{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.24,"lon":-80.58,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Brookfield Township | |
Operator Name: HIGHLAND FIELD SERVICES LLC | |
Well Pad ID: | |
Farm/Lease Name: HIGHLAND BROOKFIELD (SWIW #37) | |
License Status: Active Injection | |
License Date: 2017-06-21 | |
Spud Date: 2018-04-11 | |
Spud Drilling Contractor: FALCON DRLG | |
Final Drill Date: 2018-06-19 | |
Well Total Depth: 8480.00 ft | |
Configuration: Vertical | |
Latitude: 41.240000 | |
Longitude: -80.580000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2017-06-21 | Proposed Formations:KNOX THRU ROME, Issued Date:6/21/2017, Expired Date:6/19/2018, Drilling unit acres:0, Proposed Well Type:SWD, Proposed Well Class:SWIW |
Reached Total Depth | 2018-06-19 | AUTHORIZATION TO INJECT GRANTED 10/22/2018 |
Construction Permit Expires | 2018-06-21 | AUTHORIZATION TO INJECT GRANTED 10/22/2018 |
Last Compliance Report | 2018-10-24 | AUTHORIZATION TO INJECT GRANTED 10/22/2018 |
Record Last Modified | 2018-10-24 | AUTHORIZATION TO INJECT GRANTED 10/22/2018 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2018-10-24 | 7589 | 8480 | 0 |
7589 | 8480 | 0 | |
7589 | 8480 | 0 |
For data sources see[3]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1073952577 | 2018-7-2 0:00:0 | DD | No Violations | 1.30 |
-1101723191 | 2018-11-15 0:00 | SW | No Violations | 1.50 |
-11619439 | 2018-5-24 0:00: | DD | No Violations | 1.30 |
-1177351489 | 2018-7-11 0:00: | DD | No Violations | |
-1193747376 | 2020-3-5 0:00:0 | SW | No Violations | |
-1248548378 | 2018-12-27 0:00 | SW | No Violations | 0.30 |
-1265404814 | 2017-11-17 0:00 | SW | No Violations | 1.00 |
-1314985551 | 2020-4-20 0:00: | SW | No Violations | 0.60 |
-1362240278 | 2018-8-15 0:00: | SW | No Violations | 1.20 |
-1405551473 | 2019-2-19 0:00: | SW | No Violations | 0.40 |
-1419747730 | 2018-10-30 0:00 | SW | No Violations | 0.50 |
-1430523634 | 2018-7-23 0:00: | DD | No Violations | 2.30 |
-1503624929 | 2018-2-28 0:00: | ND | No Violations | 0.80 |
-1591194038 | 2018-6-11 0:00: | DD | No Violations | 1.50 |
-1635634908 | 2019-5-6 0:00:0 | SW | No Violations | 0.50 |
-1659199742 | 2018-1-11 0:00: | SW | No Violations | 0.20 |
-1680391646 | 2019-6-6 0:00:0 | SW | No Violations | 1.00 |
-179819436 | 2018-7-5 0:00:0 | DD | No Violations | 1.50 |
-1901588304 | 2019-7-31 0:00: | SW | No Violations | 0.80 |
-2015423586 | 2019-2-11 0:00: | SW | No Violations | 0.30 |
-2116097950 | 2019-1-7 0:00:0 | SW | No Violations | 1.50 |
-43642608 | 2018-6-7 0:00:0 | DD | No Violations | 2.50 |
-488481407 | 2018-8-27 0:00: | SW | No Violations | 1.30 |
-505314882 | 2019-2-28 0:00: | SW | No Violations | 1.50 |
-561676346 | 2018-11-19 0:00 | SW | No Violations | 1.50 |
-638796763 | 2018-4-12 0:00: | CS | No Violations | |
-678014034 | 2018-6-13 0:00: | DD | No Violations | 2.80 |
-841951711 | 2019-1-10 0:00: | SW | No Violations | 0.40 |
0011619439 | 2018-05-24 | Drill / Deepen / Reopen | No Violations | |
0043642608 | 2018-06-07 | Drill / Deepen / Reopen | No Violations | |
0110198830 | 2019-03-04 | Salt Water Injection Well | No Violations | I found the CC Forbes rig has completed milling out the well and was tripping out. |
0179819436 | 2018-07-05 | Drill / Deepen / Reopen | No Violations | I found Keystone Clearwater Solutions still on site working on the secondary containment for frac tanks to be used for testing the well. |
0209640194 | 2018-08-03 | Salt Water Injection Well | No Violations | I found M & B Services on location constructing the forms and rebar in preparation for cementing the Off-Loading pads. GOH was on location performing dirt work for installing the fencing that will surround the well pad. |
0287105872 | 2018-02-16 | Salt Water Injection Well | No Violations | I found Glenn O. Hawbaker (GOH) spreading stone on the access road. Four (4) dump trucks full of stone arrived on location during my inspection. There are no violations at this time. |
0310235793 | 2019-01-02 | Salt Water Injection Well | No Violations | I was on location to assess a claim concerning a loud sound/explosion coming from the facility. According to the facility operators, the loud sound/explosion came from a landowner operating firearms south of the facility. Also, facility operators stated the Brookfield Police Department arrived on location between 4:00 pm and 4:30 pm on December 31, 2018 to investigate the loud sound. I found no evidence showing damage resulting from a loud sound/explosion. The facility and injection well are in good repair. I observed no leaks or spills in or around the facility and injection well. The injection well was in operation during my inspection. Glenn O. Hawbaker (GOH) was on location working on the well pads for the Highland #3 and #4. Two (2) Beimel brine trucks (#25-436) and a Rock Run brine truck (#25-665) arrived on location with the proper UIC number, brine, and company information displayed. There are no violations at this time. |
