If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-157-22739 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.45,"lon":-81.55,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Tuscarawas | |
Municipality: York Township | |
Operator Name: BOWER OIL & GAS LLC | |
Well Pad ID: | |
Farm/Lease Name: MILLER | |
License Status: Producing | |
License Date: 1976-12-22 | |
Spud Date: 1976-12-12 | |
Spud Drilling Contractor: | |
Final Drill Date: 1977-01-20 | |
Well Total Depth: 4797.00 ft | |
Configuration: Vertical | |
Latitude: 40.450000 | |
Longitude: -81.550000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1976-12-12 | |
Completed | 1977-01-20 | |
Reached Total Depth | 1977-01-20 | |
Record Last Modified | 2013-10-03 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 4587 | 4680 | 18 |
4587 | 4680 | 18 | |
4587 | 4680 | 18 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1975 Bbl | 70000 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1120760424 | 2003-2-11 0:00: | PW | No Violations | |
-1675252291 | 2019-1-10 0:00: | PW | No Violations | 0.90 |
-1978120896 | 2019-10-29 0:00 | PW | No Violations | 1.30 |
0293916917 | 2017-08-09 | Production Wells | Violations Noted | On the day of my inspection I found the well equipped with 8 5/8 inch diameter casing 4 1/2 inch diameter casing, and 1 1/2 inch diameter tubing, operated by a plunger lift system. The well was idle this day, the outlet valve and the domestic gas valve are in the closed position. The production equipment is made up of one 210 bbl. steel tank, one inground 50 bbl. steel tank, one horizontal separator. The production reporting is up to date, and the well does not have any identification. According to the landowner the well has not provided gas for two years. The production equipment is shared with well 34-157-2-3737. The well needs plugged and abandon. The last production was in the year of 2014. There is a 30 bbl. plastic tank on location that is not hooked up to the well.
Snyder Oil needs to submit a written plugging schedule to Inspector Randy Akins at 2207 Reiser Ave. New Philadelphia, Ohio, 44663 within 30 day, per OAC 1501:9-11-05(B), and plug the well within 180 days. The owner/operator will be notified if the plugging schedule is approved or denied. |
1120760424 | 2003-02-11 | Production Wells | No Violations | violation corrected. |
1323094802 | 2011-11-29 | Production Wells | Violations Noted | Arrived on location and found well idle, two wells are being used by the same tank battery and both have the same production recorded for the past years, With in 30 days place a meter on permit # 2739 and permit # 2736, |
1383586814 | 2013-10-16 | Production Wells | No Violations | I arrived on location and found this well has been equipped with a meter . Violation has been corrected, case closed on 10/16/13 |
1528457353 | 2018-05-24 | Production Wells | No Violations | This inspection was a follow up to a compliance notice number 293916917, issued on 10/06/2017. Upon arrival on location, I witnessed the well was in the idle position. The well was equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, 1.5 inch diameter tubing, and a plunger lift system. The domestic gas and the gas sales line valves were in the closed position. A plastic 30 barrel tank was located by the well, but was not connected. |
1566394922 | 2019-8-21 0:00: | PW | No Violations | 0.30 |
1583163401 | 2020-3-2 0:00:0 | PW | No Violations | 1.50 |
1675252291 | 2019-01-10 | Production Wells | No Violations | This inspection was a follow up to a compliance notice number 293916917, issued on 10/06/2017 by Randy Akins. Upon arrival on location, with the ground covered with snow, I witnessed the well was in the idle position. The well was equipped with 8.625 inch diameter casing, 4.5 inch diameter casing, 1.5 inch diameter tubing, and a plunger lift system. The domestic gas and the gas sales line valves were in the closed position. A plastic 30 barrel tank was located by the well, but was not connected. I tried contacting the well owner about this well. I left messages on two different phone numbers. |
293916917 | 2017-8-9 0:00:0 | PW | No Violations | 0.70 |
612084801 | 2019-10-29 0:00 | PW | No Violations | 0.30 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0293916917 | US-OH-123062 | 2017-10-12 | Failure to legibly identify well | |
0293916917 | US-OH-123063 | 2017-10-12 | Well shall be plugged | |
1323094802 | US-OH-109242 | 2011-12-05 | Temporary inactive; failure to properly shut-in or maintain the well or associated equipment |
For data sources see[9]