Well ID: 34-155-24014 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.17,"lon":-80.64,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Liberty Township | |
Operator Name: PAC DRILLING LLC | |
Well Pad ID: | |
Farm/Lease Name: CAPESTRO | |
License Status: Producing | |
License Date: 2009-12-14 | |
Spud Date: 2009-12-29 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2010-01-05 | |
Well Total Depth: 5291.00 ft | |
Configuration: Vertical | |
Latitude: 41.170000 | |
Longitude: -80.640000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2009-12-14 | Proposed Formations:CLINTON/MEDINA, Issued Date:12/14/2009, Expired Date:12/14/2010 6:00:00 AM, Drilling unit acres:80, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2010-01-05 | |
Completion Report Received | 2010-06-01 | |
Construction Permit Expires | 2010-12-14 | |
Record Last Modified | 2017-10-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2010-08-03 | 5024 | 5066 | 48 |
5024 | 5066 | 48 | |
5024 | 5066 | 48 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 0 | 47500 | FLUID VOLUME OF FRAC NOT INDICATED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | PAC DRILLING LLC | 23084.00 | 906.00 | 325 |
2011 | PAC DRILLING LLC | 9461.00 | 563.00 | 356 |
2012 | PAC DRILLING LLC | 5964.00 | 324.00 | 355 |
2013 | PAC DRILLING LLC | 4532.00 | 294.00 | 365 |
2014 | PAC DRILLING LLC | 4092.00 | 214.00 | 360 |
2015 | PAC DRILLING LLC | 3968.00 | 197.00 | 363 |
2016 | PAC DRILLING LLC | 2953.00 | 179.00 | 358 |
2017 | PAC DRILLING LLC | 2636.00 | 157.00 | 359 |
2018 | PAC DRILLING LLC | 2855.00 | 101.00 | 359 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | PAC DRILLING LLC | Brine | 163 | 325 |
2011 | PAC DRILLING LLC | Brine | 94 | 356 |
2012 | PAC DRILLING LLC | Brine | 70 | 355 |
2013 | PAC DRILLING LLC | Brine | 44 | 365 |
2014 | PAC DRILLING LLC | Brine | 22 | 360 |
2015 | PAC DRILLING LLC | Brine | 44 | 363 |
2016 | PAC DRILLING LLC | Brine | 25 | 358 |
2017 | PAC DRILLING LLC | Brine | 0 | 359 |
2018 | PAC DRILLING LLC | Brine | 20 | 359 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-104193544 | 2010-1-6 0:00:0 | DD | No Violations | |
-1309788913 | 2017-10-11 0:00 | UP | No Violations | 0.40 |
-1480613558 | 2017-2-15 0:00: | UP | No Violations | 0.60 |
-1543439384 | 2018-5-11 0:00: | UP | No Violations | |
-1665615642 | 2010-1-12 0:00: | DD | No Violations | |
-39590475 | 2019-2-25 0:00: | UP | No Violations | |
-636659320 | 2016-1-21 0:00: | UP | No Violations | 0.70 |
0039590475 | 2019-02-25 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 1309788913, regarding the installation of identification at the road access gate and required lock on the gate, amended identification information at the tank battery, and install landscaping at the tank battery location, and fencing around the well. At the time of this inspection, the access gate identification and lock has been installed. The other above items have not been addressed.
PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Complete the required landscaping around the tank battery per 1501:9-9-05(E)(6)(a-c). 4) Fencing needs installed around the well. |
0104193544 | 2010-01-06 | Drill / Deepen / Reopen | No Violations | Capstar rigging up . |
0140003918 | 2013-03-05 | UrbanProduction Wells | No Violations | My inspection found the proper identification sign posted at the tank battery and well. The safety equipment was installed on the production tank. |
0636659320 | 2016-01-21 | UrbanProduction Wells | No Violations | I was on location for a status check. During my inspection, I found the well in production. The well is equipped with a plunger lift assembly. The tank battery has three, 210 barrel production tanks, two, 50 barrel, poly brine tanks and two, mechanical separators. There is a dike around the tank battery. Identification signs are posted at the well and tank battery. A locked, chain link fence surrounds the tank battery. The lease road is in stable condition. The tank battery is shared with permit number 2-4013 and 2-4012. |
1309788913 | 2017-10-11 | UrbanProduction Wells | Violations Noted
--up lines are secure with plugs and the handles have been removed from the valves. A locked chain link fence with barb wire surrounds the tank battery. An identification sign is posted on the chain link fence. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a-e). There is no landscaping at the tank battery; however, the tank battery and private residences are separated by a line of brush and trees. The access road is in good repair with a gate at the entrance. There is no identification sign on the gate. The tank battery and access road is shared with permit #2-4012 and #2-4013. PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f). 3) Complete the required landscaping on the south and west sides of the tank battery per 1501:9-9-05(E)(6)(a-c). 4) Install the required fencing with a lock around the wellhead per 1501:9-9-05(E)(2). | |
1315780737 | 2010-01-27 | Preliminary Restoration | No Violations | Drilling pits have benn closed . No violations . |
140003918 | 2013-3-5 0:00:0 | UP | No Violations | 0.50 |
1480613558 | 2017-02-15 | UrbanProduction Wells | No Violations
---9--e). There is no landscaping at the tank battery; however, the tank battery and private residences are separated by a line of brush and trees. The access road is in good repair. The access road gate was not waived during the pre-site inspection. The tank battery and access road is shared with permit #2-4012 and #2-4013. The equipment on the pad consists of the following:
| |
1543439384 | 2018-05-11 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up for compliance notice 1309788913. At the time of this inspection, the well was equipped with a plunger lift assembly. The annulus and flow line valves were open. There was an identification posted at the well, but no fence was installed around the well. The diked tank battery has three 210 BBL tanks, one 50 BBL tank and two mechanical separators. The pick-up lines are secure with the valve handles removed and plugs. The production tanks have the required urban safety equipment. There was a locked chain link fence surrounding the tank battery, with 3 strand barb at the top. The identification sign was missing the required information. No landscaping was installed around the tank battery. The tank battery was shared with wells 2-4012 and 2-4013. The access was stable. The required access gate was installed and needs a lock.
PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f). 3) Complete the required landscaping around the tank battery per 1501:9-9-05(E)(6)(a-c). 4) Install the required fencing with a lock around the wellhead per 1501:9-9-05(E)(2). |
1665615642 | 2010-01-12 | Drill / Deepen / Reopen | No Violations | Company logging well . No violations . |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1309788913 | US-OH-108777 | 2017-12-26 | ID (a-i) | |
1309788913 | US-OH-108778 | 2017-12-26 | FENCING (a-d) | |
1309788913 | US-OH-108779 | 2017-12-26 | LANDSCAPING (a-c) |