{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.18,"lon":-80.56,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Hubbard Township | |
Operator Name: PAC DRILLING LLC | |
Well Pad ID: | |
Farm/Lease Name: H.C.N. | |
License Status: Producing | |
License Date: 2012-08-01 | |
Spud Date: 2012-08-07 | |
Spud Drilling Contractor: WILDCAT DRILLING | |
Final Drill Date: 2012-08-12 | |
Well Total Depth: 5394.00 ft | |
Configuration: Vertical | |
Latitude: 41.180000 | |
Longitude: -80.560000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2012-08-01 | Proposed Formations:ROSE RUN, Issued Date:8/1/2012, Expired Date:8/1/2014 12:00:00 PM, Drilling unit acres:48.75, Proposed Well Type:OG, Proposed Well Class:EDPW |
Correction to Well | 2012-08-02 | CORRECTION TO PROPOSED TOTAL DEPTH, PROPOSED GEOLOIGCAL FORMATION & CASING PROGRAM. |
Reached Total Depth | 2012-08-12 | |
Completion Report Received | 2013-03-06 | |
Construction Permit Expires | 2013-08-01 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2013-03-05 | 5094 | 5248 | 45 |
5094 | 5248 | 45 | |
5094 | 5248 | 45 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2012-08-17 | H2O | 20 | 3370 Bbl | 50200 | Universal Well Services Inc. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | PAC DRILLING LLC | 5682.00 | 188.00 | 114 |
2013 | PAC DRILLING LLC | 15645.00 | 433.00 | 365 |
2014 | PAC DRILLING LLC | 12449.00 | 202.00 | 360 |
2015 | PAC DRILLING LLC | 10654.00 | 91.00 | 360 |
2016 | PAC DRILLING LLC | 7693.00 | 174.00 | 359 |
2017 | PAC DRILLING LLC | 6414.00 | 115.00 | 359 |
2018 | PAC DRILLING LLC | 6411.00 | 162.00 | 359 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | PAC DRILLING LLC | Brine | 84 | 114 |
2013 | PAC DRILLING LLC | Brine | 52 | 365 |
2014 | PAC DRILLING LLC | Brine | 67 | 360 |
2015 | PAC DRILLING LLC | Brine | 49 | 360 |
2016 | PAC DRILLING LLC | Brine | 0 | 359 |
2017 | PAC DRILLING LLC | Brine | 61 | 359 |
2018 | PAC DRILLING LLC | Brine | 61 | 359 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1242149039 | 2012-8-16 0:00: | UP | No Violations | 0.50 |
-1867996371 | 2013-5-29 0:00: | UP | No Violations | 0.50 |
-783354296 | 2012-9-5 0:00:0 | UD | No Violations | 0.50 |
-808592354 | 2017-12-18 0:00 | UP | No Violations | 0.40 |
0085958188 | 2017-04-24 | UrbanProduction Wells | No Violations
-up lines have plugs, but no locks. The 210 bbl. storage tank has the required urban safety equipment. A locked chain link fence surrounds the tank battery. The access road is in good repair. The equipment on the pad consists of the following:
| |
0290012650 | 2018-05-17 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up for compliance notice 2112323029. The well was equipped with a plunger lift assembly. The annulus and flow line valves were open. The identification sign was posted at the well. There was a locked chain link fence at the well. There was a domestic gas supply plumbed off of the wellhead. The diked tank battery has two storage tanks and a separator. The pick-up lines have plugs, but still need locks. The 210 BBL storage tank has the required urban safety equipment. The identification sign was missing the required information per 1501:9-9-05(E)(1)(a-e). A locked chain link fence surrounds the tank battery. The production tank was 3 foot above the top of the fence. The access road was stable. There was no access road gate and it was not waived during the pre-site inspection. No landscaping has been installed at the well site location, and it was not waved during the pre-site inspection.
PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Place landscaping on the south side of the tank battery as required by 1501:9-9-05(E)(6). 3) Install the require gate with a lock at the access road entrance per 1501:9-9-05(E)(2)(c). 4) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f). 5) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 6) Install locks on all pick-up lines or remove the handles per 1501:9-9-05(E)(3). |
0447796796 | 2017-09-08 | UrbanProduction Wells | No Violations
-up lines have plugs, but no locks. The 210 bbl. storage tank has the required urban safety equipment. A locked chain link fence surrounds the tank battery. The access road is in good repair. I spoke with Rusty Thornhill to remove the handles from the pick-up line valves or add locks. | |
0496192369 | 2019-03-08 | UrbanProduction Wells | No Violations | I conducted a compliance notice follow-up for compliance notice 2112323029, regarding multiple compliance issues related to urban rule requirements. At the time of this inspection, the pick-up lines have plugs, but still need locks or the handles removed. The identification sign was missing the required information per 1501:9-9-05(E)(1)(a-e). A locked chain link fence surrounds the tank battery. The production tank was 3 foot above the top of the fence. No access road gate has been installed, and it was not waived during the pre-site inspection. No landscaping has been installed at the well site location, and it was not waved during the pre-site inspection.
PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Place landscaping on the south side of the tank battery as required by 1501:9-9-05(E)(6). 3) Install the require gate with a lock at the access road entrance per 1501:9-9-05(E)(2)(c). 4) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f). 5) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 6) Install locks on all pick-up lines or remove the handles per 1501:9-9-05(E)(3). |
0783354296 | 2012-09-05 | Urban Drill / Deepen / Reopen | No Violations | My inspection found the pits filled and closed. |
0808592354 | 2017-12-18 | UrbanProduction Wells | No Violations | I found the proper urban safety equipment installed on the production tank. PAC still needs to:
Place landscaping on the south side of the tank battery. Install the require gate with a lock at the access road entrance. Post the proper identification sign on the access road gate. Raise the fencing around the tank battery or use low profile tanks. Install locks on all pick-up lines or remove the handles. |
1242149039 | 2012-08-16 | UrbanProduction Wells | No Violations | On 8/16/2012, I witnessed the preforation of this well. P.A.C. Drilling used Appalachian Well Survey to perform the perforations. |
1344877747 | 2012-08-12 | Urban Drill / Deepen / Reopen | No Violations | On 8/12/12, I witnessed the cementing of the 4.5 production casing and the setting of the latch down plug. |
1345812841 | 2012-08-23 | Urban Drill / Deepen / Reopen | No Violations | On 8/23/2012, I inspection the progress of the site after drilling. My inspection found the pits still open. I received a call from Jason Caldwell of P.A.C. Drilling to inform me they will start closing the pits on 8/28/2012. |
1406213823 | 2014-06-26 | UrbanPreliminary Restoration | No Violations | I was on location to perform an urban preliminary restoration. I found during my inspection the well equipped with a plunger lift unit that was in production. The tank battery consisted of a 210 barrel production tank, a 50 barrel, poly brine tank and a separator. A dike surrounded the tank battery. Identification signs were posted a the well and tank battery. Locked, chain link fences surrounded the well and production equipment. The proper safety equipment was installed on the production tank. The site was graded. Vegetation was well established. Drainage and erosion controls were in place. All debris and drilling equipment was removed. The pits were closed. The lease road was in excellent condition. |
1834247282 | 2020-3-27 0:00: | UP | No Violations | |
1867996371 | 2013-05-29 | UrbanProduction Wells | No Violations | My inspection found the well in production. The well was equipped with a plunger lift unit and a domestic gas line. It was surrounded by a chain link fence with no lock. The tank battery contained one, 210 barrel production tank, one, 50 barrel brine tank, and a separator. It was surrounded by a chain link fence with no lock and a dike capable of meeting containment requirements. There was a plug on the load line. An identification sign was posted at the tank battery and wellhead. There was no safety equipment. The lease road was in good condition covered with crushed gravel. I called PAC Drilling at 330-874-3781. I told PAC to install the safety equipment and place locks at both fences. |
2112323029 | 2017-10-11 | UrbanProduction Wells | Violations Noted
-up lines have plugs, but no locks. The 210 bbl. storage tank has the required urban safety equipment. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a--site inspection. There is no landscaping and it was not waved during the pre-site inspection. PAC needs to: 1) Correct the identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Place landscaping on the south side of the tank battery as required by 1501:9-9-05(E)(6). 3) Install the require gate with a lock at the access road entrance per 1501:9-9-05(E)(2)(c). 4) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f). 5) Raise the fencing around the tank battery or use low profile tanks to be in compliance with 1501:9-9-05(E)(4)(f). 6) Install locks on all pick-up lines or remove the handles per 1501:9-9-05(E)(3). | |
290012650 | 2018-5-17 0:00: | UP | No Violations | |
447796796 | 2017-9-8 0:00:0 | UP | No Violations | 0.50 |
496192369 | 2019-3-8 0:00:0 | UP | No Violations | |
85958188 | 2017-4-24 0:00: | UP | No Violations | 0.60 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
2112323029 | US-OH-121601 | 2017-12-26 | ID (a-i) | |
2112323029 | US-OH-121602 | 2017-12-26 | FENCING (a-d) | |
2112323029 | US-OH-121603 | 2017-12-26 | LOCKS | |
2112323029 | US-OH-121604 | 2017-12-26 | LANDSCAPING (a-c) |