Well ID: 34-155-23895 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.15,"lon":-80.62,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Liberty Township | |
Operator Name: PAC DRILLING LLC | |
Well Pad ID: | |
Farm/Lease Name: WALLEY | |
License Status: Producing | |
License Date: 2008-01-08 | |
Spud Date: 2008-01-24 | |
Spud Drilling Contractor: KILBARGER DRLG | |
Final Drill Date: 2008-01-29 | |
Well Total Depth: 5293.00 ft | |
Configuration: Vertical | |
Latitude: 41.150000 | |
Longitude: -80.620000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2008-01-08 | Proposed Formations:CLINTON, Issued Date:1/8/2008, Expired Date:1/7/2009 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2008-01-29 | |
Completion Report Received | 2008-03-18 | |
Construction Permit Expires | 2009-01-07 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-07-01 | 5036 | 5082 | 56 |
5036 | 5082 | 56 | |
5036 | 5082 | 56 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 0 | 50000 | FRAC WATER VOLUME NOT REPORTED ON WCR… |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2009 | PAC DRILLING LLC | 23194.00 | 338.00 | 317 |
2010 | PAC DRILLING LLC | 17086.00 | 235.00 | 335 |
2011 | PAC DRILLING LLC | 8406.00 | 207.00 | 323 |
2012 | PAC DRILLING LLC | 4618.00 | 187.00 | 324 |
2013 | PAC DRILLING LLC | 3728.00 | 179.00 | 365 |
2014 | PAC DRILLING LLC | 2583.00 | 158.00 | 360 |
2015 | PAC DRILLING LLC | 3808.00 | 99.00 | 360 |
2016 | PAC DRILLING LLC | 2654.00 | 83.00 | 355 |
2017 | PAC DRILLING LLC | 2017.00 | 140.00 | 355 |
2018 | PAC DRILLING LLC | 1941.00 | 91.00 | 355 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2009 | PAC DRILLING LLC | Brine | 0 | 317 |
2010 | PAC DRILLING LLC | Brine | 0 | 335 |
2011 | PAC DRILLING LLC | Brine | 0 | 323 |
2012 | PAC DRILLING LLC | Brine | 41 | 324 |
2013 | PAC DRILLING LLC | Brine | 0 | 365 |
2014 | PAC DRILLING LLC | Brine | 0 | 360 |
2015 | PAC DRILLING LLC | Brine | 0 | 360 |
2016 | PAC DRILLING LLC | Brine | 0 | 355 |
2017 | PAC DRILLING LLC | Brine | 54 | 355 |
2018 | PAC DRILLING LLC | Brine | 19 | 355 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1983564710 | 2020-5-14 0:00: | UP | No Violations | |
0475106117 | 2018-07-16 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up for compliance notice 1526659484. At the time of this inspection, Inside the diked tank battery the pick-up lines have plugs, but still no locks. Locks need installed on the tank valves and pick-up lines or the handles removed. The identification sign posted at the tank battery still needs the required information per 1501:9-9--e). Landscaping has not been installed around the tank battery; however, it was located in a wooded area and not visible from Logan Gate Road. There was no gate installed at the lease access and still needs to be installed. |
0534303109 | 2017-03-13 | UrbanProduction Wells | No Violations
-up lines have plugs, but locks are missing. The required urban safety equipment has been installed on the production tank. There is an identification sign posted at the tank battery. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a--site inspection. The equipment on the pad consists of the following:
| |
0656627202 | 2012-01-10 | UrbanPreliminary Restoration | No Violations | The Preliminary Restoration was completed and acceptable. |
1125298757 | 2019-03-05 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up for compliance notice 1526659484, regarding multiple compliance issues related to urban rule requirements. At the time of this inspection, the pick-up lines and tank valves have plugs, but still no locks. Locks need installed on the tank valves and pick-up lines or the handles removed. The identification posted at the tank battery has been amended with the required information per 1501:9-9-05E(1)(a-e). Landscaping has not been installed around the tank battery; however, it was located in a wooded area and not visible from Logan Gate Road. There was no gate installed at the lease access and still needs to be installed.
