34-155-23911

Well Details

Well ID: 34-155-23911
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Johnston Township
Operator Name: AMERICAN ENERGY ASSOCIATES INC
Well Pad ID:
Farm/Lease Name: RATHBURN
License Status: Producing
License Date: 2008-04-11
Spud Date: 2008-04-10
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2008-04-15
Well Total Depth: 4554.00 ft
Configuration: Vertical
Latitude: 41.390000
Longitude: -80.700000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-04-11 Proposed Formations:CLINTON, Issued Date:4/11/2008, Expired Date:4/11/2009 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-04-15
Completion Report Received 2009-02-03
Construction Permit Expires 2009-04-11
Record Last Modified 2015-09-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-03-17 4325 4400 41
2009-03-17 4491 4492 2
4325 4400 41
4491 4492 2
4325 4400 41

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 50022 Gal 30000 FRAC ALSO TREATED THE MEDINA SANDSTONE

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 AMERICAN ENERGY ASSOCIATES INC 1493.00 43.00 365
2011 AMERICAN ENERGY ASSOCIATES INC 3228.00 125.00 365
2012 AMERICAN ENERGY ASSOCIATES INC 2712.00 0.00 366
2013 AMERICAN ENERGY ASSOCIATES INC 2028.00 42.00 365
2014 AMERICAN ENERGY ASSOCIATES INC 1324.00 0.00 365
2015 AMERICAN ENERGY ASSOCIATES INC 923.00 0.00 365
2016 AMERICAN ENERGY ASSOCIATES INC 657.00 0.00 365
2017 AMERICAN ENERGY ASSOCIATES INC 247.00 0.00 365
2018 AMERICAN ENERGY ASSOCIATES INC 0.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 AMERICAN ENERGY ASSOCIATES INC Brine 480 365
2011 AMERICAN ENERGY ASSOCIATES INC Brine 551 365
2012 AMERICAN ENERGY ASSOCIATES INC Brine 171 366
2013 AMERICAN ENERGY ASSOCIATES INC Brine 193 365
2014 AMERICAN ENERGY ASSOCIATES INC Brine 0 365
2015 AMERICAN ENERGY ASSOCIATES INC Brine 0 365
2016 AMERICAN ENERGY ASSOCIATES INC Brine 0 365
2017 AMERICAN ENERGY ASSOCIATES INC Brine 0 365
2018 AMERICAN ENERGY ASSOCIATES INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2044570107 2019-12-23 0:00 PW No Violations
-468514280 2015-8-17 0:00: PW No Violations 0.50
-51302149 2020-6-15 0:00: PW No Violations
0249352751 2017-06-22 Production Wells No Violations

-up line is secure with a plug. An identification sign is posted. The access road is in good repair.

The equipment on site:



0468514280 2015-08-17 Production Wells No Violations I was on location for a status check. During my inspection, I found the well in production. The well is equipped with a plunger lift assembly. The tank battery consists of a 100 barrel production tank, a 50 barrel, poly brine tank, and a vertical, mechanical separator. A dike surround the tank battery. An identification sign is properly posted. There is a plug on the load line. The lease road is in stable condition.
0924124286 2009-12-08 Preliminary Restoration No Violations no violations .
1150375775 2013-04-08 Production Wells No Violations My inspection found the well in production. The well was equipped with a plunger lift unit. The tank battery contained one, 100 barrel production tank, one, 50 barrel brine tank, and a separator. It was surrounded by a slightly weathered dike; however, it meetings containment requirements. There was a plug on the load line and an identification sign on the production tank. The lease road was in good condition.
1229174628 2017-12-29 Production Wells No Violations I was on location to assess Chiefs Order 2017-274. I found the well in production with an open ball valve on the tubing for the plunger lift assembly. There is a chart box and 7 day chart dated 12/26/2017 on the sales line after the separator. The diked tank battery consists of two storage tanks and a separator. There is an identification sign posted. I spoke with Bob Barnett from American Energy Associates. Mr. Barnett stated the company does have insurance and will call Columbus ODNR on 1/2/2018 to correct the issue.

American Energy needs to: Immediately shut-in production well Submit updated Liability Insurance

1515166544 2018-01-04 Production Wells No Violations Shannon Mullins and I performed a complaint notice follow up #5765 and Chief Order Follow up 2017-274. The well is equipped with a plunger lift valves are open the pressure gage on the 4.5 casing shows 1400 psi. Tank battery is equipped with one 100 bbl tank and one 35 bbl poly tank and on e vertical separator ID sign are posted. Dike and Lease Road are stable.
1587476656 2020-4-21 0:00: PW No Violations
249352751 2017-6-22 0:00: PW No Violations 0.40
924124286 2009-12-8 0:00: PL No Violations

For data sources see[9]

References