0398990959 | 2018-03-28 | Salt Water Injection Well | No Violations | I found Glenn O. Hawbaker (GOH) on site working on the access road and the well pad for the Highland #5. |
0399457442 | 2018-11-08 | Salt Water Injection Well | No Violations | I found the facility operator on location waiting on brine water deliveries. According to the facility operator, the tentative date to start injecting is November 19th. |
0473191958 | 2018-05-18 | Drill / Deepen / Reopen | No Violations | I found Falcon Drilling moving the rig and equipment onto location. There are no violations at this time. |
0488481407 | 2018-08-27 | Salt Water Injection Well | No Violations | I found Seneca Resources/Highland working of the construction of the temporary facility. I reviewed the blueprint for temporary facility and noticed a difference in the layout of the storage tanks. Next, I spoke with Terry Dunmyre from Seneca Resources on location. According to Mr. Dunmyre, the location of the storage tanks and equipment have been rearranged from the blueprint to make laying out the flow lines more efficient. Mr. Dunmyre stated the actual flow direction of the fluid from the off-loading pad to the injection well has not been changed. All of the storage tanks are on location except for a 400 bbl. Also, a crew was on location installing a chain link fence around the entire facility. |
0505314882 | 2019-02-28 | Salt Water Injection Well | No Violations | |
0561676346 | 2018-11-19 | Salt Water Injection Well | No Violations | I found the injection well not in operation on the day of my inspection. Seneca reps were on location for a final walk through of the injection well and temporary facility. I observed no leaks or spills. Identification signs are posted. |
0638796763 | 2018-04-12 | Casing String Witnessed | No Violations | HAD Drilling Rig # 247 was the drilling contractor for Highland Field Services. A 30 casing was concentrically drilled to 37 GL. Bedrock was reported encountered at 10 by HAD Drilling personnel. A 28 borehole was drilled with an air hammer to 83 GL on misted air. A fresh water flow estimated to be approximately 30 gals. / hr. was encountered in this section of the borehole. After the hole was drilled to total depth HAD lowered four joints of 24, 157 lbs. / ft., welded casing open ended into the hole. Circulation windows were cut into the casing 24 from the bottom of the casing. Three (3) bow spring centralizers were welded to the casing at 20, 40 and 60 depths. Petroset Cementing Services (PSC) connected to the casing and circulated 10 barrels of fresh water. The cement mix water was heated to 55 F, pH was 7 and Chlorides were < 250 ppm. The cement load was Class A with a mix yield of 1.18 cu.ft./sk. PCS mixed the cement slurry and displaced it with 38 barrels of water. Cement returns were observed at 30 barrels into displacement. I verified, by scale, cement slurry density at 15.1 ppg and 15.0 ppg. Circulation was observed throughout the entire job. Approximately eight (8) barrels of cement slurry were observed to return to the cellar. Plug was down at 1800 hrs. After twenty minutes , I observed that the cement level had fallen and could not be seen. I request from Gus ( Co-man ) that the cement top be measured after WOC time and topped off even with the 30 drive pipe. |
0678014034 | 2018-06-13 | Drill / Deepen / Reopen | No Violations | I found Falcon Rig 26 running drill pipe into the borehole to resume drilling. There are no violations at this time. |
0794753008 | 2017-11-27 | Salt Water Injection Well | No Violations | |
0841951711 | 2019-01-10 | Salt Water Injection Well | No Violations | I found the injection well in operation. There was a facility operator on location. I observed no leaks or spills. Identification is posted. |
0918225664 | 2018-06-04 | Salt Water Injection Well | No Violations | Falcon Drilling was air drilling at 6123. I inspected the air package, cellar and solids handling areas and did not identify any violations. I spoke with Don Creager ( Co-man) to remind him of the point at which it was required to switch to fluid drilling. |
