| Well ID: 34-155-24085 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.17,"lon":-80.61,"icon":""}]} |
| Country: United States | |
| State: Ohio | |
| County: Trumbull | |
| Municipality: Hubbard Township | |
| Operator Name: PAC DRILLING LLC | |
| Well Pad ID: | |
| Farm/Lease Name: PATTERSON | |
| License Status: Producing | |
| License Date: 2013-11-21 | |
| Spud Date: 2014-01-03 | |
| Spud Drilling Contractor: POULSON DRILLING | |
| Final Drill Date: 2014-01-12 | |
| Well Total Depth: 5154.00 ft | |
| Configuration: Vertical | |
| Latitude: 41.170000 | |
| Longitude: -80.610000 |
For data sources see[1]
| Well Status | Well Status Date | Comment |
|---|---|---|
| APP | 2013-11-13 | Proposed Formations:CLINTON THRU MEDINA, Issued Date:11/13/2013, Expired Date:11/13/2015 12:00:00 PM, Drilling unit acres:41.884, Proposed Well Type:OG, Proposed Well Class:POOL |
| APP | 2013-11-21 | Proposed Formations:CLINTON THRU MEDINA, Issued Date:11/21/2013, Expired Date:11/21/2015 12:00:00 PM, Drilling unit acres:41.884, Proposed Well Type:OG, Proposed Well Class:POOL |
| Reached Total Depth | 2014-01-12 | |
| Completion Report Received | 2014-04-16 | |
| Construction Permit Expires | 2014-11-21 | |
| Record Last Modified | 2017-02-15 |
For data sources see[2]
| Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
|---|---|---|---|
| 2014-04-21 | 5128 | 5190 | 85 |
| 5128 | 5190 | 85 | |
| 5128 | 5190 | 85 |
For data sources see[3]
| Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
|---|---|---|---|---|---|---|
| 2014-01-23 | H2O | 20 | 3260 Bbl | 50000 | Universal Well Services Inc. | |
| 2014-01-23 | ACID | 0 | 500 Gal | 50000 | Universal Well Services Inc. | On 1/23/2014, I witnessed Universal Well Service stimulate the Clinton Sandstone formation for PAC Drilling. The backside annulus was completely open during the stimulation operations with no failures. There were no casing failures. All of the stimulation equipment operated smoothly for Universal Well Service. |
For data sources see[4]
| Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 2014 | PAC DRILLING LLC | 13652.00 | 712.00 | 360 |
| 2015 | PAC DRILLING LLC | 11561.00 | 546.00 | 360 |
| 2016 | PAC DRILLING LLC | 7505.00 | 336.00 | 360 |
| 2017 | PAC DRILLING LLC | 6350.00 | 291.00 | 360 |
| 2018 | PAC DRILLING LLC | 5978.00 | 194.00 | 360 |
| Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
|---|---|---|---|---|
| 2014 | PAC DRILLING LLC | Brine | 116 | 360 |
| 2015 | PAC DRILLING LLC | Brine | 56 | 360 |
| 2016 | PAC DRILLING LLC | Brine | 24 | 360 |
| 2017 | PAC DRILLING LLC | Brine | 0 | 360 |
| 2018 | PAC DRILLING LLC | Brine | 0 | 360 |
| Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|
| -79522791 | 2018-5-15 0:00: | UP | No Violations | |
| -817809950 | 2017-10-11 0:00 | UP | No Violations | 0.40 |
| -877708453 | 2014-8-4 0:00:0 | UL | No Violations | 0.50 |
| 0079522791 | 2018-05-15 | UrbanProduction Wells | No Violations | I conducted an compliance notice follow-up inspection for compliance notice 817809950. The well was equipped with a plunger lift assembly and the annulus and flow line valves were open. There was still no identification posted at the well. No fencing surrounded the well; however, the fencing was waived during the pre-site inspection. The diked tank battery has three storage tanks and a separator. The pick-up lines are secure with handles removed from the valves and plugs. The 210 BBL storage tanks have the required urban safety equipment. There was an identification sign posted at the tank battery, but was missing the required information per 1501:9-9--e). The fencing around the tank battery was waived during the pre-site inspection. The access road was stable with two locked gates at the entrance and shared with permit #2-4084. Identification was needed on the gate.
