If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-157-23288 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.41,"lon":-81.58,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Tuscarawas | |
Municipality: Jefferson Township | |
Operator Name: SOUND ENERGY CO INC | |
Well Pad ID: | |
Farm/Lease Name: GOWINS DALE | |
License Status: Producing | |
License Date: 1978-12-21 | |
Spud Date: 1979-01-18 | |
Spud Drilling Contractor: | |
Final Drill Date: 1979-01-24 | |
Well Total Depth: 4919.00 ft | |
Configuration: Vertical | |
Latitude: 40.410000 | |
Longitude: -81.580000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1978-12-21 | 2559 WNT OPERATING INC GeoDate 12/21/78 |
Original Spud | 1979-01-18 | |
Completed | 1979-01-24 | |
Reached Total Depth | 1979-01-24 | |
Change of Owner | 2001-09-05 | Operator changed from 2559, WNT OPERATING INC to 2543, TIPKA ENERGY DEVLOP CO |
Record Last Modified | 2019-06-04 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 4746 | 4815 | 15 |
4746 | 4815 | 15 | |
4746 | 4815 | 15 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 68000 Gal | 57000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | TIPKA WILLIAM N | 7346.00 | 69.00 | 365 |
1985 | TIPKA WILLIAM N | 6733.00 | 0.00 | 0 |
1986 | WNT OPERATING INC | 5594.00 | 0.00 | 365 |
1987 | WNT OPERATING INC | 4727.00 | 60.00 | 365 |
1988 | WNT OPERATING INC | 4655.00 | 0.00 | 365 |
1989 | WNT OPERATING INC | 4921.00 | 0.00 | 365 |
1990 | WNT OPERATING INC | 5374.00 | 62.00 | 365 |
1991 | WNT OPERATING INC | 4711.00 | 0.00 | 365 |
1992 | WNT OPERATING INC | 4731.00 | 0.00 | 365 |
1993 | WNT OPERATING INC | 4327.00 | 0.00 | 365 |
1994 | WNT OPERATING INC | 4116.00 | 0.00 | 365 |
1995 | WNT OPERATING INC | 4105.00 | 0.00 | 365 |
1996 | WNT OPERATING INC | 3765.00 | 0.00 | 366 |
1997 | WNT OPERATING INC | 4090.00 | 61.00 | 365 |
1999 | WNT OPERATING INC | 3263.00 | 0.00 | 365 |
2000 | WNT OPERATING INC | 3086.00 | 0.00 | 366 |
2001 | TIPKA ENERGY DEVLOPMENT COMPAN | 2775.00 | 0.00 | 365 |
2002 | TIPKA ENERGY DEVLOPMENT COMPAN | 2280.00 | 0.00 | 365 |
2003 | TIPKA ENERGY DEVLOPMENT COMPAN | 1711.00 | 0.00 | 365 |
2004 | TIPKA ENERGY DEVLOPMENT COMPAN | 724.00 | 0.00 | 366 |
2005 | TIPKA ENERGY DEVLOPMENT COMPAN | 1658.00 | 0.00 | 365 |
2006 | TIPKA ENERGY DEVLOPMENT COMPAN | 1589.00 | 0.00 | 365 |
2007 | TIPKA ENERGY DEVLOPMENT COMPAN | 1168.00 | 0.00 | 365 |
2008 | TIPKA ENERGY DEVLOPMENT COMPAN | 1288.00 | 0.00 | 366 |
2009 | TIPKA ENERGY DEVLOPMENT COMPAN | 1230.00 | 0.00 | 365 |
2010 | TIPKA ENERGY DEVLOPMENT COMPAN | 1119.00 | 0.00 | 365 |
2011 | TIPKA ENERGY DEVLOPMENT COMPAN | 1189.00 | 0.00 | 0 |
2012 | TIPKA ENERGY DEVLOPMENT COMPAN | 892.00 | 0.00 | 366 |
2013 | TIPKA ENERGY DEVLOPMENT COMPAN | 911.00 | 0.00 | 365 |
2014 | TIPKA ENERGY DEVLOPMENT COMPAN | 898.00 | 0.00 | 365 |
2015 | TIPKA ENERGY DEVLOPMENT COMPAN | 577.00 | 0.00 | 365 |
2016 | TIPKA ENERGY DEVLOPMENT COMPAN | 206.00 | 0.00 | 366 |
2017 | TIPKA ENERGY DEVLOPMENT COMPAN | 0.00 | 0.00 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0000PL3198 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
1456405575 | 2016-02-25 | Production Wells | No Violations | On the day of my inspection I found a 4 inch casing with a 4 X 2 swage on top with a 2 inch valve. The well is a swab well. The valve is in the open position. The tank battery is made up of one 100 bbl. tank in an earthen dike. A horizontal separator and a 2 inch meter run with a recording gauge. The tank is properly identified, the production reporting is up to date, and there are no violations at this time. |
1868051343 | 2019-7-30 0:00: | PW | No Violations | 0.30 |
PL3198 | PL | No Violations |
For data sources see[9]