0950224719 | 2018-08-08 | Salt Water Injection Well | No Violations | I found M & B Services working on the second off-loading concrete pad. Supplies and equipment was being delivered for constructing the temporary facility. |
1073952577 | 2018-07-02 | Drill / Deepen / Reopen | No Violations | I found Keystone Clearwater Solutions on site building a secondary containment for frac tanks to be used for testing the well. Falcon Rig 26 has completely moved off location. |
1101723191 | 2018-11-15 | Salt Water Injection Well | No Violations | I found Seneca reps and the facility manager running final maintenance checks on the electronic controls and pumps. The gate valves on the injection well and injection tubing are open. According to the facility manager, Highland only plans to pump enough fluid today to purge all of the air out of the system (up to 200 bbl.). I observed no spills or leaks within the diked tank battery. Identification signs are posted. |
110198830 | 2019-3-4 0:00:0 | SW | No Violations | 4.50 |
1118870146 | 2018-08-13 | Salt Water Injection Well | No Violations | I found M & B Services working on the Off-loading pads. The temporary steel dike is being installed. There are no violations at this time. |
1177351489 | 2018-07-11 | Drill / Deepen / Reopen | No Violations | I was on location to witness the tracer test. Haliburton was contracted to perform the tracer test and Formation Cementers supplied the pump truck. |
1248548378 | 2018-12-27 | Salt Water Injection Well | No Violations | I found the injection well in operation on the day of my inspection. I observed no leaks or spills in or around the injection well and facility. There were two (2) Beimel brine truck on location with the proper UIC number displayed (#25-436). Identification signs are posted. The digital display at the facility read 1407.0 psi for the injection tubing and 152.7 psi for the annulus. There are no violations at this time. |
1253402878 | 2018-12-18 | Salt Water Injection Well | No Violations | I found the injection well in operation on the day of my inspection. Identification signs are posted. There were seven (7) Beimel Transportation brine trucks on location with the proper UIC number, brine, and company information displayed (#25-436). I observed no spills or leaks. |
1265404814 | 2017-11-17 | Salt Water Injection Well | No Violations | |
1303810325 | 2020-7-8 0:00:0 | SW | No Violations | 1.00 |
1362240278 | 2018-08-15 | Salt Water Injection Well | No Violations | I found PAC has 13 vac boxes on location resting on the two (2) concrete slabs and off-loading area. PAC is still cleaning the 400 bbl. storage tank. According to the facility operator, one (1) or more of the vac boxes will be removed today. |
1405551473 | 2019-02-19 | Salt Water Injection Well | No Violations | I found SRE placing matting down on the well pad. The injection well is currently shut-in for maintenance. |
1419747730 | 2018-10-30 | Salt Water Injection Well | No Violations | I found injection well shut- |
1430523634 | 2018-07-23 | Drill / Deepen / Reopen | No Violations | |
1503624929 | 2018-02-28 | Not Drilled | No Violations
- | |
1512398085 | 2017-12-04 | Salt Water Injection Well | No Violations | I found Glenn O. Hawbaker (GOH) working on the access road. There are no violations at this time. |
1513608889 | 2017-12-18 | Salt Water Injection Well | No Violations | I found Glenn O. Hawbaker (GOH) working on the access road. There are no violations at this time. |
1515079989 | 2018-01-04 | Salt Water Injection Well | No Violations | |
1520538718 | 2018-03-07 | Not Drilled | No Violations | |
1521469083 | 2018-03-19 | Not Drilled | No Violations | I found Glenn O. Hawbaker (GOH) on site working on the access road and the well pad for the Highland #1. I spoke with Bill Johnson, GOH General Superintendent, and Mike Beers, GOH Site Foreman. Mr. Johnson stated GOH has a projected completion date of April 4, 2018 for the access road and the well pad for the Highland #5. |
1523989672 | 2018-04-17 | Salt Water Injection Well | No Violations | Access to the drilling pad was on a graveled road. HAD Drilling Rig # 247 was demobilized and parked on the pad. The cellar contained water which only allowed approximately three (3) feet of 24 casing visible. I did not see any evidence of gas migration in the cellar. Superior Energy Resources was on location laying down and sealing the containment cloth prior to positioning the rig mats. Subsequent to displacing the cement slurry ( 4/12/2018) the cement level fell down the annular space between the 30 drive pipe and 24 conductor casing and was measured at 28 from the top. Brian Bauer ( Highland Field Services ) said, that the casing was topped off with Sakrete level within the 30 casing stub. The water level in the cellar prevented me from confirming. Mr. Bauer anticipated mobilization of the second HAD Drilling rig around 5/1/2018. No violation identified during this inspection. |
