If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-24019 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.17,"lon":-80.63,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Liberty Township | |
Operator Name: PAC DRILLING LLC | |
Well Pad ID: | |
Farm/Lease Name: OBLATE SISTERS | |
License Status: Producing | |
License Date: 2010-03-10 | |
Spud Date: 2011-01-17 | |
Spud Drilling Contractor: G & H DRLG | |
Final Drill Date: 2011-01-22 | |
Well Total Depth: 5332.00 ft | |
Configuration: Vertical | |
Latitude: 41.170000 | |
Longitude: -80.630000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2010-03-10 | Proposed Formations:CLINTON-MEDINA, Issued Date:3/10/2010, Expired Date:3/10/2011 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2011-01-22 | RECONFIGURED UNIT LINES 1-3-17 MSE |
Construction Permit Expires | 2011-03-10 | RECONFIGURED UNIT LINES 1-3-17 MSE |
Completion Report Received | 2011-10-12 | RECONFIGURED UNIT LINES 1-3-17 MSE |
Record Last Modified | 2017-10-24 | RECONFIGURED UNIT LINES 1-3-17 MSE |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2011-12-29 | 5016 | 5096 | 27 |
5016 | 5096 | 27 | |
5016 | 5096 | 27 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2011-01-26 | H2O | 20 | 130491 Gal | 33000 | Universal Well Services Inc. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2011 | PAC DRILLING LLC | 13050.00 | 1587.00 | 319 |
2012 | PAC DRILLING LLC | 13168.00 | 737.00 | 361 |
2013 | PAC DRILLING LLC | 9845.00 | 522.00 | 365 |
2014 | PAC DRILLING LLC | 12202.00 | 359.00 | 360 |
2015 | PAC DRILLING LLC | 10384.00 | 291.00 | 360 |
2016 | PAC DRILLING LLC | 7772.00 | 252.00 | 359 |
2017 | PAC DRILLING LLC | 6503.00 | 159.00 | 359 |
2018 | PAC DRILLING LLC | 6328.00 | 142.00 | 359 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2011 | PAC DRILLING LLC | Brine | 50 | 319 |
2012 | PAC DRILLING LLC | Brine | 50 | 361 |
2013 | PAC DRILLING LLC | Brine | 0 | 365 |
2014 | PAC DRILLING LLC | Brine | 37 | 360 |
2015 | PAC DRILLING LLC | Brine | 36 | 360 |
2016 | PAC DRILLING LLC | Brine | 36 | 359 |
2017 | PAC DRILLING LLC | Brine | 28 | 359 |
2018 | PAC DRILLING LLC | Brine | 28 | 359 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1077589453 | 2019-11-18 0:00 | UP | No Violations | |
-1433838514 | 2020-9-4 0:00:0 | UP | No Violations | |
-1608798627 | 2020-5-14 0:00: | UP | No Violations | |
-1703218928 | 2018-5-11 0:00: | UP | No Violations | |
-1721995641 | 2016-2-12 0:00: | UP | No Violations | 0.50 |
-961814767 | 2011-9-27 0:00: | PL | No Violations | |
0135779843 | 2017-02-15 | UrbanProduction Wells | No Violations
--9---site inspection. PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9--e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9- 3) Repair the gas leak at the well. 4) Install a locked gate at the access road entrance and post the proper identification sign per 1501:9-9- The equipment on the pad consists of the following:
| |
0961814767 | 2011-09-27 | Preliminary Restoration | No Violations | Preliminary Restoration meets all requirements. |
1059092203 | 2019-02-25 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 1507725318. At the time of this inspection, no changes have occurred since my last inspection. The listed items below still need addressed in order for this site to regain compliance.
PAC needs to: 1) Install the barb wire at the top of the existing tank battery fencing. 2) The top of the production tanks extend more than 3 foot above the fence and needs modified as required by 1501:9-9-05E(4)(f). 3) The identification located at the tank battery still needs the required information added per 1501:9-9-05E(1)(a-e). 4) Landscaping at the tank battery still needs installed per 1501:9-9-05 E(6). |
135779843 | 2017-2-15 0:00: | UP | No Violations | 0.40 |
1360936482 | 2013-01-08 | UrbanProduction Wells | No Violations | I responded to a compliant from the Liberty Fire Department for the smell of natural gas. I was asked to investigate all of the wells along Loganway Avenue from Twin Oaks Drive to Route 80. I called Jason Caldwell at 330-340-6238. I instructed him to send their well tender, Rusty, out immediately to inspect all of the production equipment and the wellheads. Also, I told him to walk the sale and flow. My inspection found no leaks or spills and no natural gas smell. All of the production equipment was operating appropriately. Rusty walked the sale and flow line and found no leaks. A total of 6 wells were within the affected area; all belonging to PAC Drilling. The permit numbers for the other wells where 2-4014, 2-4013, 2-4012, 2-3882. I spoke to the Cathy Macchione at the Fire Department and told her of my finding. |
1507725318 | 2017-10-11 | UrbanProduction Wells | Violations Noted
--9-05(E)(1)(a- PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 3) Install urban safety equipment on the production tank as required by 1501:9-9-05(E)(4)(b-e): Activated charcoal filters. Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor. 5) Place landscaping on the north side of the tank battery as required by 1501:9-9-05(E)(6). | |
1555326659 | 2018-07-16 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 1507725318. At the time of this inspection, the production tank was still missing the required urban safety equipment per 1501:9-9--e). The chain link fence around the tank battery still needs barb wire added. The top of the production tanks extend more than 3 foot above the fence and needs modified as required by 1501:9-9--9--e). There was no landscaping at the tank battery. |
1703218928 | 2018-05-11 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 1507725318. The well was equipped with a plunger lift assembly, and the annulus and flow line valves were open. There was an identification sign posted on the white plastic fence surrounding the well. The diked tank battery has two storage tanks and a separator. The pick-up lines are secure with the valve handles removed and plugs. The production tank was missing the required urban safety equipment, and needs installed as required by 1501:9-9--e). A locked chain link fence with barb wire surrounds the tank battery. The top of the production tanks extend more than 3 foot above the fence and needs modified as required by 1501:9-9--9--e). There was no landscaping at the tank battery. The tank battery was approximately 80 feet from Loganway Wick Ave. The access road was stable. |
1721995641 | 2016-02-12 | UrbanProduction Wells | No Violations | I was on location in reference to compliance notice #-1641241853. During my inspection, I found a lock installed on the fence gate at the well head per my request. |
1726064901 | 2019-7-2 0:00:0 | UP | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1507725318 | US-OH-114235 | 2017-12-26 | ID (a-i) | |
1507725318 | US-OH-114236 | 2017-12-26 | FENCING (a-d) | |
1507725318 | US-OH-114237 | 2017-12-26 | TANKS (a-i) | |
1507725318 | US-OH-114238 | 2017-12-26 | LANDSCAPING (a-c) |