X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-23890

Well Details

Well ID: 34-155-23890
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hubbard Township
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: FERRARA
License Status: Producing
License Date: 2007-12-17
Spud Date: 2007-12-30
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2008-01-05
Well Total Depth: 5355.00 ft
Configuration: Vertical
Latitude: 41.170000
Longitude: -80.610000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2007-12-17 Proposed Formations:CLINTON, Issued Date:12/17/2007, Expired Date:12/16/2008 6:00:00 AM, Drilling unit acres:281.52, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-01-05
Completion Report Received 2008-03-04
Construction Permit Expires 2008-12-16
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-07-02 5066 5168 47
5066 5168 47
5066 5168 47

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 50000 FRAC WATER VOLUME NOT REPORTED

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 PAC DRILLING LLC 25840.00 1222.00 333
2009 PAC DRILLING LLC 20481.00 747.00 333
2010 PAC DRILLING LLC 17452.00 452.00 328
2011 PAC DRILLING LLC 8950.00 379.00 337
2012 PAC DRILLING LLC 6293.00 376.00 362
2013 PAC DRILLING LLC 3786.00 333.00 365
2014 PAC DRILLING LLC 3358.00 228.00 360
2015 PAC DRILLING LLC 3579.00 240.00 360
2016 PAC DRILLING LLC 2201.00 207.00 359
2017 PAC DRILLING LLC 1887.00 193.00 359
2018 PAC DRILLING LLC 2264.00 132.00 359

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 PAC DRILLING LLC Brine 67 333
2009 PAC DRILLING LLC Brine 60 333
2010 PAC DRILLING LLC Brine 52 328
2011 PAC DRILLING LLC Brine 0 337
2012 PAC DRILLING LLC Brine 0 362
2013 PAC DRILLING LLC Brine 20 365
2014 PAC DRILLING LLC Brine 0 360
2015 PAC DRILLING LLC Brine 40 360
2016 PAC DRILLING LLC Brine 21 359
2017 PAC DRILLING LLC Brine 13 359
2018 PAC DRILLING LLC Brine 10 359

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1093272835 2008-1-2 0:00:0 DD No Violations
-1260770022 2011-9-13 0:00: PW No Violations
-1598478576 2008-1-23 0:00: PW No Violations
-1758627834 2020-3-27 0:00: UP No Violations
-1777268675 2019-2-27 0:00: UP No Violations
0271721011 2009-10-27 Preliminary Restoration No Violations no violations .
0710512850 2018-05-16 UrbanProduction Wells Violations Noted At the time of this inspection, the well was equipped with a plunger lift assembly. The annulus and flow line valves were open. There identification posted at the well needs reattached to the well fencing. The tank battery has three storage tanks and a separator. The pick-up lines have plugs, but no locks. Both of the 210 BBL storage tanks have the required urban safety equipment. There was an identification sign posted at the tank battery, but was missing the required information per 1501:9-9-05(E)(1)(a-e). There was a chain link fence around the tank battery but was not eight feet in height and needed a lock on the man door. The 210 BBL storage tank extends more than 3 foot above the top of the fencing. The access road was stable, but no access gate had been installed. The access road gate was not waived during the pre-site inspection. The tank battery was shared with permits #2-3890 and #2-3887.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 3) Install the required gate with a lock at the access road entrance per 1501:9-9-05(E)(2)(c). 4) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f).

1093272835 2008-01-02 Drill / Deepen / Reopen No Violations Kilbarger shut-down at this time .
1260770022 2011-09-13 Production Wells No Violations There were no violations found at the time of my inspection.
1412420682 2016-02-12 UrbanProduction Wells No Violations


The equipment on the site consists of the following:


1 Mechanical separator 2 Activated charcoal filters 2 Low-pressure relief valves 2 Lightning arrestors 1 Production well

1539577590 2017-03-13 UrbanProduction Wells No Violations

-up lines have plugs, but no locks. Both of the 210 bbl. storage tanks have the required urban safety equipment. There is an identification sign posted at the tank battery. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a--site inspection. The tank battery is shared with permits #2-3887 and #2-3889.

The equipment on the pad consists of the following:



1598478576 2008-01-23 Production Wells No Violations Case# 08-002 , Inspection showed no violations per distances from well to home or stream .
1777268675 2019-02-27 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 710512850, regarding multiple compliance issues related to urban rule requirements. At the time of this inspection, the identification posted at the well has been reattached to the well fencing. The man door on the well fence needs a lock. The pick-up lines have plugs, and handles removed at the tank battery location. Identification posted at the tank battery has now been amended with the required information per 1501:9-9-05(E)(1)(a-e). There was a chain link fence around the tank battery but was not eight feet in height and needed a lock on the man door. The 210 BBL storage tank extends more than 3 foot above the top of the fencing. The access road was stable, but no access gate had been installed. The access road gate was not waived during the pre-site inspection.

PAC needs to: 1) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 2) Install the required gate with a lock at the access road entrance per 1501:9-9-05(E)(2)(c). 3) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f). 4) Install a lock on the well fence man door.

271721011 2009-10-27 0:00 PL No Violations
710512850 2018-5-16 0:00: UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0710512850 US-OH-128031 2018-06-05 9-05E1 ID (a-i)
0710512850 US-OH-128032 2018-06-05 9-05E2 FENCING (a-d)
0710512850 US-OH-128033 2018-06-05 9-05E3 LOCKS
0710512850 US-OH-128034 2018-06-05 9-9-02 General Safety

For data sources see[9]

References