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 364
2004 OHIO VALLEY ENERGY SYSTEMS COR Brine 364
2005 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 336
2006 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 336
2007 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 322
2008 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2009 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2010 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2011 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2012 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 361
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2016 OHIO VALLEY ENERGY SYSTEMS COR Brine 51 365
2017 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365
2018 OHIO VALLEY ENERGY SYSTEMS COR Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-105390778 2019-10-7 0:00: UP No Violations
-1437609407 2012-11-26 0:00 UP No Violations 0.50
-2074822674 2004-2-25 0:00: PL No Violations
-2128074157 2003-3-12 0:00: PW No Violations
-978399070 2016-11-28 0:00 UP No Violations 0.50
0978399070 2016-11-28 UrbanProduction Wells No Violations At time of my inspection, I found the well in production. The well is equipped with a plunger lift assembly. The diked tank battery has two (2) storage tanks, sales line with production chart and a separator. Identification signs are posted at the tank battery and well. The load line is secure with a plug. Locked wooden fences surround the well and tank battery. The access road is the paved parking lot for the Church.

The equipment on the site consists of the following:



1437609407 2012-11-26 UrbanProduction Wells No Violations I completed an urban production well inspection status check. My inspection found the well equipped with a plunger lift unit that was surrounded by a board-on-board fence with the proper identification sign. The tank battery was surrounded by a board-on-board fence and contained one, 100 barrel oil storage tank, one, 50 barrel brine storage tank, a separator, and the proper identification sign. I noticed no visible spills or leaks. The lease road was in the parking lot for the Believers Christian Church.
2074822674 2004-02-25 Preliminary Restoration No Violations Restoration approved .
2128074157 2003-03-12 Production Wells No Violations W.W. investigation [ Beetle/ Swegan ] Inspection showed no violations .

For data sources see[9]