If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-157-24311 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.33,"lon":-81.45,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Tuscarawas | |
Municipality: Clay Township | |
Operator Name: MAINSPRING LLC | |
Well Pad ID: | |
Farm/Lease Name: GARRETT NORA | |
License Status: Active Injection | |
License Date: 1985-08-13 | |
Spud Date: 1985-11-09 | |
Spud Drilling Contractor: GREGS DRLG | |
Final Drill Date: 1985-12-24 | |
Well Total Depth: 975.00 ft | |
Configuration: Vertical | |
Latitude: 40.330000 | |
Longitude: -81.450000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1985-08-13 | 2203 HALTER RALPH P GeoDate 8/13/85 |
Conversion to Injector | 1985-08-13 | |
Salt Water Injection Well | 1985-08-13 | Issued Date 8/13/85 Expired Date 8/13/86 Acres 0100000 Tool Type CT Proposed Formation BEREA Proposed Depth 00975 Proposed Drill Depth 00975 |
Storage Well | 1985-08-13 | Issued Date 8/13/85 Expired Date 8/13/86 Acres 0100000 Tool Type CT Proposed Formation BEREA Proposed Depth 00975 Proposed Drill Depth 00975 |
Original Spud | 1985-10-09 | FDT=GRAY |
Completed | 1985-12-24 | FDT=GRAY |
Reached Total Depth | 1985-12-24 | FDT=GRAY |
First Injection | 1986-01-01 | FDT=GRAY |
Construction Permit Expires | 1986-08-13 | FDT=GRAY |
Water Analysis | 1986-08-15 | FDT=GRAY |
Completion Report Received | 1987-05-05 | FDT=GRAY |
Change of Owner | 1998-06-12 | Operator changed from 2203, HALTER RALPH P to 1586, L L P OIL & GAS CORP |
Annulus Pressure Monitoring Approved | 1999-02-26 | FDT=GRAY |
Last Compliance Report | 2013-08-19 | FDT=GRAY |
Record Last Modified | 2017-10-19 | FDT=GRAY |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2000-05-08 | 870 | 960 | 0 |
870 | 960 | 0 | |
870 | 960 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
0 | 0 | 0 | NONE |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2005 | LLP GAS AND OIL CORPORATION | 0.00 | 76.00 | 365 |
2006 | LLP GAS AND OIL CORPORATION | 0.00 | 0.00 | 0 |
2007 | LLP GAS AND OIL CORPORATION | 0.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2005 | LLP GAS AND OIL CORPORATION | Brine | 0 | 365 |
2006 | LLP GAS AND OIL CORPORATION | Brine | 0 | |
2007 | LLP GAS AND OIL CORPORATION | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1028759653 | 2007-5-1 0:00:0 | SW | No Violations | 1.50 |
-1097452912 | 2004-12-22 0:00 | SW | No Violations | 1.50 |
-1114214867 | 2007-10-24 0:00 | SW | No Violations | 1.00 |
-1157862465 | 2012-1-19 0:00: | SW | No Violations | 1.50 |
-1179952965 | 2016-11-7 0:00: | SW | No Violations | |
-1213231040 | 2006-9-6 0:00:0 | SW | No Violations | 1.50 |
-1231275810 | 2008-12-5 0:00: | SW | No Violations | 1.50 |
-126334627 | 2006-9-21 0:00: | SW | No Violations | 1.50 |
-127933794 | 2017-10-4 0:00: | SW | No Violations | |
-1308190512 | 2011-8-3 0:00:0 | SW | No Violations | 1.50 |
-1315352068 | 2019-4-14 0:00: | SC | No Violations | |
-1346634042 | 2009-11-23 0:00 | SW | No Violations | 1.50 |
-1359651030 | 2007-7-3 0:00:0 | SW | No Violations | 2.00 |
-13857594 | 2008-4-29 0:00: | SW | No Violations | 1.50 |
-1390315933 | 2011-10-13 0:00 | SW | No Violations | 1.50 |
-1397558288 | 2010-11-23 0:00 | SW | No Violations | 1.50 |
-1467257015 | 2011-7-26 0:00: | SW | No Violations | 2.50 |
-1484459087 | 2013-8-12 0:00: | SW | No Violations | |
-1485226404 | 2015-10-19 0:00 | SW | No Violations | |
-1496054432 | 2016-10-21 0:00 | SW | No Violations | |
-149654150 | 2011-5-3 0:00:0 | SW | No Violations | 2.00 |
-1501157587 | 2016-8-23 0:00: | SW | No Violations | |
-1527453881 | 2014-2-24 0:00: | SW | No Violations | |
-1542997480 | 2003-11-4 0:00: | SW | No Violations | 1.20 |
-15685485 | 2007-12-13 0:00 | SW | No Violations | 1.50 |
-1638111496 | 2019-8-5 0:00:0 | SW | No Violations | |
-1640707720 | 2011-7-26 0:00: | SW | No Violations | 2.50 |
-1642237382 | 2004-1-30 0:00: | SW | No Violations | 1.20 |
-1688098130 | 2017-11-14 0:00 | SW | No Violations | |
-1690359665 | 2014-10-6 0:00: | SW | No Violations | |
-1690366222 | 2012-6-15 0:00: | SW | No Violations | 1.50 |
