34-155-24036

Well Details

Well ID: 34-155-24036
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hubbard Township
Operator Name: PAC DRILLING LLC
Well Pad ID:
Farm/Lease Name: CHESTNUT RIDGE
License Status: Producing
License Date: 2011-01-06
Spud Date: 2011-01-25
Spud Drilling Contractor: G & H DRLG
Final Drill Date: 2011-01-29
Well Total Depth: 5240.00 ft
Configuration: Vertical
Latitude: 41.190000
Longitude: -80.580000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2011-01-06 Proposed Formations:CLINTON/MEDINA, Issued Date:1/6/2011, Expired Date:1/5/2013 12:00:00 PM, Drilling unit acres:56.89, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2011-01-29
Completion Report Received 2011-10-12
Construction Permit Expires 2012-01-06
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-12-29 4928 4988 48
4928 4988 48
4928 4988 48

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2011-02-02 H2O 20 140959 Gal 30000 Universal Well Services Inc.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 PAC DRILLING LLC 14742.00 555.00 293
2012 PAC DRILLING LLC 14300.00 418.00 362
2013 PAC DRILLING LLC 13183.00 299.00 365
2014 PAC DRILLING LLC 12371.00 172.00 360
2015 PAC DRILLING LLC 10567.00 183.00 361
2016 PAC DRILLING LLC 7769.00 163.00 359
2017 PAC DRILLING LLC 6603.00 132.00 359
2018 PAC DRILLING LLC 6343.00 129.00 359

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 PAC DRILLING LLC Brine 147 293
2012 PAC DRILLING LLC Brine 113 362
2013 PAC DRILLING LLC Brine 50 365
2014 PAC DRILLING LLC Brine 118 360
2015 PAC DRILLING LLC Brine 64 361
2016 PAC DRILLING LLC Brine 50 359
2017 PAC DRILLING LLC Brine 0 359
2018 PAC DRILLING LLC Brine 0 359

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1055652887 2020-4-24 0:00: UP No Violations
0309546681 2016-02-05 UrbanProduction Wells Violations Noted I was on location for a status check. During my inspection, I found the well in production. There is no identification posted at the tank battery. There are no locks on the load lines. There is no urban safety equipment. I called and spoke with PAC Drilling. I told PAC a compliance notice will be issued for no identification and no locks. Also, I instructed PAC to install the proper safety equipment. I told PAC a follow-up inspection would be completed by February 19, 2016.
0795463271 2018-05-17 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1507734792. At the time of this inspection, the well was equipped with a plunger lift assembly. The annulus and flow line valves were open. The well was fenced with a locked man door and had legible signage. The separator was located near the well and was fence with a lock. The tank battery has two storage tanks. The pick-up lines have plugs and the valve handles have been removed. The 210 BBL storage tank was missing the required urban safety equipment per 1501:9-9--e). The poly storage tank has a collapsed top. The two storage tanks are being held in place by steel cables, 4 inch steel posts and concrete blocks. There was a partial dike around the tank battery; however, the northwest corner of the dike wall has been washed away by the Little Yankee Run. The bend in the Little Yankee Run was approximately within 6 to 8 feet of the northwest corner of the tank battery. The identification sign at the tank battery was attached to the 210 BBL storage tank. The identification sign was missing the required information per 1501:9-9--e). There was no fencing around the tank battery. The fencing at the tank battery was not waived during the pre-site inspection. The tank battery was located approximately 57 feet from Drummond Avenue. No landscaping at the tank battery was present. The access roads to the well and tank battery are stable. The access road gate to the tank battery was not waived during the pre-site inspection. The access road to the well and separator is currently being used as a drive for the campground.
1024673898 2013-10-24 UrbanPreliminary Restoration No Violations My inspection found the well in production. The well was equipped with a plunger lift unit. The separator was in good condition. There were chain link fences surrounding the well and separator with no locks. The tank battery contained a 210 barrel production tank and a 50 barrel brine tank. Both tanks were anchored to concrete blocks. The dike met containment requirements. The proper identification signs were posted at the well and production tank. There was no safety equipment installed on the production tank. The site was graded and vegetation was well established. All debris was removed. Drainage and erosion controls were in place. The lease road was in good working condition. I called the well tender, Rusty, at 330-519-3761. I instructed Rusty to install locks on the fence gates at the well and separator. Also, I told Rusty that safety equipment needed to be installed on the production tank.
1131658118 2016-07-20 UrbanProduction Wells No Violations I was on location to assess compliance notice # 309546681. At the time of my inspection, I found an identification sign posted at the tank battery per my request. There is a lock on the load line.
1134179649 2011-10-31 Production Wells No Violations
1299157079 2011-02-10 Urban Drill / Deepen / Reopen No Violations Met with Justin Caldwell w/ Pac Drilling , Alex Kostra w/ Army Corp of Engineers and Ed Wilk w/ OEPA On wellsite area . We walked over wellsite and lease road areas . We then discussed possible wetlands impact where culverts were plased in lease road . Ed or Alex could not make a determination if wetlands had been affected or not . Ed advised me the Corp or OEPA Needed to be contacted if any stream was to be crossed before any construction occurred to determine possible wetland impact . NOTE: Verbal approval from Alex Kostra to place mud boat in main stream to Myself and Justin Caldwell if Justin applied for tempoary permit for stream crossing .
1305290941 2011-01-13 Drill / Deepen / Reopen No Violations On site for well construction .
1318603317 2011-10-14 UrbanPreliminary Restoration No Violations The 210 barrel and a poly tank were both anchored down. The dike walls need built-up. The well and tank battery need a fence.
1490015531 2017-03-09 UrbanProduction Wells No Violations

