Well Details

Well ID: 34-155-23767
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: AMERICAN ENERGY ASSOCIATES INC
Well Pad ID:
Farm/Lease Name: ST DEMETRIOS
License Status: Producing
License Date: 2004-03-18
Spud Date: 2004-04-20
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2004-04-25
Well Total Depth: 4725.00 ft
Configuration: Vertical
Latitude: 41.240000
Longitude: -80.780000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2004-03-18 Proposed Formations:CLINTON, Issued Date:3/18/2004, Expired Date:3/18/2005 6:00:00 AM, Drilling unit acres:52.48, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2004-04-20 RBDMS Rec
Completed 2004-04-25 RBDMS Rec
Reached Total Depth 2004-04-25 RBDMS Rec
Completion Report Received 2004-07-19 RBDMS Rec
Construction Permit Expires 2005-03-18 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2004-09-28 4497 4638 19
4497 4638 19
4497 4638 19

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 80000 Gal 60000 500 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2004 AMERICAN ENERGY ASSOCIATES INC 3717.00 561.00 137
2005 AMERICAN ENERGY ASSOCIATES INC 43118.00 982.00 365
2006 AMERICAN ENERGY ASSOCIATES INC 29081.00 259.00 365
2007 AMERICAN ENERGY ASSOCIATES INC 23288.00 197.00 365
2008 AMERICAN ENERGY ASSOCIATES INC 132.00 0.00 365
2009 AMERICAN ENERGY ASSOCIATES INC 16127.00 68.00 365
2010 AMERICAN ENERGY ASSOCIATES INC 10238.00 0.00 365
2011 AMERICAN ENERGY ASSOCIATES INC 16279.00 76.00 365
2012 AMERICAN ENERGY ASSOCIATES INC 13412.00 81.00 366
2013 AMERICAN ENERGY ASSOCIATES INC 13713.00 67.00 365
2014 AMERICAN ENERGY ASSOCIATES INC 12057.00 64.00 365
2015 AMERICAN ENERGY ASSOCIATES INC 11017.00 0.00 365
2016 AMERICAN ENERGY ASSOCIATES INC 10312.00 74.00 365
2017 AMERICAN ENERGY ASSOCIATES INC 9729.00 0.00 365
2018 AMERICAN ENERGY ASSOCIATES INC 9124.00 74.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2004 AMERICAN ENERGY ASSOCIATES INC Brine 57 137
2005 AMERICAN ENERGY ASSOCIATES INC Brine 50 365
2006 AMERICAN ENERGY ASSOCIATES INC Brine 0 365
2007 AMERICAN ENERGY ASSOCIATES INC Brine 45 365
2008 AMERICAN ENERGY ASSOCIATES INC Brine 18417 365
2009 AMERICAN ENERGY ASSOCIATES INC Brine 0 365
2010 AMERICAN ENERGY ASSOCIATES INC Brine 0 365
2011 AMERICAN ENERGY ASSOCIATES INC Brine 0 365
2012 AMERICAN ENERGY ASSOCIATES INC Brine 0 366
2013 AMERICAN ENERGY ASSOCIATES INC Brine 0 365
2014 AMERICAN ENERGY ASSOCIATES INC Brine 0 365
2015 AMERICAN ENERGY ASSOCIATES INC Brine 0 365
2016 AMERICAN ENERGY ASSOCIATES INC Brine 0 365
2017 AMERICAN ENERGY ASSOCIATES INC Brine 0 365
2018 AMERICAN ENERGY ASSOCIATES INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1289188311 2004-4-20 0:00: DD No Violations
-1722735133 2012-10-31 0:00 UP No Violations 0.50
0375802645 2016-11-27 UrbanProduction Wells No Violations


The equipment on the site consists of the following:



0395033898 2015-11-03 UrbanProduction Wells No Violations I was on location for a status check. During my inspection, I found the well in production. The well is equipped with a plunger lift assembly. The tank battery consists of a 100 barrel production tank, a 50 barrel brine tank, and a mechanical separator. Locked, chain link fences surround the tank battery and well. There are dikes around the well and tank battery. An identification sign is posted. Domestic gas lines comes off of the sales line at the separator and off of the wells 4.5 casing. The lease road is in stable condition.
0986741810 2017-12-29 UrbanProduction Wells No Violations I was on location to assess Chiefs Order 2017-274. I found the well in production with an open gate valve on the tubing and open ball valve on the flow line. There is a chart box and 7 day chart dated 12/28/2017 on the sales line after the separator. There are two (2) domestic gas supplies with one (1) at the separator and the other coming off of the wellhead. There are locked chain link fences at the tank battery and well. There is an identification sign posted. I spoke with Bob Barnett from American Energy Associates. Mr. Barnett stated the company does have insurance and will call Columbus ODNR on 1/2/2018 to correct the issue.

American Energy needs to: Immediately shut-in the production well Submit updated Liability Insurance

1289188311 2004-04-20 Drill / Deepen / Reopen No Violations Wellsite in construction , Cappstar moving onsite .
1354548371 2012-12-03 UrbanProduction Wells No Violations My follow-up inspection found a lock installed on the fence at the well and an identification sign.
1395922596 2014-03-27 UrbanPreliminary Restoration No Violations My inspection found the well equipped with a plunger lift unit. The tank battery consisted of a 100 barrel production tank, a 50 barrel brine tank, and a vertical separator. The dike met containment requirements. An identification sign was properly posted. Locked, chain link fences with barb wire surrounded the production equipment and the well. The site was graded and vegetated. The pits were closed. The lease road was part of the church parking lot. Preliminary restoration passed.
1576685405 2019-12-18 0:00 UP No Violations
1722735133 2012-10-31 UrbanProduction Wells No Violations I conducted an urban production well inspection status check. My inspection found the well equipped with a plunger lift unit surrounded by a chain link fence with no identification sign or lock. The tank battery surrounded by a chain link fence, a dike, and contained one, 100 barrel oil storage tank, one, 50 barrel brine storage tank, a separator, and the proper identification sign. I called American Energy Inc. at 440-862-4041 and asked for the proper identification and lock to be place on the wellhead fence. I will re-inspect by 11/7/2012.
375802645 2016-11-27 0:00 UP No Violations 0.50
395033898 2015-11-3 0:00: UP No Violations 0.50
986741810 2017-12-29 0:00 UP No Violations 0.70

For data sources see[9]