If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-24053 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.16,"lon":-80.59,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Hubbard Township | |
Operator Name: PAC DRILLING LLC | |
Well Pad ID: | |
Farm/Lease Name: VERDREAM | |
License Status: Producing | |
License Date: 2014-12-22 | |
Spud Date: 2015-01-14 | |
Spud Drilling Contractor: PEP DRLG | |
Final Drill Date: 2015-01-21 | |
Well Total Depth: 5320.00 ft | |
Configuration: Vertical | |
Latitude: 41.160000 | |
Longitude: -80.590000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2012-01-05 | Proposed Formations:CLINTON/MEDINA, Issued Date:1/5/2012, Expired Date:1/4/2014 12:00:00 PM, Drilling unit acres:42.97, Proposed Well Type:OG, Proposed Well Class:POOL |
APP | 2014-12-22 | Proposed Formations:CLINTON-MEDINA, Issued Date:12/22/2014, Expired Date:12/21/2016 12:00:00 PM, Drilling unit acres:42.97, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2015-01-21 | |
Completion Report Received | 2015-04-02 | |
Construction Permit Expires | 2016-12-21 | |
Record Last Modified | 2017-10-23 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2015-04-07 | 5023 | 5084 | 16 |
5023 | 5084 | 16 | |
5023 | 5084 | 16 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2015-01-30 | H2O | 0 | 3215 Bbl | 50200 | Universal Well Services Inc. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2015 | PAC DRILLING LLC | 9931.00 | 191.00 | 360 |
2016 | PAC DRILLING LLC | 8431.00 | 254.00 | 359 |
2017 | PAC DRILLING LLC | 6513.00 | 166.00 | 359 |
2018 | PAC DRILLING LLC | 6260.00 | 172.00 | 359 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2015 | PAC DRILLING LLC | Brine | 44 | 360 |
2016 | PAC DRILLING LLC | Brine | 108 | 359 |
2017 | PAC DRILLING LLC | Brine | 30 | 359 |
2018 | PAC DRILLING LLC | Brine | 0 | 359 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1200916639 | 2018-5-14 0:00: | UP | No Violations | |
-1472263034 | 2016-2-5 0:00:0 | UP | No Violations | 0.50 |
-2038793074 | 2017-3-17 0:00: | UP | No Violations | 0.70 |
-2073247158 | 2016-1-21 0:00: | UP | No Violations | 0.50 |
-2142566109 | 2015-1-15 0:00: | DD | No Violations | 7.50 |
-47240431 | 2016-5-20 0:00: | UP | No Violations | 0.70 |
-556786403 | 2016-3-29 0:00: | UP | No Violations | 1.00 |
-641174108 | 2020-3-27 0:00: | UP | No Violations | |
0047240431 | 2016-05-20 | UrbanProduction Wells | No Violations | I was on location reference to compliance notice #2107885667. At the time of my inspection, I found the chain link fence around the tank battery still has not been installed. |
0280243552 | 2016-03-07 | UrbanProduction Wells | No Violations | I was on location reference to compliance notice #2107885667. During my inspection, I found the fence around the tank battery has not been completed. There is a lock on the load line. I called and spoke with Gus Zoppi from PAC Drilling. Mr. Zoppi stated the fence should be up within a week. |
0347031095 | 2015-01-30 | Drill / Deepen / Reopen | No Violations | I was on location for a status check. During my inspection, I found Universal Well Service rigging up to stimulate the well for PAC Drilling. Universal placed 500 gallons of HCL acid into the well at 9:40am. Water temperature of the fresh water was 51 degrees. The top perforation was at 5, 023 from ground level (GL) and the bottom perforation was at 5,084 GL. I confirmed with PAC drilling and Universal that the 8.625 casing was open and continuously monitored. Also, KDA was on location to build the tank battery. A 210 barrel production tank and 50 barrel brine tank had been delivered to the site. |
0556786403 | 2016-03-29 | UrbanProduction Wells | No Violations | I was on location reference to compliance notice #2107885667. During my inspection, I found the fence around the tank battery has not been completed. I called PAC Drilling and instructed Gus Zoppi to install the fence around the tank battery. |
0696563873 | 2019-03-05 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up for compliance notice 1200916639, regarding multiple compliance issues related to urban rule requirements. At the time of this insspection, the top of the production tanks extend more than 3 foot above the fence and needs modified as required by 1501:9-9-05E(4)(f). The identification posted at the tank battery has the required information per 1501:9-9-05E(1)(a-e). No landscaping was installed around the tank battery, however the tank battery was located in a wooded area. The required access gate was not installed and was not waived during the pre-site inspection. Install the required gate with a lock at the access road entrance per 1501:9-9-05E(2), and post the proper identification sign on the access road gate per 1501:9-9-05E(1)(f).