--9-05(E)(1)(a-e). There is no fencing around the tank battery. The fencing at the tank battery was not waived during the pre--site inspection. The access road to the well and separator is a drive for the campground. I spoke with Jeremy Caldwell from PAC Drilling concerning the dike and proximity of the tank battery to the Little Yankee R

1507734792 2017-10-11 UrbanProduction Wells Violations Noted I found the well in production on the day of my inspection. There are locked chain link fences around the well and separator. The dike around the tank battery is still washed out in the northwest corner next to Yankee Run River. There is no urban safety equipment on the production tank. The top of the poly storage tank is crushed in and needs replaced. An identification sign is posted; however, it does not meet the requirements of 1501:9-9--up lines are secure with plugs and the handles have been removed from the valves. There is no fencing around the tank battery. The fencing was not waived during the pre-site inspection.

PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9--e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install fencing around the tank battery as required by 1501:9-9--9- 3) Install urban safety equipment on the production tank as required by 1501:9-9--e): Activated charcoal filters. Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor. 4) Repair the dike around the tank battery per 1501:9-9-05(A)(9).

1913290113 2019-03-01 UrbanProduction Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1507734792, regarding multiple compliance issues related to urban rule requirements. At the time of this inspection, the 210 BBL storage tank was missing the spark arrestor and low pressure relief valve as required urban safety equipment per 1501:9-9-05E(4)(b-e). The poly storage tank has a collapsed top. The two storage tanks are being held in place by steel cables, 4 inch steel posts and concrete blocks. There was a partial dike around the tank battery; however, the northwest corner of the dike wall has been washed away by the Little Yankee Run. The bend in the Little Yankee Run was approximately within 6 to 8 feet of the northwest corner of the tank battery. The identification located at the tank battery was missing the required information per 1501:9-9-05E(1)(a-e). No fencing around the tank battery has been installed and the fencing was not waived during the pre-site inspection. The tank battery was located approximately 57 feet from Drummond Avenue. No landscaping at the tank battery was present. The access road gate to the tank battery was not waived during the pre-site inspection. The access road to the well and separator is currently being used as a drive for the campground.

PAC needs to: 1) Post an identification sign to be in compliance with 1501:9-9-05E(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install urban safety equipment on the production tank as required by 1501:9-9-05E(4)(b-e): Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor. 3) Place landscaping on the west and south sides of the tank battery as required by 1501:9-9-05E(6). 4) Install the required access gate with a lock at the access road entrance per 1501:9-9-05(E)(2)(c).

309546681 2016-2-5 0:00:0 UP No Violations 0.50
795463271 2018-5-17 0:00: UP No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0309546681 US-OH-123226 2016-08-04 ID (a-i)
0309546681 US-OH-123227 2016-08-04 LOCKS
1507734792 US-OH-114239 2017-12-26 ID (a-i)
1507734792 US-OH-114240 2017-12-26 FENCING (a-d)
1507734792 US-OH-114241 2017-12-26 TANKS (a-i)