If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-23505 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.25,"lon":-80.77,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: OHIO VALLEY ENERGY SYSTEMS COR | |
Well Pad ID: | |
Farm/Lease Name: BLESSED SACRAMENT UNIT | |
License Status: Producing | |
License Date: 1992-12-04 | |
Spud Date: 1992-12-30 | |
Spud Drilling Contractor: PEP DRLG | |
Final Drill Date: 1993-01-18 | |
Well Total Depth: 4997.00 ft | |
Configuration: Directional | |
Latitude: 41.250000 | |
Longitude: -80.770000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1992-12-04 | 2456 SIMCO EXPLORATION CORP GeoDate 12/4/92 |
Oil and Gas | 1992-12-04 | Issued Date 12/4/92 Expired Date 12/4/93 Acres 0051111 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04997 Proposed Drill Depth 04997 |
Original Spud | 1992-12-31 | CORR. LOC. 6-15-96 |
Completed | 1993-01-18 | CORR. LOC. 6-15-96 |
Reached Total Depth | 1993-01-18 | CORR. LOC. 6-15-96 |
Completion Report Received | 1993-11-23 | CORR. LOC. 6-15-96 |
Construction Permit Expires | 1993-12-04 | CORR. LOC. 6-15-96 |
Record Last Modified | 2017-02-15 | CORR. LOC. 6-15-96 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 4844 | 0 | |
4844 | 0 | ||
2006-09-11 | 4862 | 4984 | 3 |
4862 | 4984 | 3 | |
4844 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
N2 | 0 | 220 Mscf | 0 | |||
ACID | 0 | 1000 Gal | 0 | |||
H2O | 0 | 2400 Bbl | 80000 | FRAC W/2400 BW,800 SX SAND AND 220 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-615643385 | 2019-10-7 0:00: | UP | No Violations | |
0000016718 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 6/18/96 INSPECTOR KEITH WHITE DATE 06/1819/96 DATA FROM OLD VAX INFO | |
0217228777 | 2012-10-01 | UrbanProduction Wells | No Violations | I conducted an urban production well inspection status check. My inspection found the well equipped with a plunger lift unit with an approximately 18 diameter oil spill. The tank battery was surrounded by a chain link fence and contained three, 100 barrel oil storage tanks, one, 50 barrel brine storage tank, two separators, and the proper identification sign. I noticed no visible spills or leaks. The lease road and tank battery are shared with permit number 2-3344. I called Don Nething at 330-283-5758 and asked for the oil spill to be cleaned up and to install an identification sign at the wellhead. I will conduct a follow-up inspection by 10/8/2012. |
0256196892 | 2012-10-31 | UrbanProduction Wells | No Violations | I completed a follow-up inspection. My inspection found the proper identification sign posted at the wellhead, the oil leak cleaned up, and new gravel spread around the wellhead. |
0278461113 | 2014-12-02 | UrbanProduction Wells | No Violations | I was on location for a status check. During my inspection, I found the well in production. The well was equipped with a plunger lift assembly. The well was surrounded by a chain link fence. There was a domestic gas line off of the 4.5 casing. The tank battery consisted of three, 100 barrel production tanks, a 50 barrel brine tank and two separators. A dike surrounded the tank battery. Identification signs were posted. A bull plug was installed on the load line. The lease road in stable condition. The well was placed into production prior to House Bill 278. |
0424697529 | 2016-12-08 | UrbanProduction Wells | No Violations
-3344. A Dominion master meter is near the access road entrance surrounded by a chain link fence. The equipment on the site consists of the following:
| |
16718 | PL | No Violations | ||
217228777 | 2012-10-1 0:00: | UP | No Violations | 0.50 |
256196892 | 2012-10-31 0:00 | UP | No Violations | 0.50 |
278461113 | 2014-12-2 0:00: | UP | No Violations | 0.50 |
424697529 | 2016-12-8 0:00: | UP | No Violations | 0.50 |
For data sources see[9]