-1721693771 | 2012-8-15 0:00: | SW | No Violations | 1.50 |
-1764682206 | 2007-7-25 0:00: | SW | No Violations | 1.00 |
-1781496097 | 2017-6-1 0:00:0 | SW | No Violations | |
-1787178034 | 2013-3-4 0:00:0 | SW | No Violations | |
-1814978144 | 2009-4-13 0:00: | SW | No Violations | 0.50 |
-1843906622 | 2006-3-16 0:00: | SW | No Violations | 1.50 |
-1873354065 | 2008-2-20 0:00: | SW | No Violations | 1.50 |
-1886849670 | 2005-7-7 0:00:0 | SW | No Violations | 1.50 |
-1903028564 | 2018-1-24 0:00: | SW | No Violations | |
-1903697435 | 2013-10-17 0:00 | SW | No Violations | |
-1910542869 | 2013-4-10 0:00: | SW | No Violations | |
-1946671777 | 2005-9-7 0:00:0 | SW | No Violations | 2.50 |
-1982788968 | 2006-10-30 0:00 | SW | No Violations | 1.50 |
-1998071349 | 2008-9-8 0:00:0 | SW | No Violations | 1.50 |
-2070568454 | 2014-4-16 0:00: | SW | No Violations | |
-2083311480 | 2006-2-10 0:00: | SW | No Violations | 1.50 |
-217730419 | 2019-2-11 0:00: | SW | No Violations | |
-2203256 | 2005-3-9 0:00:0 | SW | No Violations | 1.20 |
-239325582 | 2006-1-20 0:00: | SW | No Violations | 1.50 |
-242784464 | 2003-4-16 0:00: | SW | No Violations | 1.50 |
-2447178 | 2018-3-5 0:00:0 | SW | No Violations | |
-252847937 | 2010-6-16 0:00: | SW | No Violations | 1.00 |
-258523161 | 2009-1-6 0:00:0 | SW | No Violations | 2.20 |
-28958460 | 2007-2-23 0:00: | SW | No Violations | 1.50 |
-293928808 | 2019-8-30 0:00: | SW | No Violations | |
-35601521 | 2008-9-3 0:00:0 | SW | No Violations | 2.00 |
-446612777 | 2013-6-4 0:00:0 | SW | No Violations | |
-477855220 | 2008-4-14 0:00: | SW | No Violations | 1.50 |
-489691742 | 2016-3-10 0:00: | SW | No Violations | |
-507036618 | 2006-1-27 0:00: | SW | No Violations | 1.50 |
-516149948 | 2006-5-9 0:00:0 | SW | No Violations | 1.50 |
-543430886 | 2008-4-15 0:00: | SW | No Violations | 3.00 |
-582995211 | 2018-2-28 0:00: | SW | No Violations | |
-588848110 | 2012-4-11 0:00: | SW | No Violations | 1.50 |
-590616108 | 2006-12-6 0:00: | SW | No Violations | 1.00 |
-648614312 | 2010-3-31 0:00: | SW | No Violations | 1.50 |
-652281072 | 2006-7-25 0:00: | SW | No Violations | 1.50 |
-659925952 | 2009-9-17 0:00: | SW | No Violations | 1.50 |
-661700628 | 2015-7-30 0:00: | SW | No Violations | |
-664226376 | 2010-6-9 0:00:0 | SW | No Violations | 1.50 |
-73378877 | 2017-2-15 0:00: | SW | No Violations | |
-800696476 | 2012-2-27 0:00: | SW | No Violations | 2.50 |
-859059203 | 2014-1-6 0:00:0 | SW | No Violations | |
-875216615 | 2012-2-1 0:00:0 | SW | No Violations | 1.50 |
-901374467 | 2009-12-10 0:00 | SW | No Violations | 1.50 |
-962807505 | 2007-1-22 0:00: | SW | No Violations | 1.50 |
-980252102 | 2006-8-16 0:00: | SW | No Violations | 1.50 |
-981086853 | 2015-11-25 0:00 | SW | No Violations | |
-984682564 | 2011-3-29 0:00: | SW | No Violations | 1.50 |
-999254712 | 2006-12-5 0:00: | SW | No Violations | 3.00 |
0000000460 | 2002-10-16 | Salt Water Injection Well | No Violations | |
0000PL2647 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0000UIC214 | 1987-06-10 | Salt Water Injection Well | No Violations | 1509.22 (A)(1)(2)(C)(3) |
0000UIC215 | 1987-06-10 | Salt Water Injection Well | No Violations | 1501:9-3-04(A) |
0000UIC216 | 1987-06-10 | Salt Water Injection Well | No Violations | 15019-3-05 (A)(6) |
0000UIC256 | 1987-08-03 | Salt Water Injection Well | No Violations | 1509.03 |
0000UIC257 | 1987-08-03 | Salt Water Injection Well | No Violations | 1509.072 |
0000UIC810 | 1989-11-28 | Salt Water Injection Well | No Violations | 1501:9-3-08 (B) Temporary storage |
0000UIC887 | 1990-04-20 | Salt Water Injection Well | No Violations | 1509.22(A) STORAGE & DISPOSAL |
0000UIC888 | 1990-04-20 | Salt Water Injection Well | No Violations | 1509.22(A) PREVENTION AND CONTA |
0001239i76 | 2001-11-01 | Salt Water Injection Well | No Violations | The new tank facility is almost ready to be hooked up. The operator is to call when he is to continue work. |
0002203256 | 2005-03-09 | Salt Water Injection Well | No Violations | Met again with Mark Clark and he said that he send the part back and the replacement was coming to fix his meter. |
