X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-23973

Well Details

Well ID: 34-155-23973
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Liberty Township
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: GRYMBERG UNIT
License Status: Producing
License Date: 2008-10-20
Spud Date: 2008-10-22
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2008-10-29
Well Total Depth: 5339.00 ft
Configuration: Vertical
Latitude: 41.180000
Longitude: -80.650000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-10-20 Proposed Formations:CLINTON, Issued Date:10/20/2008, Expired Date:10/20/2009 6:00:00 AM, Drilling unit acres:48.33, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-10-29
Correction to Well 2008-12-12 UNIT SIZE DECREASED TO 47.35 ACRES.
Completion Report Received 2009-03-06
Construction Permit Expires 2009-10-20
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-06-04 5042 5090 35
5042 5090 35
5042 5090 35

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 20 0 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 PAC DRILLING LLC 609.00 0.00 15
2009 PAC DRILLING LLC 23414.00 362.00 341
2010 PAC DRILLING LLC 20479.00 195.00 349
2011 PAC DRILLING LLC 9652.00 104.00 335
2012 PAC DRILLING LLC 4799.00 183.00 354
2013 PAC DRILLING LLC 3469.00 94.00 365
2014 PAC DRILLING LLC 3653.00 73.00 360
2015 PAC DRILLING LLC 4576.00 94.00 360
2016 PAC DRILLING LLC 2618.00 74.00 355
2017 PAC DRILLING LLC 3337.00 46.00 357
2018 PAC DRILLING LLC 3129.00 113.00 357

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 PAC DRILLING LLC Brine 0 15
2009 PAC DRILLING LLC Brine 0 341
2010 PAC DRILLING LLC Brine 43 349
2011 PAC DRILLING LLC Brine 41 335
2012 PAC DRILLING LLC Brine 22 354
2013 PAC DRILLING LLC Brine 0 365
2014 PAC DRILLING LLC Brine 0 360
2015 PAC DRILLING LLC Brine 42 360
2016 PAC DRILLING LLC Brine 0 355
2017 PAC DRILLING LLC Brine 0 357
2018 PAC DRILLING LLC Brine 20 357

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1187435567 2011-9-7 0:00:0 UP No Violations
-1314294343 2019-3-1 0:00:0 UP No Violations
-1652839158 2018-7-16 0:00: UP No Violations
-2085390512 2017-8-21 0:00: UP No Violations 0.50
-862096866 2012-4-9 0:00:0 UP No Violations
0223783154 2017-12-18 UrbanProduction Wells No Violations I found the handles removed from the pick--up line is still missing.

PAC still needs to: Replace or repair the wooden fence around the well. Install the urban safety equipment on the production tank. Install keep out/danger sign. Install identification sign on the access road gate.

0710250642 2018-05-11 UrbanProduction Wells Violations Noted At the time of this inspection, the well was equipped with a plunger lift assembly. The gate valve and the 2 inch flow line valves were open. A domestic gas supply comes off the wellhead with a 2 inch flow line, two regulators, a drip tank and meter. Half of the wooden fence panels around the well are completely missing, leaning against the existing fence or lying on the ground behind the existing fence. There was signage located at the well. The diked tank battery has two tanks and a separator. The 4 inch pick-up line on the production tank was missing a bull plug and lock. The handles have been removed from the tank valves and pick-up lines. A locked chain link fence surrounds the tank battery. The fence needs 3 strand barb wire added to the top. An identification sign was posted on the stairs for the production tank. The identification sign was missing the required information per 1501:9-9--e). The danger, keep out and no smoking sign(s) were missing. There was no urban safety equipment installed on the production tank. The tank battery was located within 200 feet of a church to the north and 250 feet from a private residence to the southeast. There was no landscaping at the tank battery; however, the tank battery was approximately positioned over 900 feet from Sodom Hutchings Road in the woods. The access was stable, with a locked gate at the entrance. There is no identification sign posted on the gate as required by 1501:9-9-
0862096866 2012-04-09 UrbanProduction Wells No Violations My follow-up inspection of this well site found that the fences were not installed around the wellhead and tank battery.
1079676559 2011-09-07 UrbanProduction Wells No Violations FOLLOW UP TO NOV # -1187435567 An inspection was initiated by a water well complaint. There was no evidence of contamination found.

The well was found without identification and required locks.

Jason Caldwell was notified in person.

1174010047 2019-7-2 0:00:0 UP No Violations
1187435567 2011-09-07 UrbanProduction Wells Violations Noted An inspection was initiated by a water well complaint. There was no evidence of contamination found.

The well was found without identification and required locks.

Jason Caldwell was notified in person.

1314294343 2019-03-01 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 710250642, regarding multiple compliance issues related to urban rule requirements. At the time of this inspection, the well fence has not been repaired and signage has not been added. The tank battery fence still needs 3 strand barb wire added to the top. The posted identification has been amended with the required information per 1501:9-9-05E(1)(a-e). The urban safety equipment still needs installed on the production tank. The access gate was locked at the entrance, and has had identification sign posted as required by 1501:9-9-05E(1)(f).

PAC needs to: 1) Install the required urban safety equipment per 1501:9-9-05(E)(4)(a-e): Activated charcoal filter. Functioning low-pressure relief valve. Tank hatch shall have a functioning seal and the hatch shall be secure at all times. Functioning lightning arrestor. 2) Install the 3 strand barb on the tank battery fencing. 3) Repair the well fencing and add identification at the well location.

1403789846 2014-06-26 UrbanPreliminary Restoration No Violations I was on location for a preliminary restoration inspection. I found during my inspection the site graded. Vegetation was well established. The pits were filled and closed. All drilling equipment was removed from the location. Drainage and erosion controls were in place and working properly. There was a locked, chain link fence surrounding the production equipment. The properly safety equipment was installed on the production tank. An identification sign was posted. The lease road was in stable condition with a locked gate at the entrance. Preliminary restoration passed.
1489501169 2017-02-21 UrbanProduction Wells No Violations

--up line. A locked chain link fence surrounds the tank battery. An identification sign is posted on the stairs for the production tank. The identification sign is missing the required information per 1501:9-9---9-

The equipment on the pad consists of the following:



1652839158 2018-07-16 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 710250642. At the time of this inspection, the well fence has not been repaired and signage has not been added. The 4 inch pick-up line on the production tank has had a bull plug added and handle removed. The tank battery fence still needs 3 strand barb wire added to the top. The posted identification sign was still missing the required information per 1501:9-9--e). The danger, keep out and no smoking sign(s) were missing. The urban safety equipment still needs installed on the production tank. The access gate was locked at the entrance, but still needs an identification sign posted as required by 1501:9-9-
2085390512 2017-08-21 UrbanProduction Wells No Violations

--up line. A locked chain link fence surrounds the tank battery. An identification sign is posted on the stairs for the production tank. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a--9-05(E)(1)(f).

223783154 2017-12-18 0:00 UP No Violations 0.40
710250642 2018-5-11 0:00: UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0710250642 US-OH-128024 2018-05-25 9-05E1 ID (a-i)
0710250642 US-OH-128025 2018-05-25 9-05E2 FENCING (a-d)
0710250642 US-OH-128026 2018-05-25 9-9-02 General Safety
1187435567 US-OH-104978 2013-04-22 ID (a-i)
1187435567 US-OH-104979 2013-04-22 LOCKS

For data sources see[9]

References