If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-23894 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.16,"lon":-80.6,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Hubbard Township | |
Operator Name: PAC DRILLING LLC | |
Well Pad ID: | |
Farm/Lease Name: CATONE | |
License Status: Producing | |
License Date: 2008-01-08 | |
Spud Date: 2008-01-16 | |
Spud Drilling Contractor: KILBARGER DRLG | |
Final Drill Date: 2008-01-21 | |
Well Total Depth: 5351.00 ft | |
Configuration: Vertical | |
Latitude: 41.160000 | |
Longitude: -80.600000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2008-01-08 | Proposed Formations:CLINTON, Issued Date:1/8/2008, Expired Date:1/7/2009 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2008-01-21 | |
Completion Report Received | 2008-03-04 | |
Construction Permit Expires | 2009-01-07 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 0 | 50000 | CALLED OPERATOR ON 7/1/08 REQUESTING PERF LOG…
NO FRAC WATER VOLUME REPORTED… GM |
For data sources see[3]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | PAC DRILLING LLC | 22770.00 | 701.00 | 301 |
2009 | PAC DRILLING LLC | 23861.00 | 468.00 | 348 |
2010 | PAC DRILLING LLC | 18099.00 | 361.00 | 341 |
2011 | PAC DRILLING LLC | 10646.00 | 215.00 | 339 |
2012 | PAC DRILLING LLC | 6588.00 | 182.00 | 390 |
2013 | PAC DRILLING LLC | 5295.00 | 166.00 | 360 |
2014 | PAC DRILLING LLC | 6172.00 | 117.00 | 360 |
2015 | PAC DRILLING LLC | 4458.00 | 89.00 | 363 |
2016 | PAC DRILLING LLC | 4068.00 | 87.00 | 357 |
2017 | PAC DRILLING LLC | 3120.00 | 76.00 | 357 |
2018 | PAC DRILLING LLC | 3047.00 | 105.00 | 357 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | PAC DRILLING LLC | Brine | 0 | 301 |
2009 | PAC DRILLING LLC | Brine | 0 | 348 |
2010 | PAC DRILLING LLC | Brine | 0 | 341 |
2011 | PAC DRILLING LLC | Brine | 0 | 339 |
2012 | PAC DRILLING LLC | Brine | 63 | 390 |
2013 | PAC DRILLING LLC | Brine | 21 | 360 |
2014 | PAC DRILLING LLC | Brine | 31 | 360 |
2015 | PAC DRILLING LLC | Brine | 36 | 363 |
2016 | PAC DRILLING LLC | Brine | 0 | 357 |
2017 | PAC DRILLING LLC | Brine | 17 | 357 |
2018 | PAC DRILLING LLC | Brine | 0 | 357 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1542263585 | 2019-2-4 0:00:0 | UP | No Violations | 0.50 |
-1841463264 | 2012-9-5 0:00:0 | UP | No Violations | 0.50 |
-1909799072 | 2017-3-17 0:00: | UP | No Violations | 0.80 |
0471627425 | 2016-11-07 | UrbanProduction Wells | No Violations
On 12/13/2016, Northeast Regional Supervisor Tom Hill and I met with Justin Caldwell, co-owner of PAC Drilling, and Rusty Hornhill, well tender for PAC Drilling concerning the missing required urban safety equipment on 31 PAC Drilling wells in Hubbard and Liberty Townships. Mr. Caldwell has been given a document listing the wells with the missing the urban safety equipment. PAC Drilling is to submit a schedule for equipment installation for review and approval by the Division of Oil & Gas. | |
1003043058 | 2019-7-2 0:00:0 | UP | No Violations | |
1542263585 | 2019-02-04 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up for compliance notice 2052828854, regarding multiple compliance notices related to urban rule requirements. At the time of this inspection, the production tank was still missing the required urban safety equipment, i.e spark arrestor and pressure relief valve, and needs installed as required by 1501:9-9-05E(4)(b-e). A charcoal filter has been installed on the 210 BBL production tank. There was a locked chain link fence surrounding the tank battery; however, the fencing was 6 feet in height and needs to be 8 foot minimum. The top of the production tanks extend more than 3 foot above the fence and needs modified as required by 1501:9-9-05E(4)(f). The identification sign was missing the required information per 1501:9-9-05E(1)(a-e). No landscaping has been installed around the tank battery and was not waived during the pre-site inspection. The required access gate was not installed and was not waived during the pre-site inspection. Install the required gate with a lock at the access entrance per 1501:9-9-05E(2), and post the proper identification sign on the access gate per 1501:9-9-05E(1)(f).
PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 3) Install the required gate with a lock at the access road entrance per 1501:9-9-05(E)(2)(c). 4) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f). 5) Complete the required landscaping at the tank battery per 1501:9-9-05(E)(6)(a-c). 6) Install the required urban safety equipment on the production tank per 1501:9-9-05E(4)(b-e). Low-pressure relief valve and spark arrestor. |
1548472876 | 2019-11-18 0:00 | UP | No Violations | |
1841463264 | 2012-09-05 | UrbanProduction Wells | No Violations | I completed an urban production well inspection. My inspection found the well was equipped with a plunger lift unit (rabbit) that was in good condition. The tank battery was surrounded by a chain link fence and contained one 210 barrel oil barrel storage tank, one 50 barrel brine storage tank, a separator, and the proper identification. I noticed no visible spills or leaks. The lease road was in good condition. There are no violations at this time. |
1904548518 | 2020-4-15 0:00: | UP | No Violations | |
1909799072 | 2017-03-17 | UrbanProduction Wells | No Violations
-up lines have plugs, but are missing locks. The 210 bbl. storage tank is missing the required urban safety equipment. There is an identification sign posted at the tank battery. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a--site inspection. The equipment on the pad consists of the following:
| |
1962288638 | 2011-09-16 | Preliminary Restoration | No Violations | Preliminary Restoration was completed. |
2052828854 | 2018-05-14 | UrbanProduction Wells | Violations Noted | At the time of this inspection, the well was equipped with a plunger lift assembly. The annulus and flow line valves were open. There was an identification posted at the well, and was surrounded by a locked fence. The diked tank battery has two storage tanks and a separator. The pick-up lines are secure with the valve handles removed and plugs. The production tank was missing the required urban safety equipment, and needs installed as required by 1501:9-9--e). There was a locked chain link fence surrounding the tank battery; however, the fencing was 6 feet in height and needs to be 8 foot minimum. The top of the production tanks extend more than 3 foot above the fence and needs modified as required by 1501:9-9--9--e). No landscaping was installed around the tank battery, however the tank battery was located in a wooded area. The access was stable. The required access gate was not installed and was not waived during the pre-site inspection. Install the required gate with a lock at the access road entrance per 1501:9-9--9- |
471627425 | 2016-11-7 0:00: | UP | No Violations | 0.50 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
2052828854 | US-OH-120908 | 2018-06-05 | 9-05E1 | ID (a-i) |
2052828854 | US-OH-120909 | 2018-06-05 | 9-05E2 | FENCING (a-d) |
2052828854 | US-OH-120910 | 2018-06-05 | 9-05E4 | TANKS (a-i) |
For data sources see[8]