0002447178 | 2018-03-05 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation during my inspection and well owner Mark Clark was on site to test Murphy switch to verify that it works properly switch shut down pump at 720 psi which is 5psi below maximum allowable injection pressure. |
0003351226 | 2009-04-17 | Production Wells | Violations Noted | Had anonymous call of oil running over tanks .Arrived and found that the production tanks for the Garret lease have been run over .The inside of the dike is full of oil .The oil is running under the dike and down to the ditch in front of the tanks along the road . Contact Mark Clark and he said he would have somebody there within the hour. I returned and found that the clean up is under way with peat sorb and small pillows collecting the oil. Returned to the New Phila office to shut off the lights and turn off computer , fuel up vehicle .When I returned I found nobody around.The clean up was only done enough to keep it from running out of the dike and now everyone is gone.Contact Inspector Grimm and advise that it was the production side of the injection wells .He advised that if I was there to go ahead and handle clean up and issue NOV. |
0007675910 | Salt Water Injection Well | No Violations | The new tank facility is almost ready to be hooked up. The operator is to call when he is to continue work. | |
000UIC1482 | 1993-10-14 | Salt Water Injection Well | No Violations | 1501: 9-1-07 POLLUTION |
000UIC1483 | 1993-10-14 | Salt Water Injection Well | No Violations | 1501: 9-3-04 (A) PREVENT CONTAMINATE |
0013857594 | 2008-04-29 | Salt Water Injection Well | No Violations | Check on clean up and found tanks over run with brine and oil.Contact Mark Clark and advise of clean up again.He is to have equipnent there soon.Within days. |
0013975987 | 2002-02-15 | Salt Water Injection Well | No Violations | Met with Mark Clark at the facility and went over changes being made to the tanks and pumphouse. |
0015685485 | 2007-12-13 | Salt Water Injection Well | No Violations | Tried lock combo for the barrel counter and it did not work . |
0018076035 | 2002-03-25 | Salt Water Injection Well | No Violations | Met with Mark Clark on plugging wells for State Orphan program. |
0024254297 | 2009-07-28 | Salt Water Injection Well | No Violations | Dike is not over full and well is not in operation.Review production tanks and clean up with Inspector Grimm. |
0028958460 | 2007-02-23 | Salt Water Injection Well | No Violations | Too much ice on steps to check barrel counter . |
0030919163 | 2016-02-01 | Salt Water Injection Well | No Violations | Injection pump was not in operation during my inspection. |
0032376125 | 2002-07-08 | Salt Water Injection Well | No Violations | Return to check this well to make sure that there was not a spill after lines have been relocated. Check this well with Inspector Grimm.Pressure not checked during this inspection . |
0032876130 | 2002-07-02 | Salt Water Injection Well | No Violations | Talk with Mark Clark and he advised that he will be changing lines and may have alittle oil to clean up around bottom of pumphouse. Check this well with Inspector Grimm. |
0035601521 | 2008-09-03 | Salt Water Injection Well | Violations Noted | Dike is full and will need pumped off ASAP. Dike also appears to be leaking under liner .Conact Mark Clark and advise that dike is full and about to over flow.Talk about possilbe leak in liner also. |
0038776006 | 2002-08-20 | Salt Water Injection Well | No Violations | |
0073378877 | 2017-02-15 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection and it was noted that new plumbing has been installed on injection pump. |
0074392376 | 2006-07-18 | Salt Water Injection Well | No Violations | Review site for clean up and found that there is very little done.Review site with Inspector Grimm |
0126334627 | 2006-09-21 | Salt Water Injection Well | No Violations | Still no flow meter .Left message for Mark Clark to install meter controll so that monitoring can begin . |