PAC needs to: 1) Add locks to the tank valves and pick-up lines or remove the handles in the tank battery. 2) Install the required gate with a lock at the access road entrance per 1501:9-9-05(E)(2)(c). 3) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f). 4) Install the landscaping at the tank battery per 1501:9-9-05E(6)(a-c). |
1239208603 | 2009-01-20 | Drill / Deepen / Reopen | No Violations | Capstar drilling at 5012 . |
1351180460 | 2012-10-25 | UrbanPreliminary Restoration | No Violations | I conducted an Urban Preliminary Restoration inspection. My inspection found the well equipped with a plunger lift unit surrounded by a chain link fence. The tank battery was surrounded by a chain link fence, the proper dike, and contained one, 210 barrel oil storage tank with no carbon filter, lightning arrestor, and low pressure relief valve, one, 50 barrel brine storage tank, a separator, and the proper identification sign. I noticed no visible spills or leaks. The lease road was in good condition. I called office for PAC Drilling at 330-874-3781 and request the missing equipment for the storage tank be installed immediately to meet the Ohio Revised Code (ORC) 1501:9-9-5 under urban requirements. I will re-inspect by 11/25/2012. |
1472668599 | 2013-03-05 | UrbanPreliminary Restoration | No Violations | My inspection found the well site graded and vegetation growing. The pits were filled and debris removed. The well was equipped with a plunger lift unit. It was surrounded by a locked chain link fence with the proper identification sign. The tank battery contained one, 210 barrel production tank, one, 50 barrel brine tank, and a separator. It was surrounded by a locked chain link fence with the proper identification sign. There was a plug on the load line. The required urban safety equipment was installed on the production tank. The dike met containment requirements. The well was in production with a 7 day chart inside the separator. The lease road was in good condition. |
1526659484 | 2018-05-11 | UrbanProduction Wells | Violations Noted | At the time of this inspection, the well was equipped with a plunger lift assembly. The annulus and flow line valves were open. A domestic gas supply was plumbed off of the wellhead with an open ball valve, two regulators, a drip tank and a gas meter. The well was fenced with a locked man door and had legible identification. The diked tank battery has two storage tanks and a separator. The pick-up lines have plugs, but no locks. Locks need installed on the tank valves and pick-up lines or the handles removed. The required urban safety equipment has been installed on the production tank. There was an identification sign posted at the tank battery but needs the required information per 1501:9-9--e). There was a locked chain link fence around the tank battery. There was no landscaping around the tank battery; however, it was located in a wooded area and not visible from Logan Gate Road. The access road was stable. There was no gate installed at the lease access and will need to be installed. |
1869720481 | 2017-09-07 | UrbanProduction Wells | No Violations
-up lines have plugs, but locks are missing. The required urban safety equipment has been installed on the production tank. There is an identification sign posted at the tank battery. There is a locked chain link fence around the tank battery. There is no landscaping around the tank battery; however, it is located in a wooded area and not visible from Logan Gate Road. The access road is in good repair. I spoke with Rusty Thornhill to add a lock to the fence at the well, remove the handles on the valves or add locks to the pick-up lines, and cut down the vegetation. | |
475106117 | 2018-7-16 0:00: | UP | No Violations | |
534303109 | 2017-3-13 0:00: | UP | No Violations | 0.60 |
656627202 | 2012-1-10 0:00: | UL | No Violations | |
967792627 | 2019-11-18 0:00 | UP | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1526659484 | US-OH-114609 | 2018-06-05 | 9-05E1 | ID (a-i) |
1526659484 | US-OH-114610 | 2018-06-05 | 9-05E2 | FENCING (a-d) |
1526659484 | US-OH-114611 | 2018-06-05 | 9-05E3 | LOCKS |