If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-157-21601 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.35,"lon":-81.45,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Tuscarawas | |
Municipality: Clay Township | |
Operator Name: ERIC PETROLEUM CORP | |
Well Pad ID: | |
Farm/Lease Name: SHULL WALTER | |
License Status: Producing | |
License Date: 1972-03-22 | |
Spud Date: 1972-08-01 | |
Spud Drilling Contractor: | |
Final Drill Date: 1972-08-10 | |
Well Total Depth: 5010.00 ft | |
Configuration: Vertical | |
Latitude: 40.350000 | |
Longitude: -81.450000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1972-03-22 | 710 WISER OIL CO GeoDate 3/22/72 |
Original Spud | 1972-08-01 | |
Completed | 1972-08-10 | |
Reached Total Depth | 1972-08-10 | |
CO | 1994-12-27 | 5003 FARRAR OIL COMPANY GeoDate 3/22/72 |
Change of Owner | 1999-03-11 | Operator changed from 5003, FARRAR OIL COMPANY to 5054, ERIC PETROLEUM CORP |
Record Last Modified | 2015-03-09 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 4832 | 4896 | 0 |
4832 | 4896 | 0 | |
4832 | 4896 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1350 Bbl | 28000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | WISER OIL CO | 4300.00 | 100.00 | 0 |
1987 | WISER OIL CO | 5006.00 | 102.00 | 365 |
1988 | WISER OIL CO | 6.00 | 100.00 | 365 |
1989 | WISER OIL CO | 5.00 | 75.00 | 365 |
1990 | WISER OIL CO | 5.00 | 75.00 | 365 |
1991 | WISER OIL CO | 5.00 | 75.00 | 365 |
1992 | WISER OIL CO | 4.00 | 75.00 | 365 |
1993 | WISER OIL CO | 4.00 | 75.00 | 365 |
1994 | FARRAR OIL COMPANY | 4.00 | 49.00 | 365 |
1995 | FARRAR OIL COMPANY | 3200.00 | 22.00 | 365 |
1996 | FARRAR OIL COMPANY | 3415.00 | 27.00 | 365 |
1997 | FARRAR OIL COMPANY | 1423.00 | 8.00 | 365 |
1998 | FARRAR OIL COMPANY | 0.00 | 0.00 | 365 |
2001 | ERIC PETROLEUM CORP | 0.00 | 0.00 | 365 |
2002 | ERIC PETROLEUM CORP | 1136.00 | 72.00 | 365 |
2003 | ERIC PETROLEUM CORP | 0.00 | 0.00 | 365 |
2004 | ERIC PETROLEUM CORP | 0.00 | 0.00 | 365 |
2005 | ERIC PETROLEUM CORP | 0.00 | 0.00 | 365 |
2006 | ERIC PETROLEUM CORP | 0.00 | 0.00 | 365 |
2007 | ERIC PETROLEUM CORP | 0.00 | 0.00 | 365 |
2008 | ERIC PETROLEUM CORP | 0.00 | 0.00 | 365 |
2009 | ERIC PETROLEUM CORP | 0.00 | 0.00 | 365 |
2010 | ERIC PETROLEUM CORP | 1122.00 | 0.00 | 365 |
2011 | ERIC PETROLEUM CORP | 0.00 | 0.00 | 365 |
2012 | ERIC PETROLEUM CORP | 1252.00 | 34.00 | 366 |
2013 | ERIC PETROLEUM CORP | 1807.00 | 34.00 | 365 |
2014 | ERIC PETROLEUM CORP | 1963.00 | 36.00 | 365 |
2016 | ERIC PETROLEUM CORP | 2400.00 | 0.00 | 365 |
2017 | ERIC PETROLEUM CORP | 0.00 | 0.00 | 365 |
2018 | ERIC PETROLEUM CORP | 1844.00 | 35.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | WISER OIL CO | Brine | 0 | 0 |
1987 | WISER OIL CO | Brine | 0 | 365 |
1988 | WISER OIL CO | Brine | 0 | 365 |
1989 | WISER OIL CO | Brine | 7 | 365 |
1990 | WISER OIL CO | Brine | 9 | 365 |
1991 | WISER OIL CO | Brine | 0 | 365 |
1992 | WISER OIL CO | Brine | 10 | 365 |
1993 | WISER OIL CO | Brine | 10 | 365 |
1994 | FARRAR OIL COMPANY | Brine | 12 | 365 |
