X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-23663

Well Details

Well ID: 34-155-23663
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Weathersfield Township
Operator Name: BOBCAT WELL & PIPELINE LLC
Well Pad ID:
Farm/Lease Name: PARKER UNIT
License Status: Producing
License Date: 1997-09-25
Spud Date: 1997-10-27
Spud Drilling Contractor: MOHAWK DRLG
Final Drill Date: 1997-11-03
Well Total Depth: 4801.00 ft
Configuration: Vertical
Latitude: 41.170000
Longitude: -80.770000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 1997-09-25 Proposed Formations:CLINTON, Issued Date:9/25/97, Expired Date:9/25/98 6:00:00 AM, Drilling unit acres:41.58, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 1997-10-27 RBDMS Rec
Completed 1997-11-03 RBDMS Rec
Reached Total Depth 1997-11-03 RBDMS Rec
Completion Report Received 1998-02-27 RBDMS Rec
Construction Permit Expires 1998-09-25 RBDMS Rec
Change of Owner 2015-01-27 Operator changed from 2651, D & L ENERGY INC to 9426, BOBCATE WELL AND PIPELINE LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1998-05-12 4654 4730 45
4654 4730 45
4654 4730 45

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 7 2381 Bbl 80000 500 GALLONS FE ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1998 D & L ENERGY INC 11423.00 335.00 365
1999 D & L ENERGY INC 33922.00 358.00 365
2000 D & L ENERGY INC 16045.00 109.00 365
2001 D & L ENERGY INC 6229.00 0.00 365
2002 D & L ENERGY INC 7386.00 48.00 365
2003 D & L ENERGY INC 7602.00 60.00 365
2004 D & L ENERGY INC 5666.00 0.00 365
2005 D & L ENERGY INC 12265.00 138.00 365
2006 D & L ENERGY INC 10146.00 141.00 365
2007 D & L ENERGY INC 8337.00 125.00 365
2008 D & L ENERGY INC 9646.00 72.00 366
2009 D & L ENERGY INC 10805.00 96.00 365
2010 D & L ENERGY INC 9616.00 0.00 365
2011 D & L ENERGY INC 8246.00 55.00 0
2012 D & L ENERGY INC 6966.00 0.00 365
2013 D & L ENERGY INC 6796.00 93.00 365
2014 D & L ENERGY INC 5138.00 0.00 365
2015 BOBCAT WELL & PIPELINE LLC 3631.00 0.00 345
2016 BOBCAT WELL & PIPELINE LLC 5834.00 0.00 347
2017 BOBCAT WELL & PIPELINE LLC 4192.00 37.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1998 D & L ENERGY INC Brine 129 365
1999 D & L ENERGY INC Brine 115 365
2000 D & L ENERGY INC Brine 0 365
2001 D & L ENERGY INC Brine 0 365
2002 D & L ENERGY INC Brine 0 365
2003 D & L ENERGY INC Brine 0 365
2004 D & L ENERGY INC Brine 0 365
2005 D & L ENERGY INC Brine 0 365
2006 D & L ENERGY INC Brine 0 365
2007 D & L ENERGY INC Brine 0 365
2008 D & L ENERGY INC Brine 0 366
2009 D & L ENERGY INC Brine 0 365
2010 D & L ENERGY INC Brine 51 365
2011 D & L ENERGY INC Brine 0
2012 D & L ENERGY INC Brine 0 365
2013 D & L ENERGY INC Brine 0 365
2014 D & L ENERGY INC Brine 0 365
2015 BOBCAT WELL & PIPELINE LLC Brine 345
2016 BOBCAT WELL & PIPELINE LLC Brine 0 347
2017 BOBCAT WELL & PIPELINE LLC Brine 1 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1670884349 2013-9-16 0:00: UP No Violations 1.00
1209763456 2004-03-08 Preliminary Restoration No Violations Restoration approved .
1670884349 2013-09-16 UrbanProduction Wells No Violations My inspection found the well in production. The well was equipped with a plunger lift unit and a domestic gas line. A wooden fence surrounded the well. The fence was missing wooden slats and the gate was off the hinge. The tank battery contained a 100 barrel production tank, a 50 barrel brine tank, and a separator. There were plugs on the load lines. The dike was slightly weathered; however, it meets containment requirements. The wooden fence surrounding the tank battery was missing a panel. There were no locks on the fences. The proper identification sign was posted. The lease road was in good condition. The well tender was on location. I told the well tender to install locks and repair the wooden fences at the tank battery and well.

For data sources see[9]

References