1524580283 | 2018-04-23 | Drill / Deepen / Reopen | No Violations | I found Glenn O. Hawbaker (GOH) on site moving dirt for the UIC facility. |
1525270340 | 2018-05-02 | Drill / Deepen / Reopen | No Violations | I found HAD Drilling staging the rig and equipment onto the well pad. Glenn O. Hawbaker (GOH) is still working on the facility location. |
1525701955 | 2018-05-07 | Drill / Deepen / Reopen | No Violations | I found HAD Drilling rigging down from the well location. I spoke with Justin Green from Seneca. Mr. Green stated the contract between Seneca and HAD Drilling had been terminated. Mr. Green stated Falcon Drilling will be moving onto location around May 21, 2018. The access road is in good repair. Glenn O. Hawbaker (GOH) is still working on pad for the temporary facility. There are no violations at this time. |
1527087076 | 2018-05-23 | Drill / Deepen / Reopen | No Violations | |
1529595427 | 2018-06-21 | Drill / Deepen / Reopen | No Violations | |
1531312758 | 2018-07-10 | Drill / Deepen / Reopen | No Violations | I was on location to witness Highland acid treat the well. Haliburton was contracted to pump the acid. Haliburton pump 1,000 gallons (23.8 bbl.) of 15% acid to the bottom of the well and shut-in with a wellhead pressure reading of 1,297 psi. After 30 minutes, the wellhead pressure dropped to 1,082 psi. Next, Haliburton pumped 165,773 gallons (3,946.9 bbl.) of 10 lb. brine reaching a rate of 50 bbl/min. I observed no leaks or spills from the wellhead. |
1531916117 | 2018-07-17 | Drill / Deepen / Reopen | No Violations | I was on location to witness the setting of the packer and permit a mechanical integrity test (MIT). Excel Site Rental was the contracted rig (#832) and Formation Cementing supplied the pump truck. Halliburton supplied a Versa-Set Retrievable Packer (V--in at 5:00 pm. After 15 minutes, the pressure gauge had a reading of 2,160 psi. I observed no leaks. The MIT passed. Pressure on the annulus was dropped to 600 psi. |
1532705967 | 2018-07-27 | Salt Water Injection Well | No Violations | I found Glenn O. Hawbaker (GOH) performing dirt work for the proposed temporary facility and off-loading pad. |
1533562489 | 2018-08-06 | Salt Water Injection Well | No Violations | I found M & B Services pouring concrete for the Off-loading pads. The injection well is in good condition and shut-in while the temporary facility is being constructed. |
1534343004 | 2018-08-15 | Salt Water Injection Well | No Violations | I found M & B Services pouring concrete on the last section for the off-loading pads. The injection well is currently shut-in while the temporary facility is under construction. The well pad and access road are stable and in good repair. I observed Rt. 7 at the entrance of the access road clean and free of all debris. |
1536242062 | 2018-09-05 | Salt Water Injection Well | No Violations | I found Seneca Resources/Highland still working of the construction of the temporary facility. A chain link fence with barb wire has been installed around the facility area and well pad |
1539786357 | 2018-10-09 | Salt Water Injection Well | No Violations
There was zero drop in pressure during the test; passed. | |
1543334384 | 2018-11-27 | Salt Water Injection Well | No Violations | I found the injection well in operation on the day of my inspection. A facility operator was on location. The digital display read Highland was injecting at 755 psi and the pressure on the annulus was 139 psi. Highland is pumping at a rate of 1.4 BPM. I observed no leaks or spills. While on location, three (3) Beimel Transportation brine trucks arrived on location with the proper UIC number displayed (#25-436). An identification sign is posted on the fencing. |
