X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-23961

Well Details

Well ID: 34-155-23961
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hubbard Township
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: COCHRAN
License Status: Producing
License Date: 2008-09-23
Spud Date: 2008-10-02
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2008-10-08
Well Total Depth: 5340.00 ft
Configuration: Vertical
Latitude: 41.160000
Longitude: -80.590000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-09-23 Proposed Formations:CLINTON/MEDINA, Issued Date:9/23/2008, Expired Date:9/23/2009 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-10-08
Completion Report Received 2009-03-06
Construction Permit Expires 2009-09-23
Record Last Modified 2015-09-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-06-04 5026 4130 42
2009-06-04 5180 5187 8
5026 4130 42
5180 5187 8
5026 4130 42

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 20 0 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 PAC DRILLING LLC 2259.00 0.00 33
2009 PAC DRILLING LLC 24464.00 498.00 349
2010 PAC DRILLING LLC 18771.00 128.00 313
2011 PAC DRILLING LLC 8208.00 219.00 317
2012 PAC DRILLING LLC 4272.00 173.00 358
2013 PAC DRILLING LLC 3757.00 83.00 365
2014 PAC DRILLING LLC 2398.00 80.00 360
2015 PAC DRILLING LLC 3335.00 92.00 360
2016 PAC DRILLING LLC 2133.00 68.00 354
2017 PAC DRILLING LLC 1935.00 64.00 354
2018 PAC DRILLING LLC 2077.00 0.00 355

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 PAC DRILLING LLC Brine 0 33
2009 PAC DRILLING LLC Brine 0 349
2010 PAC DRILLING LLC Brine 0 313
2011 PAC DRILLING LLC Brine 123 317
2012 PAC DRILLING LLC Brine 57 358
2013 PAC DRILLING LLC Brine 59 365
2014 PAC DRILLING LLC Brine 0 360
2015 PAC DRILLING LLC Brine 38 360
2016 PAC DRILLING LLC Brine 0 354
2017 PAC DRILLING LLC Brine 0 354
2018 PAC DRILLING LLC Brine 0 355

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2132527810 2017-10-16 0:00 UP No Violations 0.50
-391873777 2020-5-14 0:00: UP No Violations
-912654120 2011-9-13 0:00: PL No Violations
0106304800 2016-11-07 UrbanProduction Wells No Violations


PAC Drilling will: Install the required safety equipment


-pressure relief valve


The equipment on the site consists of the following:



On 12/13/2016, Northeast Regional Supervisor Tom Hill and I met with Justin Caldwell, co-owner of PAC Drilling, and Rusty Hornhill, well tender for PAC Drilling concerning the missing required urban safety equipment on 31 PAC Drilling wells in Hubbard and Liberty Townships. Mr. Caldwell has been given a document listing the wells with the missing the urban safety equipment. PAC Drilling is to submit a schedule for equipment installation for review and approval by the Division of Oil & Gas.

0912654120 2011-09-13 Preliminary Restoration No Violations Preliminary Restoration was completed and meets all requirements.
106304800 2016-11-7 0:00: UP No Violations 0.50
1226247720 2012-01-10 UrbanPreliminary Restoration No Violations The preliminary restoration was completed and acceptable.
1527009504 2018-05-14 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 213527810. The well was equipped with a plunger lift assembly and the annulus and flow line valves were open. A domestic gas supply was plumbed off of the wellhead. No identification was posted at the well. No fencing was installed around the well and was not waived during the pre-site inspection. The diked tank battery has two storage tanks and a separator. The pick-up line was secure with a plug and lock. The required urban safety equipment still had not been installed per 1501:9-9-05(E)(4)(b-e). There was an identification sign posted at the tank battery, but was still missing the required information per 1501:9-9-05(E)(1)(a-e). There is a locked chain link fence surrounding the tank battery. The 210 BBL tank extends more than 3 foot above the fencing. The access was stable but no gate has been installed, at the entrance. Install the required gate with a lock at the access road entrance per 1501:9-9--9-
1688554465 2017-03-17 UrbanProduction Wells No Violations

--up lines have plugs, but are missing locks. The 210 bbl. storage tank is missing the required urban safety equipment. There is an oil stain on the south side of the 210 bbl. storage tank. There is an identification sign posted at the tank battery. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a--site inspection.

The equipment on the pad consists of the following:



1702534944 2019-03-05 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 213527810, regarding multiple compliance issues related to urban rule requirements. Identification still needs posted at the well. No fencing was installed around the well and was not waived during the pre-site inspection. The required urban safety equipment still had not been installed per 1501:9-9-05(E)(4)(b-e). There was an identification sign posted at the tank battery, but was still missing the required information per 1501:9-9-05(E)(1)(a-e). There is a locked chain link fence surrounding the tank battery. The 210 BBL tank extends more than 3 foot above the fencing. The access had a chain across it, but a locked gate is still required to be installed with proper identification. Install the required gate with a lock at the access road entrance per 1501:9-9-05E(2) and add the identification at the gate per 1501:9-9-05E(1)(f).

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05E(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05E(4)(f). 3) Install the required gate with a lock at the access road entrance per 1501:9-9-05(E)(2)(c). 4) Post the proper identification sign on the access road gate per 1501:9-9-05E(1)(f). 5) Install the fencing around the well and install indentification. 6) Install the required urban safety equipment, spark arrestor, low-pressure relief valve and charcoal filter, per 1501:9-9-05(E)(4)(b-e).

1768971003 2012-09-05 UrbanProduction Wells No Violations I completed an urban production well inspection. My inspection found the well was equipped with a plunger lift unit (rabbit) that was in good condition. The tank battery was surrounded by a chain link fence and contained one 210 barrel oil barrel storage tank, one 50 barrel brine storage tank, a separator, and the proper identification posted. I noticed no visible spills or leaks. The lease road was in good condition. There are no violations at this time.
2132527810 2017-10-16 UrbanProduction Wells Violations Noted

--up line is secure with a plug and lock. The 210 bbl. storage tank is missing the required urban safety equipment. There is an identification sign posted at the tank battery. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a--site inspection.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install urban safety equipment on the production tank as required by 1501:9-9-05(E)(4)(b-e): Activated charcoal filters. Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor. -9-05(E)(2)

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
2132527810 US-OH-121859 2017-12-26 ID (a-i)
2132527810 US-OH-121860 2017-12-26 FENCING (a-d)
2132527810 US-OH-121861 2017-12-26 TANKS (a-i)

For data sources see[9]

References