34-155-23730

Well Details

Well ID: 34-155-23730
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Bazetta Township
Operator Name: SOUND ENERGY CO INC
Well Pad ID:
Farm/Lease Name: WESTBAY # 2-D
License Status: Producing
License Date: 2000-10-02
Spud Date: 2001-05-15
Spud Drilling Contractor: ADVENT DRLG
Final Drill Date: 2001-05-22
Well Total Depth: 5115.00 ft
Configuration: Directional
Latitude: 41.300000
Longitude: -80.760000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2000-10-02 2911 WEINSZ OIL & GAS INC Proposed Formation CLINTON Issued Date 10/2/00 Expired Date 10/2/01 6:00:00 AM
Original Spud 2001-05-15 RBDMS Rec
Completed 2001-05-22 RBDMS Rec
Reached Total Depth 2001-05-22 RBDMS Rec
Completion Report Received 2001-07-02 RBDMS Rec
Correction to Well 2001-07-20 CHANGE IN TARGET INFORMATION: 15'NL & 108'EL OF LOT 56; X= 2,477,811; Y= 602,852 (SOURCE OF LOCATION: AS DRILLED PLAT)
Construction Permit Expires 2001-10-02 RBDMS Rec
Change of Owner 2004-05-06 Operator changed from 2911, WEINSZ OIL & GAS INC to 7626, M & M ROYALTY LTD
Change of Owner 2015-05-12 Operator changed from 7626, M & M ROYALTY LTD to 4327, SOUND ENERGY CO INC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2001-09-10 4892 5020 0
4892 5020 0
4892 5020 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2100 Bbl 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 WEINSZ OIL & GAS INC 30903.00 612.00 199
2002 WEINSZ OIL & GAS INC 83687.00 456.00 365
2003 WEINSZ OIL & GAS INC 5365.00 0.00 365
2004 M & M ROYALTY LTD 4204.00 0.00 365
2005 M & M ROYALTY LTD 30043.00 170.00 365
2006 M & M ROYALTY LTD 23877.00 130.00 365
2007 M & M ROYALTY LTD 23602.00 80.00 365
2008 M & M ROYALTY LTD 22366.00 89.00 365
2009 M & M ROYALTY LTD 20399.00 98.00 365
2010 M & M ROYALTY LTD 20060.00 73.00 365
2011 M & M ROYALTY LTD 18378.00 41.00 365
2012 M & M ROYALTY LTD 12367.00 0.00 366
2013 M & M ROYALTY LTD 9330.00 38.00 365
2014 M & M ROYALTY LTD 8550.00 0.00 365
2015 SOUND ENERGY CO INC 5685.00 38.00 305
2016 SOUND ENERGY CO INC 9058.00 35.00 365
2017 SOUND ENERGY CO INC 7753.00 67.00 365
2018 SOUND ENERGY CO INC 6884.00 33.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 WEINSZ OIL & GAS INC Brine 265 199
2002 WEINSZ OIL & GAS INC Brine 85 365
2003 WEINSZ OIL & GAS INC Brine 0 365
2004 M & M ROYALTY LTD Brine 0 365
2005 M & M ROYALTY LTD Brine 0 365
2006 M & M ROYALTY LTD Brine 0 365
2007 M & M ROYALTY LTD Brine 18 365
2008 M & M ROYALTY LTD Brine 0 365
2009 M & M ROYALTY LTD Brine 0 365
2010 M & M ROYALTY LTD Brine 0 365
2011 M & M ROYALTY LTD Brine 0 365
2012 M & M ROYALTY LTD Brine 0 366
2013 M & M ROYALTY LTD Brine 0 365
2014 M & M ROYALTY LTD Brine 20 365
2015 SOUND ENERGY CO INC Brine 0 305
2016 SOUND ENERGY CO INC Brine 0 365
2017 SOUND ENERGY CO INC Brine 0 365
2018 SOUND ENERGY CO INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-108750623 2013-2-12 0:00: UP No Violations 0.50
-1447458115 2008-2-14 0:00: PW No Violations
-159657424 2014-7-11 0:00: UP No Violations 0.30
0101377794 2002-10-23 Preliminary Restoration No Violations Meets requirements.
0108750623 2013-02-12 UrbanProduction Wells No Violations My inspection found the well equipped with a plunger lift unit. It was surrounded by a locked chain link fence with the proper identification sign. The tank battery contained one, 100 barrel production tank, one, 50 barrel brine tank, and a separator. It was surrounded by a locked chain link fence and the proper dike. The proper identification sign was posted. The separator had a 7 day production chart. This well shares a tank battery location with permit number 3731 and an Everflow Eastern Inc. well: 2-3141. The lease road was in great condition with crushed limestone. The production records were up to date on our database. This well was placed into production prior to House Bill 278.
0159657424 2014-07-11 UrbanProduction Wells No Violations I was on location for a status check inspection. I found during my inspection the well in production with a plunger lift unit. The tank battery consisted of a 100 barrel production tank, a 50 barrel brine tank and a separator. There was a dike surrounding the tank battery. Identification signs were posted at the well and tank battery. There was a plug on the load line. Locked, chain link fences with barb wire surrounded the tank battery and well. The tank battery was shared with permit number 2-3731. An Everflow tank battery was located in the same fenced area; however, both tank batteries had separate dikes. The lease road was well maintained with crushed limestone. The well was placed into production prior to House Bill 278.
0203193918 2002-12-17 pl No Violations Check well per waterwell investigation . Case # 02-008 . Inspection showed no visible violations .
0807130152 2016-11-19 UrbanProduction Wells No Violations

-3731 and 2-3141. The RBDMS database shows Sound Energy took ownership on 5/12/2015.

The equipment on the site consists of the following:



101377794 2002-10-23 0:00 PL No Violations 0.50
1278339116 2003-12-23 Preliminary Restoration No Violations Restoration approved .
1284106650 2008-08-21 Production Wells No Violations no violations .
1447458115 2008-02-14 Production Wells No Violations no violations .
203193918 2002-12-17 0:00 pl No Violations
807130152 2016-11-19 0:00 UP No Violations 0.30

For data sources see[9]