If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-24047 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.17,"lon":-80.6,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Hubbard Township | |
Operator Name: PAC DRILLING LLC | |
Well Pad ID: | |
Farm/Lease Name: JOHNSON | |
License Status: Producing | |
License Date: 2011-09-30 | |
Spud Date: 2011-10-12 | |
Spud Drilling Contractor: G & L DRILLING | |
Final Drill Date: 2011-10-20 | |
Well Total Depth: 5310.00 ft | |
Configuration: Vertical | |
Latitude: 41.170000 | |
Longitude: -80.600000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2011-09-30 | Proposed Formations:CLINTON - MEDINA, Issued Date:9/30/2011, Expired Date:9/29/2013 12:00:00 PM, Drilling unit acres:41.68, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2011-10-20 | |
Completion Report Received | 2012-06-21 | |
Construction Permit Expires | 2012-09-29 | |
Record Last Modified | 2017-10-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2012-07-19 | 5028 | 5031 | 5 |
2012-07-19 | 5046 | 5062 | 16 |
5028 | 5031 | 5 | |
5046 | 5062 | 16 | |
5086 | 5100 | 15 | |
5028 | 5031 | 5 | |
2012-07-19 | 5086 | 5100 | 15 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 20 | 134700 Gal | 10000 | Universal Well Services Inc. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2011 | PAC DRILLING LLC | 2351.00 | 212.00 | 51 |
2012 | PAC DRILLING LLC | 23153.00 | 1414.00 | 362 |
2013 | PAC DRILLING LLC | 19268.00 | 856.00 | 365 |
2014 | PAC DRILLING LLC | 14101.00 | 567.00 | 360 |
2015 | PAC DRILLING LLC | 13791.00 | 533.00 | 360 |
2016 | PAC DRILLING LLC | 8191.00 | 374.00 | 359 |
2017 | PAC DRILLING LLC | 7346.00 | 374.00 | 359 |
2018 | PAC DRILLING LLC | 6526.00 | 357.00 | 359 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2011 | PAC DRILLING LLC | Brine | 50 | 51 |
2012 | PAC DRILLING LLC | Brine | 50 | 362 |
2013 | PAC DRILLING LLC | Brine | 0 | 365 |
2014 | PAC DRILLING LLC | Brine | 33 | 360 |
2015 | PAC DRILLING LLC | Brine | 0 | 360 |
2016 | PAC DRILLING LLC | Brine | 0 | 359 |
2017 | PAC DRILLING LLC | Brine | 0 | 359 |
2018 | PAC DRILLING LLC | Brine | 0 | 359 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1613269374 | 2019-2-4 0:00:0 | UP | No Violations | 0.40 |
-727947700 | 2011-10-21 0:00 | DD | No Violations | |
-813279622 | 2016-10-31 0:00 | UP | No Violations | 1.00 |
-821466082 | 2019-7-2 0:00:0 | UP | No Violations | |
0727947700 | 2011-10-21 | Drill / Deepen / Reopen | No Violations | The cementing of the production casing was witnessed. All conditions were acceptable. |
0813279622 | 2016-10-31 | UrbanProduction Wells | No Violations
On 12/13/2016, Northeast Regional Supervisor Tom Hill and I met with Justin Caldwell, co-owner of PAC Drilling, and Rusty Hornhill, well tender for PAC Drilling concerning the missing required urban safety equipment on 31 PAC Drilling wells in Hubbard and Liberty Townships. Mr. Caldwell has been given a document listing the wells with the missing the urban safety equipment. PAC Drilling is to submit a schedule for equipment installation for review and approval by the Division of Oil & Gas. | |
1323709010 | 2011-10-20 | Drill / Deepen / Reopen | Violations Noted | The edge of the pit liner fell into the pit. The driller and well owner (Jason Caldwell) were instructed to fix the pit liner immediately. |
1492098138 | 2017-04-10 | UrbanProduction Wells | No Violations
--up lines have plugs, but no locks. The 210 bbl. storage tank is missing the required urban safety equipment. A deduct meter and 31 day chart dated 29 March 2017 is installed at the separator. There is an identification sign posted at the tank battery. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a-e). There is a danger, keep out and no smoking sign(s) posted. The fencing around the tank battery was waived during the pre--site inspection. PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install a locks or remove the handles on the pick-up lines per 1501:9-9-05(E)(3). 3) Install urban safety equipment on the production tank as required by 1501:9-9-05(E)(4)(b-e): Activated charcoal filters. Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor. The equipment on the pad consists of the following:
| |
1528294734 | 2018-05-17 | UrbanProduction Wells | Violations Noted | At the time of this inspection, the well was equipped with a plunger lift assembly, and the annulus and flow line valves were open. There was identification posted at the well. A domestic gas supply comes off of the wellhead with an open 2 inch flow line ball valve, two regulators, a 4 inch drip tank and a gas meter. The fencing at the well was waived during the pre-site inspection. The diked tank battery has two storage tanks and a separator. The pick-up lines have plugs and the handles removed. The 210 BBL storage tank was missing the required urban safety equipment. There was an identification sign posted at the tank battery, and was missing the required information per 1501:9-9-05(E)(1)(a-e). The fencing around the tank battery was waived during the pre-site inspection. The access road was stable and shared with landowners driveway. The access road gate was waived during the pre-site inspection.
PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Install urban safety equipment on the production tank as required by 1501:9-9-05(E)(4)(b-e): Activated charcoal filters. Functioning low-pressure relief valve. Tank hatch lids shall have a functioning seal and the hatch shall be secured at all times. Functioning lightning arrestor. |
1613269374 | 2019-02-04 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 1528294734, involving the installation of urban safety equipment on the 210 BBL production tank. At the time of this inspection, The 210 BBL storage tank has had the spark arrestor installed but was still missing the required urban safety equipment, i.e. charcoal filter and pressure relief valve. There was an identification sign posted at the tank battery, and has been amended with the required information per 1501:9-9-05(E)(1)(a-e).
PAC needs to: 1) Install the urban safety equipment on the production tank as required per: 1501:9-9-05E(4)(b-e). |
394923051 | 2020-4-15 0:00: | UP | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1323709010 | US-OH-109261 | 2011-12-12 | Dike or pit not able to prevent escape of Brine or other wastes | |
1528294734 | US-OH-114636 | 2018-06-06 | 9-05E1 | ID (a-i) |
1528294734 | US-OH-114637 | 2018-06-06 | 9-05E4 | TANKS (a-i) |
For data sources see[9]