34-155-23974

Well Details

Well ID: 34-155-23974
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hubbard Township
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: HUDACK
License Status: Producing
License Date: 2008-10-20
Spud Date: 2008-11-06
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2008-11-12
Well Total Depth: 5308.00 ft
Configuration: Vertical
Latitude: 41.170000
Longitude: -80.580000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-10-20 Proposed Formations:CLINTON/MEDINA, Issued Date:10/20/2008, Expired Date:10/20/2009 6:00:00 AM, Drilling unit acres:236.73, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-11-12
Completion Report Received 2009-03-06
Construction Permit Expires 2009-10-20
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-06-04 5001 5100 35
5001 5100 35
5001 5100 35

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 20 0 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 PAC DRILLING LLC 21700.00 514.00 305
2010 PAC DRILLING LLC 23068.00 431.00 353
2011 PAC DRILLING LLC 10124.00 284.00 346
2012 PAC DRILLING LLC 7660.00 203.00 364
2013 PAC DRILLING LLC 5524.00 217.00 365
2014 PAC DRILLING LLC 4974.00 165.00 360
2015 PAC DRILLING LLC 4155.00 152.00 360
2016 PAC DRILLING LLC 2656.00 131.00 358
2017 PAC DRILLING LLC 2355.00 86.00 358
2018 PAC DRILLING LLC 2614.00 74.00 359

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 PAC DRILLING LLC Brine 0 305
2010 PAC DRILLING LLC Brine 52 353
2011 PAC DRILLING LLC Brine 34 346
2012 PAC DRILLING LLC Brine 41 364
2013 PAC DRILLING LLC Brine 0 365
2014 PAC DRILLING LLC Brine 44 360
2015 PAC DRILLING LLC Brine 0 360
2016 PAC DRILLING LLC Brine 0 358
2017 PAC DRILLING LLC Brine 0 358
2018 PAC DRILLING LLC Brine 14 359

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1080472782 2011-9-1 0:00:0 PL No Violations
-1250172745 2008-11-10 0:00 DD No Violations
-1389513278 2018-5-14 0:00: UP No Violations
-1743107803 2019-3-1 0:00:0 UP No Violations
-2146580753 2012-7-30 0:00: UP No Violations 0.50
1080472782 2011-09-01 Preliminary Restoration No Violations Preliminary Restoration was completed.
1250172745 2008-11-10 Drill / Deepen / Reopen No Violations no violations .
1389513278 2018-05-14 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1845637045. At the time of this inspection, the well was equipped with a plunger lift assembly. The annulus and flow line valves were open. An identification sign was posted at the well. There was no fencing around the well. The well was located in an open field surround by woods, and not visible from Drummand Avenue. The diked tank battery has three storage tanks and a separator. The pick-up line has a plug and the ball valve handle has been removed. The 210 BBL storage tank was missing some the required urban safety equipment. An identification sign was posted at the tank battery. The identification sign was missing the required information per 1501:9-9---site inspection. The tank battery was shared with wells 2-3975 and 2-3977.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 3) Install urban safety equipment on the production tank as required by 1501:9-9-05(E)(4)(b-e): Activated charcoal filters. Functioning lightning arrestor. 4) Install the fencing around the well.

1451495487 2020-4-24 0:00: UP No Violations
1497967246 2017-04-20 UrbanProduction Wells No Violations

-up line has a plug and the ball valve handle has been removed. The 210 bbl. storage tank is missing the required urban safety equipment. An identification sign is posted at the tank battery. The identification sign is missing the required information per 1501:9-9---site inspection. The tank battery is share with permits 2-3975 and 2-3977.

The equipment on the pad consists of the following:



1743107803 2019-03-01 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1845637045, regarding multiple compliance issues relating to urban rule requirements. At the time of this inspection, No fencing has been installed around the well and has not been waived during the pre-site meeting. The 210 BBL production tanks have been outfitted with the required urban safety equipment. The identification posted at the tank battery, still needs amended with the required information per 1501:9-9-05E(1)(a-e). There was a locked chain link fence with 3 strand barb wire surrounding the tank battery. The production tank was 3 foot above the top of the fence. There was no landscaping at the tank battery.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 3) Install the fencing around the well.

1845637045 2016-07-21 UrbanProduction Wells Violations Noted

-3975 and 2-3977. I spoke with Rusty Hornhill, well tender for PAC Drilling, concerning the identification sign, the missing locks and the required safety equipment. A compliance notice has been issued.

PAC Drilling has 45 days to: Install the proper urban safety equipment.


-pressure relief valve

Post an identification sign at the well. Install locks on the load line ball valves on the production tanks.

The equipment on the site consists of the following:



2146580753 2012-07-30 UrbanProduction Wells No Violations On 7/30/2012, I completed an urban production well inspection status check. My inspection found the well was equipped with a plunger lift unit (rabbit) that was in good condition. The tank battery was surrounded by a chain link fence, shared with permit number 2-3975, and contained two 210 barrel oil storage tanks, one 50 barrel storage tank, a separator, and the proper identification. I noticed no visible spills or leaks. The lease road was in good condition. There are no violations at this time.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1845637045 US-OH-118436 2016-08-04 ID (a-i)
1845637045 US-OH-118437 2016-08-04 LOCKS
1845637045 US-OH-118438 2016-08-04 TANKS (a-i)

For data sources see[9]

References