X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-23727

Well Details

Well ID: 34-155-23727
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Bazetta Township
Operator Name: SOUND ENERGY CO INC
Well Pad ID:
Farm/Lease Name: SHOEMAKER-NEWBROUGH # 1-D
License Status: Producing
License Date: 2000-10-02
Spud Date: 2001-03-22
Spud Drilling Contractor: ADVENT DRLG
Final Drill Date: 2001-03-30
Well Total Depth: 4877.00 ft
Configuration: Directional
Latitude: 41.300000
Longitude: -80.770000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2000-10-02 2911 WEINSZ OIL & GAS INC Proposed Formation CLINTON Issued Date 10/2/00 Expired Date 10/2/01 6:00:00 AM
Original Spud 2001-03-22 RBDMS Rec
Completed 2001-03-30 RBDMS Rec
Reached Total Depth 2001-03-30 RBDMS Rec
Completion Report Received 2001-07-02 RBDMS Rec
Correction to Well 2001-07-20 CHANGE IN TARGET INFORMATION: 263'NL & 944'WL OF LOT 65; X= 2,476,388; Y= 599,962; CHANGE IN DRILL UNIT SIZE TO 40 ACRES; (SOURCE OF LOCATION: AS DRILLED PLAT)
Construction Permit Expires 2001-10-02 RBDMS Rec
Change of Owner 2004-05-06 Operator changed from 2911, WEINSZ OIL & GAS INC to 7626, M & M ROYALTY LTD
Change of Owner 2015-05-12 Operator changed from 7626, M & M ROYALTY LTD to 4327, SOUND ENERGY CO INC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2001-09-10 4614 4744 0
4614 4744 0
4614 4744 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2100 Bbl 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 WEINSZ OIL & GAS INC 13730.00 131.00 220
2002 WEINSZ OIL & GAS INC 18405.00 199.00 365
2003 WEINSZ OIL & GAS INC 1712.00 78.00 365
2004 M & M ROYALTY LTD 1382.00 0.00 365
2005 M & M ROYALTY LTD 10426.00 136.00 365
2006 M & M ROYALTY LTD 8859.00 0.00 365
2007 M & M ROYALTY LTD 8557.00 59.00 365
2008 M & M ROYALTY LTD 7767.00 65.00 365
2009 M & M ROYALTY LTD 7119.00 0.00 365
2010 M & M ROYALTY LTD 6706.00 69.00 365
2011 M & M ROYALTY LTD 5722.00 0.00 365
2012 M & M ROYALTY LTD 3840.00 0.00 366
2013 M & M ROYALTY LTD 3919.00 0.00 365
2014 M & M ROYALTY LTD 4777.00 58.00 365
2015 SOUND ENERGY CO INC 2013.00 0.00 305
2016 SOUND ENERGY CO INC 3216.00 0.00 365
2017 SOUND ENERGY CO INC 3126.00 0.00 365
2018 SOUND ENERGY CO INC 3138.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 WEINSZ OIL & GAS INC Brine 155 220
2002 WEINSZ OIL & GAS INC Brine 58 365
2003 WEINSZ OIL & GAS INC Brine 0 365
2004 M & M ROYALTY LTD Brine 0 365
2005 M & M ROYALTY LTD Brine 0 365
2006 M & M ROYALTY LTD Brine 0 365
2007 M & M ROYALTY LTD Brine 0 365
2008 M & M ROYALTY LTD Brine 0 365
2009 M & M ROYALTY LTD Brine 26 365
2010 M & M ROYALTY LTD Brine 0 365
2011 M & M ROYALTY LTD Brine 0 365
2012 M & M ROYALTY LTD Brine 0 366
2013 M & M ROYALTY LTD Brine 0 365
2014 M & M ROYALTY LTD Brine 5 365
2015 SOUND ENERGY CO INC Brine 10 305
2016 SOUND ENERGY CO INC Brine 0 365
2017 SOUND ENERGY CO INC Brine 0 365
2018 SOUND ENERGY CO INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1543319733 2014-7-11 0:00: UP No Violations 0.30
-1766715048 2008-8-21 0:00: PW No Violations
-1921238470 2003-12-23 0:00 PL No Violations
-867872329 2008-2-14 0:00: PW No Violations
00001250i6 2001-03-26 pl No Violations 10:00 A.M./ Arrived on site to find Advent Drlg. Co. drilling at 1926 ft. . Drilling in shale and was making kick toward T.D. of well. Co. run deviation tool at 1932 ft. . Drilling at 1964 ft. when I Left site.11:00 A.M. . 11:30 A.M. / I rearived to find rig drlg. At 2000 ft. . Co. run deviation tool at 2025 ft. . Run deviation tool at 2119 ft. . Run deviation tool at 2212 ft. . Left site.2:30 P.M. . 9 PM/ Arrived on site to find rig drilling at 2589 ft. .Run devition tool at 2678 ft. . Run deviation tool at 2710 ft. . Start tripping pipe at 2720 ft. to retrieve bottom hole motor. LEFT SITE.1:00 A.M. .
00001250i8 2001-03-27 Drill / Deepen / Reopen No Violations 10:30 A.M. Arrived on site to find rig drilling at 2800 ft. .Well site showed no visible sign of violations. Rig was drilling at 2898 ft. when I left site. 2:30 P.M./ Re-arrived on site to find rig drilling at 2942 ft. . Rig drilling at 2985 ft. when I left site. 3:30 P.M. .
0001250i10 2001-03-28 Drill / Deepen / Reopen No Violations 12:30 A.M./ Rig was tripping pipe out of well when I arrived on site. Rig out of hole at 3:30 A.M. . Sean Speedy/Directional Drilling Specialist and rig crew changed reamer bushings on bottom collar. Rig had 3 stands in well when I left site@ 4:30 A.M. . 2:00 P.M./ Rig was running deviation tool @ 3786 when I arrived on site. I walked around drilling pit/rig and wellsite areas and found no visible violations of 1509 O.R.C. . Run deviation tool @ 4004 . 5:30 P.M./ Left site.
0001250i11 2001-03-29 Drill / Deepen / Reopen No Violations 12:00 A.M./ Rig was tripping pipe from well. They were at 4192 ft. . They was pulling the collars when I arrived. There was no visible sign of violations of 1509 O.R.C. . Rig was apprxomately half-way in well with pipe when I left site @ 4:00 A.M. .
0101677797 2002-10-23 Preliminary Restoration No Violations Meets requirements.
0867872329 2008-02-14 Production Wells No Violations no violations .
101677797 2002-10-23 0:00 PL No Violations 0.50
1250i10 2001-3-28 0:00: DD No Violations
1250i11 2001-3-29 0:00: DD No Violations
1250i6 2001-3-26 0:00: pl No Violations
1250i8 2001-3-27 0:00: DD No Violations
1543319733 2014-07-11 UrbanProduction Wells No Violations I was on location for a status check inspection. I found during my inspection the well in production with a plunger lift unit. The tank battery consisted of two, 100 barrel production tanks, two, 50 barrel brine tanks and two separators. There was a dike surrounding the tank battery. Identification signs were posted at the well and tank battery. There was a plug on the load line. Locked, chain link fences with barb wire surrounded the tank battery and well. The tank battery location was shared with permit number 2-3726. The lease road was well maintained with crushed limestone and gate. The well was placed into production prior to House Bill 278.
1766715048 2008-08-21 Production Wells No Violations no violations .
1921238470 2003-12-23 Preliminary Restoration No Violations Restoration approved .

For data sources see[9]

References