PAC needs to: 1) Post an identification sign to be in compliance with 1501:9-9--e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 4) Post the proper identification sign on the access road gate per 1501:9-9- 3) Post an identification sign at the well per 1501:9-9- |
| 0817809950 | 2017-10-11 | UrbanProduction Wells | Violations Noted
--up lines are secure with plugs and the handles have been removed from the valves. The 210 bbl. storage tanks have the required urban safety equipment. There is an identification sign posted at the tank battery. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a-e). There is no danger, keep out and no smoking sign(s) posted. The fencing around the tank battery was waived during the pre--4084. There is no identification sign on the gate. PAC needs to: 1) Post an identification sign to be in compliance with 1501:9-9-05(E)(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 4) Post the proper identification sign on the access road gate per 1501:9-9-05(E)(1)(f). 3) Post an identification sign at the well per 1501:9-9-05(E)(2). | |
| 0877708453 | 2014-08-04 | UrbanPreliminary Restoration | No Violations | I was on location for an urban preliminary restoration. I found during my inspection the well site graded. The site was well vegetated. The pits were filled and closed. All debris was removed. Erosion and drainage controls are in place. The well was in production with a plunger lift unit. The tank battery consisted of two, 210 barrel production tanks, a 50 barrel brine tank and a separator. A dike surrounded the production equipment. The production equipment had the correct spacing. The proper identification was posted. The proper urban safety equipment was installed on both production tanks. Plugs were installed on the load lines. The lease road was in good condition. The tank battery was located in an isolated and wooded area; fencing was waived on the pre-site inspection. Urban preliminary restoration passed. |
| 0914753905 | 2014-01-06 | Drill / Deepen / Reopen | No Violations | I witnessed Universal Well Service cement the surface casing for PAC Drilling. Poulson Drilling drilled a 11 Hole #2 to 750 GL (ground level) and set 8.625 casing to 718 GL with two centralizers. The casing was 23 lbs. The bottom of the Berea Sandstone was logged at 612. Universal established circulation with 12 bbls of fresh water followed by 500 gallons of Uniflush. Next, the operator pumped 150 sacks of Unifill Lite as the lead cement followed by 125 sacks of Type 1 as the tail cement. The cement was displaced to 703 GL with 45 bbls of fresh waster. I witnessed 23 bbls of good cement returned to surface. Cement was static at surface within the casing annulus after 20 minutes. |
| 1387222099 | 2013-12-16 | Drill / Deepen / Reopen | No Violations | My inspection found Kleese Development building the well site and lease road. Drainage and erosion controls were being installed. No violations at this time. |
| 1389102384 | 2014-01-04 | Drill / Deepen / Reopen | No Violations | I witnessed Universal Well Service cement the conductor for PAC Drilling. Poulson Drilling drilled a 14.75 Hole #1 to 70 GL (ground level) and set 11.75 casing to 60 GL. The casing was 23 lb. Universal established circulation and pumped 20 bbls of gel. Next, Universal pumped 100 sacks of Type 1 cement. The cement was displaced to 40 with 6 bbls of fresh water. I witnessed 7 bbls of good cement returned to surface. After 20 minutes, the cement was static at surface. |
| 1395532767 | 2019-03-01 | UrbanProduction Wells | No Violations | I conducted an compliance notice follow-up inspection for compliance notice 817809950, regarding multiple compliance issues related to urban rule requirements. At the time of this inspection, identification still needed to be posted at the well. There was an identification sign posted at the tank battery, but was still missing the required information per 1501:9-9-05E(1)(a-e). The lease road gates were not locked, at the time of this inspection and the identification still has not been installed on the gate.
PAC needs to: 1) Post an identification sign to be in compliance with 1501:9-9-05E(1)(a-e) at the tank battery with: Well owners address and phone number Property street address or nearest address to the access road entrance. 2) Post the proper identification sign on the access road gate per 1501:9-9-05E(1)(f). 3) Post an identification sign at the well per 1501:9-9-05E(2). 4) Install the locks on both access gates. |
| 1490789442 | 2017-03-21 | UrbanProduction Wells | No Violations
--up lines have plugs, but no locks. The 210 bbl. storage tanks have the required urban safety equipment. A deduct meter and 31 day chart dated 1 March 2017 is installed at the separator. There is an identification sign posted at the tank battery. The identification sign is missing the required information per 1501:9-9-05(E)(1)(a-e). There is no danger, keep out and no smoking sign(s) posted. The fencing around the tank battery was waived during the pre--4084. There is no lock or identification sign on the gate. The equipment on the pad consists of the following:
| |
| 1965824593 | 2020-4-15 0:00: | UP | No Violations | |
| 914753905 | 2014-1-6 0:00:0 | DD | No Violations | 4.50 |
| Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
|---|---|---|---|---|
| 0817809950 | US-OH-129312 | 2017-12-26 | ID (a-i) |