X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-157-23180

Well Details

Well ID: 34-157-23180
Loading map...
Country: United States
State: Ohio
County: Tuscarawas
Municipality: Perry Township
Operator Name: OWENS ROBERT & LETTY
Well Pad ID:
Farm/Lease Name: OWENS
License Status: Final Restoration
License Date: 2014-01-22
Spud Date: 1979-01-25
Spud Drilling Contractor:
Final Drill Date: 1979-02-01
Well Total Depth: 5892.00 ft
Configuration: Vertical
Latitude: 40.230000
Longitude: -81.350000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1979-01-16 140 KST OIL & GAS CO INC GeoDate 1/16/79
Original Spud 1979-01-25 R.I. 1-24-79
Completed 1979-02-01 R.I. 1-24-79
Reached Total Depth 1979-02-01 R.I. 1-24-79
CO 1995-12-05 182 BELDEN & BLAKE CO GeoDate 1/16/79
Change of Owner 2000-02-28 Operator changed from 182, BELDEN & BLAKE CORPORATION to 5601, MOORE WELL SERVICES INC
Change of Owner 2013-07-16 Operator changed from 5601, MOORE WELL SERVICES INC to 9150, NIGHTHAWK HOLDINGS LLC
Change of Owner 2014-01-15 Operator changed from 9150, NIGHTHAWK HOLDINGS LLC to 9224, OWENS ROBERT & LETTY
APP 2014-01-22 Proposed Formations:CLINTON, Issued Date:1/22/2014, Expired Date:1/22/2016 12:00:00 PM, Drilling unit acres:260.64, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2014-02-18 R.I. 1-24-79
Construction Permit Expires 2016-01-22 R.I. 1-24-79
Record Last Modified 2017-02-10 R.I. 1-24-79

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5618 5778 14
5618 5778 14
5618 5778 14

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 76500 Gal 100000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1995 BELDEN & BLAKE CORPORATION 892.00 0.00 32
1996 BELDEN & BLAKE CORPORATION 1148.00 0.00 245
2000 MOORE WELL SERVICES INC 0.00 0.00 0
2001 MOORE WELL SERVICES INC 0.00 0.00 0
2002 MOORE WELL SERVICES INC 0.00 0.00 0
2003 MOORE WELL SERVICES INC 0.00 0.00 0
2004 MOORE WELL SERVICES INC 0.00 0.00 0
2005 MOORE WELL SERVICES INC 0.00 0.00 0
2006 MOORE WELL SERVICES INC 0.00 0.00 0
2007 MOORE WELL SERVICES INC 0.00 0.00 0
2008 MOORE WELL SERVICES INC 0.00 0.00 0
2009 MOORE WELL SERVICES INC 0.00 0.00 0
2010 MOORE WELL SERVICES INC 0.00 0.00 0
2011 MOORE WELL SERVICES INC 0.00 0.00 0
2012 MOORE WELL SERVICES INC 0.00 0.00 0
2013 MOORE WELL SERVICES INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1995 BELDEN & BLAKE CORPORATION Brine 0 32
1996 BELDEN & BLAKE CORPORATION Brine 54 245
2000 MOORE WELL SERVICES INC Brine 0 0
2001 MOORE WELL SERVICES INC Brine 0 0
2002 MOORE WELL SERVICES INC Brine 0 0
2003 MOORE WELL SERVICES INC Brine
2004 MOORE WELL SERVICES INC Brine 0 0
2005 MOORE WELL SERVICES INC Brine 0 0
2006 MOORE WELL SERVICES INC Brine 0 0
2007 MOORE WELL SERVICES INC Brine 0 0
2008 MOORE WELL SERVICES INC Brine 0 0
2009 MOORE WELL SERVICES INC Brine 0 0
2010 MOORE WELL SERVICES INC Brine 0 0
2011 MOORE WELL SERVICES INC Brine 0 0
2012 MOORE WELL SERVICES INC Brine 0 0
2013 NIGHTHAWK HOLDINGS LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1392388956 2014-02-14 Plug / Plug Back No Violations I am on site today to plug this well with Glenn Davis Well Service and Formation Cementing Service. Davis has 2-3/8 inch diameter tubing @ 5680 ft. Formation will set a 200 ft plug from 5680 ft to 5480 ft c/w 25 sks. Davis pulled 49 jts of tubing up to where the 4-1/2 inch diameter casing has been perfed at 4100 ft per Inspector Grimm. Set plug # 2 from 4100 ft to 3900 ft c/w 59 sks. Then all of the tubing will be pulled and Davis will try and rip the 4-1/2 inch diameter casing and pull it all out and run back in with tubing to finish plugging the well to surface.
1400600231 2014-05-20 Final Restoration No Violations On the day of my inspection accompanied by Intern Austin Gutridge, I witnessed that the site did not pass final restoration according to 1509.072B. I made call to Nighthawk Holdings at 330-674-5391 and spoke with Rob Hunter and stated that the equipment needs to be removed and he stated that it would be done this week and would notify me when done so that a follow up inspection could be completed.
1891231112 2016-05-05 Final Restoration No Violations On the day of my inspection I found that the final restoration has been completed. The site passed final restoration according to ORC 1509.072 (B)

For data sources see[9]