1543932991 | 2018-12-04 | Salt Water Injection Well | No Violations | I received a call from Marisa Dollinger from Seneca/Highland at 6:29 am concerning a pump failure at the Highland #5 facility with approximately 1 bbl. of brine spilled inside of the containment dike. Ms. Dollinger stated the injection well has been shut-in until repairs are completed. Upon arrival, I found the injection well shut-in. The source of the brine spill was a failed flange gasket from the CoorsTek Stabilizer Cartridge installed on the injection line right after the injection pump located in the diked tank battery. The brine spill was already cleaned up. The brine spill was contained to inside of the dike. I spoke with the facility operator on location. Seneca was in process of obtaining a new gasket. The injection well will remain shut-in until repairs are completed. A follow-up inspection will be conducted. |
1544031845 | 2018-12-05 | Salt Water Injection Well | No Violations | I found Seneca has replaced the gasket on the CoorsTek Stabilizer Cartridge. The injection well was in operation. According to the digital display, the injection well was 1,135 psi and the annulus was 141 psi. There were facility operators on location. I observed no leaks or spills. |
1546277883 | 2018-12-31 | Salt Water Injection Well | No Violations | I was on location due to receiving a call from Marissa Dollinger from Seneca/Highland on 12/28/2018 concerning an issue with the CoorsTek Stabilizer Cartridge on the injection line located inside of the diked tank battery. Ms. Dollinger stated there was a break in the weld; however, there was no brine spill. Upon arrival, I found Seneca/Highland has repaired the CoorsTek Stabilizer Cartridge and installed additional bracing. I observed no evidence to spills or leaks inside of the tank battery. There was a Beimel brine truck off-loading on location with the proper identification on the trailer (#25-436). Two (2) Beimel brine trucks arrived on location with the proper identification. |
1551192996 | 2019-02-25 | Salt Water Injection Well | No Violations | |
1551292139 | 2019-02-27 | Salt Water Injection Well | No Violations
-in temporarily due to the main hydraulic pump stopped working. CC Forbes will resume tripping into the well once the new hydraulic pump arrives. | |
1551886086 | 2019-03-06 | Salt Water Injection Well | No Violations | I found the CC Forbes rigging down and moving equipment off site. The injection well is shut- |
1577198086 | 2019-12-24 0:00 | SW | No Violations | |
1578327696 | 2020-1-6 0:00:0 | SW | No Violations | 2.00 |
1591194038 | 2018-06-11 | Drill / Deepen / Reopen | No Violations | |
1630450032 | 2019-03-15 | Salt Water Injection Well | No Violations | I found the injection well shut-in. The injection line is disconnected from the injection well. There are no spills or leaks. |
1633928080 | 2018-09-26 | Salt Water Injection Well | No Violations | I found Seneca Resources/Highland still working of the construction of the temporary facility. The plumbing and electrical were being connected. The chain link fencing around the facility and well has been completed. The injection line from the facility to the injection well has not been ran at this time. |
165032842 | 2019-8-29 0:00: | SW | No Violations | 0.50 |
1659199742 | 2018-01-11 | Salt Water Injection Well | No Violations | I found Glenn O. Hawbaker (GOH) working on the access road. There are no violations at this time. |
1695693804 | 2019-01-16 | Salt Water Injection Well | No Violations | I found the injection well not operating during my inspection. I observed no leaks or spills. Identification signs are posted. |
1799333988 | 2019-4-24 0:00: | SW | No Violations | 0.30 |
1953842728 | 2018-06-20 | Drill / Deepen / Reopen | No Violations | |
2015423586 | 2019-02-11 | Salt Water Injection Well | No Violations | I found injection well shut- |
209640194 | 2018-8-3 0:00:0 | SW | No Violations | 1.70 |
2116097950 | 2019-01-07 | Salt Water Injection Well | No Violations | I found the injection well operating during my inspection. The injection well and facility are in good repair. I observed no leaks or spills. Identification signs are posted. There were two (2) Beimel Transportation brine trucks on location with the proper UIC numbers displayed (#25-436). |
287105872 | 2018-2-16 0:00: | SW | No Violations | 0.30 |
310235793 | 2019-1-2 0:00:0 | SW | No Violations | 1.70 |
329929608 | 2020-8-24 0:00: | SW | No Violations | 1.00 |
352637268 | 2019-10-3 0:00: | SW | No Violations | 0.50 |
398990959 | 2018-3-28 0:00: | SW | No Violations | 2.00 |
399457442 | 2018-11-8 0:00: | SW | No Violations | 0.80 |
419609204 | 2019-7-3 0:00:0 | SW | No Violations | 0.30 |
435227131 | 2019-8-20 0:00: | SW | No Violations | 1.00 |
473191958 | 2018-5-18 0:00: | DD | No Violations | 2.50 |
794753008 | 2017-11-27 0:00 | SW | No Violations | 0.40 |
918225664 | 2018-6-4 0:00:0 | SW | No Violations | |
950224719 | 2018-8-8 0:00:0 | SW | No Violations | 0.90 |