34-155-23858

Well Details

Well ID: 34-155-23858
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hubbard Township
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: WALLEY
License Status: Producing
License Date: 2007-04-27
Spud Date: 2007-05-09
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2007-05-15
Well Total Depth: 5307.00 ft
Configuration: Vertical
Latitude: 41.150000
Longitude: -80.610000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-04-27 Proposed Formations:CLINTON, Issued Date:4/27/2007, Expired Date:4/26/2008 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-05-15
Reached Total Depth 2007-05-15
Completion Report Received 2007-10-01
Construction Permit Expires 2008-04-26
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-01-02 5000 5058 149
5000 5058 149
5000 5058 149

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2500 Bbl 75000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 PAC DRILLING LLC 20621.00 501.00 326
2010 PAC DRILLING LLC 16960.00 472.00 339
2011 PAC DRILLING LLC 9304.00 332.00 343
2012 PAC DRILLING LLC 6926.00 319.00 346
2013 PAC DRILLING LLC 5119.00 249.00 365
2014 PAC DRILLING LLC 4019.00 276.00 360
2015 PAC DRILLING LLC 3940.00 165.00 360
2016 PAC DRILLING LLC 3548.00 194.00 357
2017 PAC DRILLING LLC 3481.00 234.00 357
2018 PAC DRILLING LLC 3025.00 179.00 357

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 PAC DRILLING LLC Brine 0 326
2010 PAC DRILLING LLC Brine 0 339
2011 PAC DRILLING LLC Brine 0 343
2012 PAC DRILLING LLC Brine 38 346
2013 PAC DRILLING LLC Brine 68 365
2014 PAC DRILLING LLC Brine 0 360
2015 PAC DRILLING LLC Brine 21 360
2016 PAC DRILLING LLC Brine 25 357
2017 PAC DRILLING LLC Brine 28 357
2018 PAC DRILLING LLC Brine 11 357

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1092165209 2011-9-16 0:00: PL No Violations
-1430577666 2020-3-31 0:00: UP No Violations
-1828287607 2016-10-24 0:00 UP No Violations 0.70
-2045872803 2017-2-15 0:00: UP No Violations 0.70
-211697185 2014-6-26 0:00: UP No Violations 0.50
-413583261 2018-5-11 0:00: UP No Violations
0211697185 2014-06-26 UrbanProduction Wells No Violations I was on location for a status check inspection. I found during my inspection the plunger lift unit in production. The tank battery consisted of a 210 barrel production tank, a 50 barrel poly tank and a separator. A dike surrounded the production equipment. Identification signs were properly posted at the well and production tank. The load line had a bull plug. Locked, chain link fences surrounded the production equipment and well. The lease road was in stable condition.
0413583261 2018-05-11 UrbanProduction Wells Violations Noted At the time of this inspection, the well was equipped with a plunger lift assembly. The annulus and flow line valves were open. There was an identification posted on the chain link fence that surrounds the well, but the fence still needs a lock. The diked tank battery has two storage tanks and a separator. The pick-up line has a plug, but still needs a lock or the handles removed. There was a leaking 2 inch ball valve inside of the separator, which has leaked out onto the ground in front of the separator. There is a build-up of salt and rust on the 2 inch ball valve and the fittings below it. The pick-up lines have plugs, but need locks or the handles remvoed. There was a locked chain link fence around the tank battery. The top of the production tank extend more than 3 foot above the fence and needs modified as required by 1501:9-9--9--e). An identification sign was posted on the fencing, but was missing the required information per 1501:9-9--e). There was a domestic gas supply coming off of the sales line west of the tank battery. There was no landscaping at the tank battery; however, the tank battery and well is located over 1,000 feet from Route 304 on commercial/industrial property. The access road was stable with no gate at the entrance. The access road is the entrance for several commercial/industrial businesses.
0835981750 2018-07-16 UrbanProduction Wells No Violations I conducted a compliance notice follow-up for compliance notice 413583261. At the time of this inspection, the well still needs a lock on the fence man door. The handles have been removed from the pick-up lines. The leaking 2 inch ball valve inside of the separator, has been repaired. The built up salt crystals and absorbant pads inside the separator have not been cleaned up and removed. The impacted soil outside of the separator from the leaking valve still needs removed. There was a locked chain link fence around the tank battery. The top of the production tank extend more than 3 foot above the fence and needs modified as required by 1501:9-9--9--e). An identification sign was posted on the fencing, but was missing the required information per 1501:9-9--e). There has been no landscaping installed around the tank battery.
1092165209 2011-09-16 Preliminary Restoration No Violations Preliminary Restoration was completed.
1828287607 2016-10-24 UrbanProduction Wells No Violations


PAC Drilling will: Install the proper urban safety equipment.


-pressure relief valve

Install locks on the load lines or remove the valve handles Install locks on the fences at the well and tank battery.

The equipment on the site consists of the following:



On 12/13/2016, Northeast Regional Supervisor Tom Hill and I met with Justin Caldwell, co-owner of PAC Drilling, and Rusty Hornhill, well tender for PAC Drilling concerning the missing required urban safety equipment on 31 PAC Drilling wells in Hubbard and Liberty Townships. Mr. Caldwell has been given a document listing the wells with the missing the urban safety equipment. PAC Drilling is to submit a schedule for equipment installation for review and approval by the Division of Oil & Gas.

1871265892 2007-05-08 Drill / Deepen / Reopen No Violations Kilbarger setting 84 of 11 3/4 conductor casing .
1891973001 2019-02-04 UrbanProduction Wells No Violations I conducted a compliance notice follow-up for compliance notice 413583261, regarding multiple compliance issues related to urban rule requirements. At the time of this inspection, a lock has been added to the well fence man door. The handles have been removed from the pick-up lines. The leaking 2 inch ball valve inside of the separator, has been repaired. The impacted soil outside of the separator from the leaking valve has been remedied. There was a locked chain link fence around the tank battery. The top of the production tank extend more than 3 foot above the fence and needs modified as required by 1501:9-9-05E(4)(f). The production tank was missing the required urban safety equipment, and needs installed as required by 1501:9-9-05E(4)(b-e). Only a charcoal filter has been installed on the 210 BBL tank. A pressure relief valve and spark arrestor still need to be installed on the 210 BBL production tank. The identification was posted on the fencing and amended required information has been added per 1501:9-9-05E(1)(a-e). There has been no landscaping installed around the tank battery.

PAC needs to: 1) Install urban safety equipment on the production tank as required by 1501:9-9-05E(4)(b-e): Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor 2) Install the landscaping at the tank battery location as required per 1501:9-9-05(E)(6)(a-c).

2045872803 2017-02-15 UrbanProduction Wells No Violations
9-05(E)(1)(a-

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). -up line at the site tube.

714524600 2019-11-18 0:00 UP No Violations
835981750 2018-7-16 0:00: UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0413583261 US-OH-124390 2018-05-25 9-05E1 ID (a-i)
0413583261 US-OH-124391 2018-05-25 9-05E2 FENCING (a-d)
0413583261 US-OH-124392 2018-05-25 9-05E3 LOCKS
0413583261 US-OH-124393 2018-05-25 9-05E4 TANKS (a-i)
0413583261 US-OH-124394 2018-05-25 9-9-05(A)9 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[9]