Well ID: 34-155-23923 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.17,"lon":-80.62,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Liberty Township | |
Operator Name: PAC DRILLING LLC | |
Well Pad ID: | |
Farm/Lease Name: DELLIQUADRI | |
License Status: Producing | |
License Date: 2008-06-03 | |
Spud Date: 2008-07-16 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2008-07-24 | |
Well Total Depth: 5372.00 ft | |
Configuration: Vertical | |
Latitude: 41.170000 | |
Longitude: -80.620000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2008-06-03 | Proposed Formations:CLINTON, Issued Date:6/3/2008, Expired Date:6/3/2009 6:00:00 AM, Drilling unit acres:53.01, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2008-07-24 | |
Completion Report Received | 2009-03-06 | |
Construction Permit Expires | 2009-06-03 | |
Correction to Well | 2015-01-02 | UNIT SIZE CHANGED TO 40.89 ACRES. |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2009-06-04 | 5066 | 5156 | 49 |
5066 | 5156 | 49 | |
5066 | 5156 | 49 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 20 | 0 | 50000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | PAC DRILLING LLC | 7970.00 | 580.00 | 89 |
2009 | PAC DRILLING LLC | 25080.00 | 1562.00 | 348 |
2010 | PAC DRILLING LLC | 22756.00 | 851.00 | 336 |
2011 | PAC DRILLING LLC | 9742.00 | 770.00 | 339 |
2012 | PAC DRILLING LLC | 6067.00 | 633.00 | 361 |
2013 | PAC DRILLING LLC | 6243.00 | 533.00 | 365 |
2014 | PAC DRILLING LLC | 4346.00 | 337.00 | 360 |
2015 | PAC DRILLING LLC | 3332.00 | 219.00 | 364 |
2016 | PAC DRILLING LLC | 2770.00 | 303.00 | 356 |
2017 | PAC DRILLING LLC | 3081.00 | 410.00 | 357 |
2018 | PAC DRILLING LLC | 3039.00 | 261.00 | 357 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | PAC DRILLING LLC | Brine | 0 | 89 |
2009 | PAC DRILLING LLC | Brine | 0 | 348 |
2010 | PAC DRILLING LLC | Brine | 0 | 336 |
2011 | PAC DRILLING LLC | Brine | 42 | 339 |
2012 | PAC DRILLING LLC | Brine | 66 | 361 |
2013 | PAC DRILLING LLC | Brine | 0 | 365 |
2014 | PAC DRILLING LLC | Brine | 75 | 360 |
2015 | PAC DRILLING LLC | Brine | 46 | 364 |
2016 | PAC DRILLING LLC | Brine | 0 | 356 |
2017 | PAC DRILLING LLC | Brine | 0 | 357 |
2018 | PAC DRILLING LLC | Brine | 8 | 357 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-168593988 | 2016-1-21 0:00: | UP | No Violations | 0.50 |
-418341819 | 2020-9-4 0:00:0 | UP | No Violations | |
-462768026 | 2011-9-29 0:00: | PL | No Violations | |
0123202384 | 2018-05-16 | UrbanProduction Wells | Violations Noted | At the time of this inspection, the well was equipped with a plunger lift assembly. The annulus and flow line valves were open. A domestic gas supply was plumbed off of the wellhead with an open ball valve, a regulator and a gas meter. There was an identification posted at the well, but the well was not fenced. The well was located in a woodland area and approximately 600 feet from nearest private residence. The tank battery has two storage tanks and a separator. The pick-up lines have plugs and the valve handles have been removed. The required urban safety equipment was missing from the production tank. There was an identification sign posted at the tank battery, but was missing the required information per 1501:9-9-05(E)(1)(a-e). There was a locked chain link fence around the tank battery. The 210 BBL storage tank extends more than 3 foot above the top of the fencing. The access road was stable. The access road gate was waived during the pre-
PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 3) Install urban safety equipment on the production tank as required by 1501:9-9-05(E)(4)(b-e): Activated charcoal filters. Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor. |
0168593988 | 2016-01-21 | UrbanProduction Wells | No Violations | I was on location for a status check. During my inspection, I found the well in production. The well is equipped with a plunger lift assembly. A domestic gas line comes off of the wells 4.5 casing. The tank battery has a 210 barrel production tank, a 50 barrel, poly brine tank and a mechanical separator. A dike surrounds the tank battery. Identification signs are posted at the well and tank battery. A locked, chain, link fence surrounds the tank battery. The lease road is in stable condition. |
0462768026 | 2011-09-29 | Preliminary Restoration | No Violations | Preliminary Restoration was completed and meets all requirements. |
0713944596 | 2017-03-13 | UrbanProduction Wells | No Violations
-up lines have plugs and the valve handles have been removed. The required urban safety equipment is missing from the production tank. There is an oil stain on the south side of the production tank with no impact to the surface area. There is an identification sign posted at the tank battery. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a-- The equipment on the pad consists of the following:
| |
123202384 | 2018-5-16 0:00: | UP | No Violations | |
1481815017 | 2016-10-24 | UrbanProduction Wells | No Violations
On 12/13/2016, Northeast Regional Supervisor Tom Hill and I met with Justin Caldwell, co-owner of PAC Drilling, and Rusty Hornhill, well tender for PAC Drilling concerning the missing required urban safety equipment on 31 PAC Drilling wells in Hubbard and Liberty Townships. Mr. Caldwell has been given a document listing the wells with the missing the urban safety equipment. PAC Drilling is to submit a schedule for equipment installation for review and approval by the Division of Oil & Gas. | |
2066133868 | 2008-07-16 | Drill / Deepen / Reopen | No Violations | Capstar moving on site . |
2092663569 | 2019-02-25 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 123202384. At the time of this inspection, the following items have been addressed: the required urban safety equipment has been installed on the production tank and identification posted at the tank battery, now has the required information per 1501:9-9-05(E)(1)(a-e). The following items still need addressed in order to put the site back into compliance.
PAC needs to: 1) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 2) Install fencing around the well. |
2105586733 | 2020-3-31 0:00: | UP | No Violations | |
713944596 | 2017-3-13 0:00: | UP | No Violations | 0.60 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0123202384 | US-OH-106241 | 2018-06-05 | 9-05E1 | ID (a-i) |
0123202384 | US-OH-106242 | 2018-06-05 | 9-05E2 | FENCING (a-d) |
0123202384 | US-OH-106243 | 2018-06-05 | 9-05E4 | TANKS (a-i) |