Well Details

Well ID: 34-155-23886
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hubbard Township
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: CATONE
License Status: Producing
License Date: 2007-11-27
Spud Date: 2007-12-07
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2007-12-12
Well Total Depth: 5312.00 ft
Configuration: Vertical
Latitude: 41.150000
Longitude: -80.600000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-11-27 Proposed Formations:CLINTON, Issued Date:11/27/2007, Expired Date:11/26/2008 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2007-12-12
Completion Report Received 2008-03-04
Construction Permit Expires 2008-11-26
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-07-01 5024 5090 54
5024 5090 54
5024 5090 54

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 44250 FRAC WATER VOLUME NOT REPORTED

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 PAC DRILLING LLC 28494.00 1054.00 331
2009 PAC DRILLING LLC 23890.00 737.00 354
2010 PAC DRILLING LLC 18078.00 362.00 341
2011 PAC DRILLING LLC 11010.00 456.00 350
2012 PAC DRILLING LLC 6966.00 219.00 361
2013 PAC DRILLING LLC 5295.00 203.00 365
2014 PAC DRILLING LLC 4162.00 185.00 360
2015 PAC DRILLING LLC 4175.00 186.00 363
2016 PAC DRILLING LLC 3032.00 160.00 356
2017 PAC DRILLING LLC 2873.00 150.00 357
2018 PAC DRILLING LLC 3182.00 159.00 357

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 PAC DRILLING LLC Brine 50 331
2009 PAC DRILLING LLC Brine 46 354
2010 PAC DRILLING LLC Brine 40 341
2011 PAC DRILLING LLC Brine 63 350
2012 PAC DRILLING LLC Brine 28 361
2013 PAC DRILLING LLC Brine 0 365
2014 PAC DRILLING LLC Brine 0 360
2015 PAC DRILLING LLC Brine 40 363
2016 PAC DRILLING LLC Brine 0 356
2017 PAC DRILLING LLC Brine 52 357
2018 PAC DRILLING LLC Brine 0 357

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1116325590 2015-9-16 0:00: UP No Violations 0.70
-1132792911 2017-12-18 0:00 UP No Violations 0.40
-1340309802 2011-5-10 0:00: PL No Violations
-137373418 2019-2-4 0:00:0 UP No Violations 0.50
-1566669487 2017-10-16 0:00 UP No Violations 0.40
-2053733073 2019-11-18 0:00 UP No Violations
-507279978 2017-3-17 0:00: UP No Violations 0.90
-873638231 2018-7-16 0:00: UP No Violations
0137373418 2019-02-04 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1566669487, regarding multiple compliance issues related to urban rule requirements. At the time of this inspection, there was still no lock on the well man door fence and identification still needs added at the well location. The tank valve on the 50 BBL poly tank has been repaired. An identification sign was posted at the tank battery, and has been amended with the required information per 1501:9-9-05E(1)(a-e). The locked chain link fence surrounding the tank battery; has not been replaced with the required 8 foot fence per: 1501:9-9-05E(2). There was no landscaping at the tank battery or well. Place landscaping at the tank battery as required by 1501:9-9-05E(6).

PAC needs to: 1) The existing fence needs replaced with the required 8 foot fence at the tank battery per: 1501:9-9-05E(2). 2) Complete the required landscaping at the tank battery per 1501:9-9-05(E)(6)(a-c). 3) Install a lock and identification at the well location.

0507279978 2017-03-17 UrbanProduction Wells No Violations

-up lines have plugs, but no locks. The 210 bbl. storage tank has the required urban safety equipment. An identification sign is posted at the tank battery. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a--

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install locks on the pick-up lines or remove the valve handles as required by 1501:9-9-05(E)(3). 3) Install a lock on the fencing at the well as required by 1501:9-9-05(E)(3). -9-05(E)(2) & 1501:9-9-05(E)(4)(f). 5) Place landscaping at the tank battery as required by 1501:9-9-05(E)(6).

The equipment on the pad consists of the

0590276033 2015-10-14 UrbanProduction Wells No Violations I was on location in reference to Compliance Notice No. -1116325590. During my inspection, urban safety equipment has been installed on the production tank. All compliance issues have been corrected.
0873638231 2018-07-16 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1566669487. At the time of this inspection, there was still no lock on the well man door fence. The tank valve on the 50 BBL poly tank was no longer dripping brine because the 50 BBL poly tank had been emptied. It had not been repaired or disconnected from the other production equipment. An identification sign was posted at the tank battery, but was still missing the required information per 1501:9-9--e). The locked chain link fence surrounding the tank battery; has not been replaced with the required 8 foot fence per: 1501:9-9--9--9-
1116325590 2015-09-16 UrbanProduction Wells Violations Noted I was on location for an urban status check. During my inspection, I found the well in production. The tank battery consists of a 210 barrel production tank, a 50 barrel, poly brine tank, and a mechanical separator. A dike surrounds the tank battery. Identification signs are posted at the well and tank battery. I observed no plug or lock on the load line. There is no urban safety equipment on the production tank. There are locked, chain link fences around the tank battery and well. The lease road is in stable condition. A compliance notice has been issued to:


Well shall be shut in immediately until all needed equipment is installed. Failure to do so will result in civil penalties. A follow-up inspection will be conducted by 10/09/2015.

1132792911 2017-12-18 UrbanProduction Wells No Violations I found the proper urban safety equipment installed on the production tank. The handles have been removed from the pick-up lines. PAC still needs to:

Install a lock on the fencing at the well.

Place landscaping on the north side at the tank battery.

1340309802 2011-05-10 Preliminary Restoration No Violations Preliminary restoration meets all requirements.
1346864099 2012-09-05 UrbanProduction Wells No Violations I completed an urban production well inspection. My inspection found the well equipped with a plunger lift unit (rabbit) that was in good condition. The tank battery was surrounded by a chain link fence and contained one 210 barrel oil barrel storage tank, one 50 barrel brine storage tank, a separator, and the proper identification. I noticed no visible spills or leaks. The lease road was in good condition. There are no violations at this time.
1526482027 2018-05-11 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1566669487. At the time of this inspection, the well was equipped with a plunger lift assembly. The annulus and 2 inch flow line valves were open. An active domestic gas supply comes off of the wellhead. Identification was posted at the well. There was a chain link fence with no lock around the well. Install a lock at the well fence as required by 1501:9-9--up lines have plugs and the handles removed. The 210 BBL tank has the required urban safety equipment. An identification sign is posted at the tank battery. The identification sign is missing the required information per 1501:9-9--e). There is a locked chain link fence surrounding the tank battery; however, the fencing is 6 foot in height and needs to be 8 feet in height per requirement 1501:9-9--9--9-
1562082389 2019-7-2 0:00:0 UP No Violations
1566669487 2017-10-16 UrbanProduction Wells Violations Noted 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with:

Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install a lock on the fencing at the well as required by 1501:9-9-05(E)(3). -9-05(E)(2) & 1501:9-9-05(E)(4)(f). 4) Place landscaping on the north side at the tank battery as required by 1501:9-9-05(E)(6).

590276033 2015-10-14 0:00 UP No Violations 0.50
693533095 2020-3-31 0:00: UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1116325590 US-OH-102922 2015-10-15 LOCKS
1116325590 US-OH-102923 2015-10-15 TANKS (a-i)
1566669487 US-OH-115302 2017-12-26 ID (a-i)
1566669487 US-OH-115303 2017-12-26 FENCING (a-d)
1566669487 US-OH-115304 2017-12-26 LOCKS
1566669487 US-OH-115305 2017-12-26 LANDSCAPING (a-c)

For data sources see[9]