1995 | FARRAR OIL COMPANY | Brine | 0 | 365 |
1996 | FARRAR OIL COMPANY | Brine | 15 | 365 |
1997 | FARRAR OIL COMPANY | Brine | 8 | 365 |
1998 | FARRAR OIL COMPANY | Brine | 0 | 365 |
2001 | ERIC PETROLEUM CORP | Brine | 365 | |
2002 | ERIC PETROLEUM CORP | Brine | 0 | 365 |
2003 | ERIC PETROLEUM CORP | Brine | 0 | 365 |
2004 | ERIC PETROLEUM CORP | Brine | 0 | 365 |
2005 | ERIC PETROLEUM CORP | Brine | 0 | 365 |
2006 | ERIC PETROLEUM CORP | Brine | 0 | 365 |
2007 | ERIC PETROLEUM CORP | Brine | 0 | 365 |
2008 | ERIC PETROLEUM CORP | Brine | 365 | |
2009 | ERIC PETROLEUM CORP | Brine | 0 | 365 |
2010 | ERIC PETROLEUM CORP | Brine | 0 | 365 |
2011 | ERIC PETROLEUM CORP | Brine | 0 | 365 |
2012 | ERIC PETROLEUM CORP | Brine | 0 | 366 |
2013 | ERIC PETROLEUM CORP | Brine | 0 | 365 |
2014 | ERIC PETROLEUM CORP | Brine | 10 | 365 |
2016 | ERIC PETROLEUM CORP | Brine | 0 | 365 |
2017 | ERIC PETROLEUM CORP | Brine | 0 | 365 |
2018 | ERIC PETROLEUM CORP | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0551268732 | 2018-10-29 | Production Wells | No Violations | Upon arrival on location, I witnessed the well was equipped 4.5 inch diameter casing, 2.375 inch diameter tubing, and a plunger lift system. The valves were open on tubing and one of two valves were open on the casing. Domestic gas was being supplied off the 4.5 inch casing. Production equipment included a steel 100 barrel tank, a horizonal separator, and a chart recorder with an .750 orifice plate within an earthen dike. The production equipment was being shared with the Shull 1 (2036). The production report was up to date and proper identification was present. |
1335181953 | 2012-04-23 | Production Wells | Violations Noted | Arrived on location and found well idle and no I.d. posted. I returne to my office and checked production reports and found none submitted as of this date, within 30 days place well into production or apply for a plug permit, post I.D, and submit production reports. |
1357741341 | 2013-01-09 | Production Wells | No Violations | Arrived on this location and met with Eric Hoffman of Eric Petroleum we ran the rabbit on this well which produced fluid into the tank battery at which time I found violations for this well corrected. The identification sign has been posted , the well is in production and all production reports have been received. Note: production reports were received on 06/05/2012. Case closed on 01/09/2013. |
1357743991 | 2013-01-02 | Production Wells | No Violations | I arrived on this location to see if well is in production. Cant tell without running the rabbit. I will call and have the pumper meet me so we can pump well. |
551268732 | 2018-10-29 0:00 | PW | No Violations | 0.70 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1335181953 | US-OH-109646 | 2014-04-10 | Failure to legibly identify well | |
1335181953 | US-OH-109647 | 2014-04-10 | Temporary inactive; failure to comply with terms or conditions of the permit, rules, or orders | |
1335181953 | US-OH-109648 | 2014-04-10 | Statement of annual production not filed |
For data sources see[9]