34-155-23999

Well Details

Well ID: 34-155-23999
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Newton Township
Operator Name: J WELL SERVICE INC
Well Pad ID:
Farm/Lease Name: CARLETON
License Status: Producing
License Date: 2009-05-05
Spud Date: 2009-06-01
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2009-06-04
Well Total Depth: 4635.00 ft
Configuration: Vertical
Latitude: 41.190000
Longitude: -80.990000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-05-05 Proposed Formations:OHIO SHALE THRU MEDINA (CANNOT PRODUCE BEREA), Issued Date:5/5/2009, Expired Date:5/5/2010 6:00:00 AM, Drilling unit acres:49.61, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-06-04
Completion Report Received 2009-08-25
Construction Permit Expires 2010-05-05
Change of Owner 2016-08-08 Operator changed from 2456, OHIO VALLEY ENERGY SYSTEM CORP to 8738, J WELL SERVICE INC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-12-10 4400 4433 66
4400 4433 66
4400 4433 66

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 8 2645 Bbl 80000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 OHIO VALLEY ENERGY SYSTEMS COR 197.00 0.00 9
2010 OHIO VALLEY ENERGY SYSTEMS COR 2847.00 216.00 365
2011 OHIO VALLEY ENERGY SYSTEMS COR 1573.00 95.00 365
2012 OHIO VALLEY ENERGY SYSTEMS COR 1519.00 0.00 366
2013 OHIO VALLEY ENERGY SYSTEMS COR 1123.00 92.00 365
2014 OHIO VALLEY ENERGY SYSTEMS COR 938.00 52.00 365
2015 OHIO VALLEY ENERGY SYSTEMS COR 453.00 0.00 365
2016 OHIO VALLEY ENERGY SYSTEMS COR 322.00 0.00 98
2017 J WELL SERVICE INC 757.00 41.00 365
2018 J WELL SERVICE INC 833.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 OHIO VALLEY ENERGY SYSTEMS COR Brine 3420 9
2010 OHIO VALLEY ENERGY SYSTEMS COR Brine 427 365
2011 OHIO VALLEY ENERGY SYSTEMS COR Brine 376 365
2012 OHIO VALLEY ENERGY SYSTEMS COR Brine 170 366
2013 OHIO VALLEY ENERGY SYSTEMS COR Brine 50 365
2014 OHIO VALLEY ENERGY SYSTEMS COR Brine 100 365
2015 OHIO VALLEY ENERGY SYSTEMS COR Brine 107 365
2016 J WELL SERVICE INC Brine 0 180
2017 J WELL SERVICE INC Brine 37 365
2018 J WELL SERVICE INC Brine 28 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1333636956 2012-5-18 0:00: PW No Violations
-153628238 2015-8-31 0:00: PW No Violations 0.50
-277466294 2012-5-21 0:00: PW No Violations 0.50
0153628238 2015-08-31 Production Wells No Violations I was on location for a status check. During my inspection, I found the well in production. The well is equipped with a plunger lift assembly. The tank battery consists of a 100 barrel production tank, a 50 barrel, poly brine tank, and a mechanical separator. A dike surrounds the tank battery. Locked, chain link fences surround the well and tank battery. An identification sign is posted. There is a plug on the load line. The lease road is in stable condition.
0277466294 2012-05-21 Production Wells No Violations On 5/21/2012, I completed a follow-up inspection. My inspection found the dike had been repaired. Inspection passed.
1333636956 2012-05-18 Production Wells Violations Noted On 5/18/2012, I conducted a production well inspection status check. My inspection found a ditch dug on the west wall on the dike surrounding the tank batter. I called Don Nething from Ohio Valley Energy Systems at 330-283-1861 to inform him of the violation and the need for an immediated repair. Don informed me the well tender would be sent out that day (05/18/2012) to correct the violation. I will perform a follow-up inspection on 5/21/2012.
1343249567 2012-07-02 Preliminary Restoration No Violations On 7/2/2012, I completed a production well Preliminary Restoration inspection. My inspection found this well equipped with a plunger lift (rabbit) system. The tank battery contains one 100 barrel oil storage tank, with the proper identification posted, one 50 barrel brine tank, and a separator. The pits have been filled and fencing has been placed around the tank battery and well head. The well meets the Ohio Revised Code (ORC) Chapter 1509:9-9-5 requirements. Preliminary Restoration is passed.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1333636956 US-OH-109598 2012-05-21 General Safety

For data sources see[9]