If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-23887 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.16,"lon":-80.61,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Hubbard Township | |
Operator Name: PAC DRILLING LLC | |
Well Pad ID: | |
Farm/Lease Name: FERRARA | |
License Status: Producing | |
License Date: 2007-11-28 | |
Spud Date: 2007-12-15 | |
Spud Drilling Contractor: KILBARGER DRLG | |
Final Drill Date: 2007-12-22 | |
Well Total Depth: 5362.00 ft | |
Configuration: Vertical | |
Latitude: 41.160000 | |
Longitude: -80.610000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2007-11-28 | Proposed Formations:CLINTON, Issued Date:11/28/2007, Expired Date:11/27/2008 6:00:00 AM, Drilling unit acres:221.51, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2007-12-22 | WELL PRODUCES FROM CLINTON & MEDINA SANDS |
Completion Report Received | 2008-03-04 | WELL PRODUCES FROM CLINTON & MEDINA SANDS |
Construction Permit Expires | 2008-11-27 | WELL PRODUCES FROM CLINTON & MEDINA SANDS |
Record Last Modified | 2015-09-24 | WELL PRODUCES FROM CLINTON & MEDINA SANDS |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-07-02 | 5038 | 5130 | 47 |
2008-07-02 | 5199 | 5210 | 6 |
5038 | 5130 | 47 | |
5199 | 5210 | 6 | |
5038 | 5130 | 47 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 0 | 50000 | FRAC WATER VOLUME NOT REPORTED… SINGLE FRAC SAND VOLUME AND SINGLE SET OF RESERVOIR PRESSURES REPORTED, EVEN THOUGH WELL WAS COMPLETED IN CLINTON AND MEDINA SANDS… GM | ||
H2O | 0 | 0 | 0 | FRAC WATER VOLUME NOT REPORTED… SINGLE FRAC SAND VOLUME AND SINGLE SET OF RESERVOIR PRESSURES REPORTED, EVEN THOUGH WELL WAS COMPLETED IN CLINTON AND MEDINA SANDS… GM |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | PAC DRILLING LLC | 25840.00 | 1222.00 | 333 |
2009 | PAC DRILLING LLC | 20481.00 | 747.00 | 333 |
2010 | PAC DRILLING LLC | 17452.00 | 452.00 | 328 |
2011 | PAC DRILLING LLC | 8400.00 | 345.00 | 337 |
2012 | PAC DRILLING LLC | 6293.00 | 376.00 | 362 |
2013 | PAC DRILLING LLC | 3786.00 | 333.00 | 365 |
2014 | PAC DRILLING LLC | 3358.00 | 228.00 | 360 |
2015 | PAC DRILLING LLC | 3579.00 | 240.00 | 360 |
2016 | PAC DRILLING LLC | 2201.00 | 207.00 | 359 |
2017 | PAC DRILLING LLC | 1887.00 | 193.00 | 359 |
2018 | PAC DRILLING LLC | 2264.00 | 132.00 | 359 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | PAC DRILLING LLC | Brine | 67 | 333 |
2009 | PAC DRILLING LLC | Brine | 60 | 333 |
2010 | PAC DRILLING LLC | Brine | 52 | 328 |
2011 | PAC DRILLING LLC | Brine | 0 | 337 |
2012 | PAC DRILLING LLC | Brine | 0 | 362 |
2013 | PAC DRILLING LLC | Brine | 20 | 365 |
2014 | PAC DRILLING LLC | Brine | 0 | 360 |
2015 | PAC DRILLING LLC | Brine | 40 | 360 |
2016 | PAC DRILLING LLC | Brine | 21 | 359 |
2017 | PAC DRILLING LLC | Brine | 13 | 359 |
2018 | PAC DRILLING LLC | Brine | 15 | 359 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-357534316 | 2010-3-31 0:00: | PW | No Violations | |
0236933599 | 2007-12-18 | Drill / Deepen / Reopen | No Violations | Kilbarger shut-down for repairs . |
0357534316 | 2010-03-31 | Production Wells | No Violations | I received a complaint for mud on road from activity from gas well . Inspection showed mud tracks on road , there was no piles or clumps of mud on road . There isnt any violations per complaint . |
0452196585 | 2017-03-13 | UrbanProduction Wells | No Violations
--up lines have plugs, but no locks. Both of the 210 bbl. storage tanks have the required urban safety equipment. There is an identification sign posted at the tank battery. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a--site inspection. The tank battery is shared with permits #2-3890 and #2-3889. The equipment on the pad consists of the following:
| |
0886008890 | 2009-10-27 | Preliminary Restoration | No Violations | no violations . |
1314859692 | 2019-02-27 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 1861287861, regarding multiple compliance issues related to urban rule requirements. At the time of this inspection, There was no identification posted at the well. There was no fencing around the well and it was not waived during the pre-site inspection. The pick-up lines have plugs, and handles removed at the tank battery location. Identification posted at the tank battery has now been amended with the required information per 1501:9-9-05(E)(1)(a-e). There was a chain link fence around the tank battery but was not eight feet in height and needed a lock on the man door. The 210 BBL storage tank extends more than 3 foot above the top of the fencing. The access road was stable, but no access gate had been installed. The access road gate was not waived during the pre-site inspection.
PAC needs to: 1) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 2) Install the fencing around the well and install identification. 3) Install the required gate with a lock at the access road entrance per 1501:9-9-05(E)(2)(c). 4) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f). |
1351562253 | 2016-02-12 | UrbanProduction Wells | No Violations
| |
1585322041 | 2020-3-27 0:00: | UP | No Violations | |
1861287861 | 2018-05-16 | UrbanProduction Wells | Violations Noted | At the time of this inspection, the well was equipped with a plunger lift assembly. The annulus and flow line valves were open. There was no identification posted at the well. There was no fencing around the well and it was not waived during the pre-site inspection. The well was isolated by thick woodlands from all private residences. The tank battery has three storage tanks and a separator. The pick-up lines have plugs, but no locks. Both of the 210 BBL storage tanks have the required urban safety equipment. There was an identification sign posted at the tank battery, but was missing the required information per 1501:9-9-05(E)(1)(a-e). There was a chain link fence around the tank battery but was not eight feet in height and needed a lock on the man door. The 210 BBL storage tank extends more than 3 foot above the top of the fencing. The access road was stable, but no access gate had been installed. The access road gate was not waived during the pre-site inspection. The tank battery was shared with permits #2-3890 and #2-3889.
PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 3) Install the fencing around the well and the required gate with a lock at the access road entrance per 1501:9-9-05(E)(2)(c). 4) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f). |
236933599 | 2007-12-18 0:00 | DD | No Violations | |
452196585 | 2017-3-13 0:00: | UP | No Violations | 0.70 |
886008890 | 2009-10-27 0:00 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1861287861 | US-OH-118642 | 2018-06-05 | 9-05E1 | ID (a-i) |
1861287861 | US-OH-118643 | 2018-06-05 | 9-05E2 | FENCING (a-d) |
1861287861 | US-OH-118644 | 2018-06-05 | 9-05E3 | LOCKS |
1861287861 | US-OH-118645 | 2018-06-05 | 9-9-02 | General Safety |
For data sources see[9]