|
0759838496 | 2016-07-12 | UrbanProduction Wells | No Violations | I was on location reference to compliance notice #2107885667. At the time of my inspection, I found the chain link fence around the tank battery installed. There is a lock and chain on the fence gate. The load line is secure with a bull plug and a lock. There are no further violations at this time. |
0900339356 | 2015-01-22 | Drill / Deepen / Reopen | No Violations | I was on location to pick-up the cement ticket for the production casing. PEP Drilling drilled a 7.875 Hole #3 to 5,307 GL and set 125 joints plus two pup joints of 4.5 production casing to 5,286 GL with 20 centralizers. Universal Well Service established circulation and pumped 200 sacks of Unitropic cement. The cement was displaced to 5,276 GL. |
1061992380 | 2016-02-12 | UrbanProduction Wells | No Violations | I was on location reference to compliance notice #2107885667. During my inspection, I found the fence around the tank battery not completed. There is a lock installed on the load line. |
1200916639 | 2018-05-14 | UrbanProduction Wells | Violations Noted | At the time of this inspection, the well was equipped with a plunger lift assembly. The annulus and flow line valves were open. There was an identification posted at the well, and the well fencing has been waived. The diked tank battery has two storage tanks and a separator. The pick-up lines are secure with the valve handles removed and plugs. The production tank had the required urban safety equipment. There was a locked chain link fence surrounding the tank battery. The top of the production tanks extend more than 3 foot above the fence and needs modified as required by 1501:9-9--9--e). No landscaping was installed around the tank battery, however the tank battery was located in a wooded area. The access was stable. The required access gate was not installed and was not waived during the pre-site inspection. Install the required gate with a lock at the access road entrance per 1501:9-9--9- |
1324413562 | 2015-02-18 | Drill / Deepen / Reopen | No Violations | I was on location for a status check. During my inspection, I found the pits solidified and closed. The flow line had been run from the well to the tank battery. The tank battery was complete. Urban safety equipment was installed on the load line. |
1421348531 | 2015-01-14 | Drill / Deepen / Reopen | No Violations | I was on location for a status check. During my inspection, I found PEP Drilling setting up the rig. The pits were dug and properly lined. The rig supervisor estimated to begin drilling late tonight (1/14/2015). |
1421870852 | 2015-01-16 | Drill / Deepen / Reopen | No Violations | |
1472263034 | 2016-02-05 | UrbanProduction Wells | No Violations | I was on location reference to compliance notice #2107885667. During my inspection, I found the fencing around the tank battery has not been completed. Locks have been installed on the load lines. Follow-up inspections will continue. |
1656523814 | 2016-06-30 | Production Wells | No Violations | I was on location reference to compliance notice #2107885667. At the time of my inspection, I found the chain link fence around the tank battery installed. There is no lock on the fence gate and load line. I spoke with Rusty Hornhill, PAC well tender, on location. I instructed Mr. Hornhill has one week to:
Install a chain and lock on the fence gate. Install a lock on the storage tank load line. |
2038793074 | 2017-03-17 | UrbanProduction Wells | No Violations
---up line has a lock. The 210 bbl. storage tank has the required urban safety equipment. There is an identification sign posted at the tank battery. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a--site inspection. PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 3) Install the require gate with a lock at the access road entrance per 1501:9-9-05(E)(2)(c). 4) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f). -up line per 1501:9-9-05(E)(3). 6) Place landscaping at the tank battery on the west end as required by 1501:9-9-05(E)(6). The equipment on the pad consists of the following:
| |
2073247158 | 2016-01-21 | UrbanProduction Wells | No Violations | I was on location in reference to compliance notice 2107885667. During my inspection, I found metal posts installed around the tank battery with no fencing. A lock has been installed on the load line. I spoke with Jason Caldwell, owner of PAC Drilling. Mr. Caldwell stated the fencing will be completed by February 5, 2016. A follow-up inspection will be conducted. |
2107885667 | 2015-09-16 | UrbanPreliminary Restoration | Violations Noted
| |
2142566109 | 2015-01-15 | Drill / Deepen / Reopen | No Violations
-flush and Uni- | |
280243552 | 2016-3-7 0:00:0 | UP | No Violations | 0.50 |
347031095 | 2015-1-30 0:00: | DD | No Violations | 2.50 |
696563873 | 2019-3-5 0:00:0 | UP | No Violations | |
759838496 | 2016-7-12 0:00: | UP | No Violations | 0.70 |
900339356 | 2015-1-22 0:00: | DD | No Violations | 1.00 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1200916639 | US-OH-105263 | 2018-05-25 | 9-05E1 | ID (a-i) |
1200916639 | US-OH-105264 | 2018-05-25 | 9-05E2 | FENCING (a-d) |
1200916639 | US-OH-105265 | 2018-05-25 | 9-05E4 | TANKS (a-i) |
1200916639 | US-OH-105266 | 2018-05-25 | 9-05E6 | LANDSCAPING (a-c) |
2107885667 | US-OH-121552 | 2016-08-04 | FENCING (a-d) | |
2107885667 | US-OH-121553 | 2016-08-04 | LOCKS |