X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-24035

Well Details

Well ID: 34-155-24035
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hubbard Township
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: ALBRIGHT
License Status: Producing
License Date: 2011-01-03
Spud Date: 2011-01-09
Spud Drilling Contractor: G & H DRLG
Final Drill Date: 2011-01-14
Well Total Depth: 5300.00 ft
Configuration: Vertical
Latitude: 41.190000
Longitude: -80.590000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-01-03 Proposed Formations:CLINTON/MEDINA, Issued Date:1/3/2011, Expired Date:1/2/2013 12:00:00 PM, Drilling unit acres:41.26, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2011-01-14
Completion Report Received 2011-10-12
Construction Permit Expires 2012-01-03
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-12-29 4986 5064 50
4986 5064 50
4986 5064 50

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2011-01-19 H2O 20 136683 Gal 30000 Universal Well Services Inc.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 PAC DRILLING LLC 17768.00 781.00 328
2012 PAC DRILLING LLC 19750.00 566.00 361
2013 PAC DRILLING LLC 13642.00 394.00 365
2014 PAC DRILLING LLC 12684.00 342.00 360
2015 PAC DRILLING LLC 10757.00 193.00 358
2016 PAC DRILLING LLC 7789.00 267.00 359
2017 PAC DRILLING LLC 6602.00 206.00 359
2018 PAC DRILLING LLC 6331.00 169.00 359

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 PAC DRILLING LLC Brine 40 328
2012 PAC DRILLING LLC Brine 18 361
2013 PAC DRILLING LLC Brine 55 365
2014 PAC DRILLING LLC Brine 33 360
2015 PAC DRILLING LLC Brine 59 358
2016 PAC DRILLING LLC Brine 25 359
2017 PAC DRILLING LLC Brine 40 359
2018 PAC DRILLING LLC Brine 0 359

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1213405067 2016-6-30 0:00: UP No Violations 0.70
-1867015950 2017-10-10 0:00 UP No Violations 0.30
-265420290 2018-5-17 0:00: UP No Violations
0013402709 2012-06-27 UrbanProduction Wells No Violations On 6/27/2012, I completed an urban production well inspection status check. My inspection found the well was a plunger lift unit (rabbit) that was in good condition. The tank battery contained one 210 barrel oil storage tank, with the proper identification posted, one 50 barrel brine tank, and a separator. I noticed no visible spills or leaks. The lease road was in good condition, there are no violations at this time.
0265420290 2018-05-17 UrbanProduction Wells No Violations I conducted a compliance notice follow-up for compliance notice 1867015950. The well was equipped with a plunger lift assembly. The annulus and flow line valves were open. There was an identification posted at the well, but no fence has been installed around the well. The well was located approximately 700 feet from all private residences in a clearing surrounded by trees. The diked tank battery has two storage tanks and a separator. The pick-up lines have plugs, but no locks. The required urban safety equipment was missing from the production tank. A domestic gas supply was plumbed off of the sales line at the separator with an open ball valve, gas meter and field regulator. An identification sign was posted at the tank battery, but was missing the required information per 1501:9-9-05(E)(1)(a-e). Fencing around tank battery was not waived on the pre-site inspection; however, there are trees and vegetation on three sides of the tank battery, and not visible from Chestnut Ridge Road. The access road was stable, with no gate at the entrance. The gate was not waived during the pre-site inspection.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install fencing at the well and tank battery. Install a gate with the proper identification sign and lock at the access road entrance per 1501:9-9-05(E)(1)(a-f) & 1501:9-9-05(E)(2)(a-d) & 1501:9-9-05(E)(2)(c). 3) Install the required urban safety equipment on the production tank as required by 1501:9-9-05(E)(4)(b-e) Activated charcoal filters. Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor. 4) Install a locks on the pick-up lines or remove the valve handles as required by 1501:9-9-05(E)(3).

1213405067 2016-06-30 UrbanProduction Wells No Violations


Install a lock on the load line. Install the urban safety equipment

The equipment on the site consists of the following:


1 Mechanical separator 1 Production well

1325104412 2019-02-28 UrbanProduction Wells No Violations I conducted a compliance notice follow-up for compliance notice 1867015950. At the time of this inspection, the fence still needs installed around the well. The pick-up lines have plugs, but no locks on the production tanks within the tank battery. The required urban safety equipment was still missing the spark arrestor and pressure relief valve from the production tank. A charcoal filter has been installed on the 210 BBL production tank. An identification sign was posted at the tank battery, but needs amended with the required information per 1501:9-9-05(E)(1)(a-e). Fencing around tank battery was not waived on the pre-site inspection. No gate has been installed at the lease access entrance. The gate was not waived during the pre-site inspection.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install fencing at the well and tank battery. Install a gate with the proper identification sign and lock at the access road entrance per 1501:9-9-05(E)(1)(a-f) & 1501:9-9-05(E)(2)(a-d) & 1501:9-9-05(E)(2)(c). 3) Install the required urban safety equipment on the production tank as required by 1501:9-9-05(E)(4)(b-e) Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor. 4) Install a locks on the pick-up lines or remove the valve handles as required by 1501:9-9-05(E)(3).

13402709 2012-6-27 0:00: UP No Violations 0.50
1489683091 2017-03-07 UrbanProduction Wells No Violations

-up lines have plugs, but no locks. The required urban safety equipment is missing from the production tank. A domestic gas supply is plumbed off of the sales line at the separator with an open ball valve, gas meter and field regulator. An identification sign is posted at the tank battery. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a-e). Fencing around the well and tank battery was not waived on the pre-site inspection; however, there are trees and vegetation surrounding the tank battery. The access road is in good repair with no gate at the entrance. The gate was not waived during the pre-site inspection.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install a gate with the proper identification sign at the access road entrance per 1501:9-9-05(E)(1)(a-f) & 1501:9-9-05(E)(2)(c). 3) Install the required urban safety equipment on the production tank as required by 1501:9-9-05(E)(4)(b-e) Activated charcoal filters. Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor. 4) Install locks on the pick-up lines or remove the valve handles as required by 1501:9-9-05(E)(3).

The equipment on the pad consists of the following:



1730308610 2011-09-14 Preliminary Restoration No Violations Preliminary Restoration was acceptable.
1867015950 2017-10-10 UrbanProduction Wells Violations Noted

-up line is secure with a plug and the handle has been removed from the valve. The required urban safety equipment is missing from the production tank. A domestic gas supply is plumbed off of the sales line at the separator with an open ball valve, gas meter and field regulator. An identification sign is posted at the tank battery. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a-e). Fencing around tank battery was not waived on the pre-site inspection; however, there are trees and vegetation on three (3) sides of the tank battery. The tank battery is not visible from Chestnut Ridge Road. The access road is in good repair with no gate at the entrance. The gate was not waived during the pre-site inspection.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install a gate with the proper identification sign and lock at the access road entrance per 1501:9-9-05(E)(1)(a-f) & 1501:9-9-05(E)(2)(c). 3) Install the required urban safety equipment on the production tank as required by 1501:9-9-05(E)(4)(b-e) Activated charcoal filters. Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor. -up line or remove the valve handle as required by 1501:9-9-05(E)(3).

649841933 2019-8-15 0:00: UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1867015950 US-OH-118699 2017-12-26 ID (a-i)
1867015950 US-OH-118700 2017-12-26 LOCKS
1867015950 US-OH-118701 2017-12-26 TANKS (a-i)

For data sources see[9]

References