0127933794 | 2017-10-04 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was not in operation during my inspection. |
0149654150 | 2011-05-03 | Salt Water Injection Well | No Violations | Dike is empty of fluid. |
0182816782 | 2009-06-17 | Salt Water Injection Well | No Violations | The inside of the dike is about 1/4 of the way filled. Contact operator Mark Clark and advise that dike is filling up. Also advise that more peat sorb is needed in the next dike over for the production tanks . |
0212490542 | 2010-01-25 | Salt Water Injection Well | No Violations | Just check dike today because we have had a ton of rain the last few days.Found that the dike has some fluid in it but it is not too high ,could be pumped down now that it is not frozen.Well not in operation |
0215171228 | 2004-09-28 | Salt Water Injection Well | No Violations | No flow meter connected to system at this time.Talk again to Mark Clark and advised again that a flowmeter was part of his permit conditions and would need to be installed ASAP. |
0217730419 | 2019-02-11 | Salt Water Injection Well | Violations Noted | The Division has not received the 1st, 2nd, 3rd, & 4th quarter brine disposal fees for 2018. Please forward disposal fees and sheets to the Division by 3/12/2019. |
0239325582 | 2006-01-20 | Salt Water Injection Well | No Violations | Met with Mark Clark and found that flowmeter is on but is not working correctly and needs to be programed.He is to have somebody do that this week. |
0242784464 | 2003-04-16 | Salt Water Injection Well | No Violations | Talk with Mark Clark on placing a meter back on injection side to monitor barrels . Mark told me he has one ordered and as soon as it arrives he will install it . |
0246266890 | 2018-03-01 | Salt Water Injection Well | Violations Noted | The Division received annual report form 204. Review of the form 204 revealed an exceedance of the maximum allowable injection pressure. The injection pressure shall be reduced and the auto shut down switch shall be adjusted to the maximum allowable injection pressure. A follow-up inspection will be conducted. |
0252847937 | 2010-06-16 | Salt Water Injection Well | No Violations | Check dike level and found it dry - well not in operation |
0258523161 | 2009-01-06 | Salt Water Injection Well | No Violations | Had tip that I needed to check out this well again .Found everything frozen inside pumphouse.Doors and windows are open and no heat on .Pump appears to have broken due to the cold .Dike is at 1/2 full.There is not enough room left inside the dike for a tank failure.Contact Mark Clark and advise on what I found .Did not get hold of him? |
0275799393 | 2009-06-01 | Salt Water Injection Well | No Violations | Check dike for fluid level and found that dike has been pumped free of fluid. Well does not appear to be in operation . The production tanks next to this facility have been run over. There is peat sorbs down inside the dike . The inside of the dike should be cleaned up after the peat sorbs has collected as much of the oil as it can . Contact Inspector Grimm and advise and he said for me to handle the clean up when I return for Injection inspection . |
0276756343 | 2010-03-12 | Salt Water Injection Well | No Violations | No injection at this inspection.Dike is full and needs pumped off. |
0288768423 | 2006-02-06 | Salt Water Injection Well | No Violations | Flowmeter is not currently connected.Still has a programming problem. |
0344385434 | 2007-08-14 | Salt Water Injection Well | No Violations | Area still flooded and barrel counter could not be checked.Contacted Mark Clark and he said that barrel counter will be fixed Wedsday 8/15/2007 |
0410821013 | 2008-05-16 | Salt Water Injection Well | Violations Noted | Whle checking dike and clean up around dike I found another leak on the same side as the dike.There are now two clean up areas needed along with the dike area and below the pumphouse.Contacted Mark Clark and then met with clean up crew on site .Mark is to |
0423019147 | 2008-09-04 | Salt Water Injection Well | No Violations | Dike pumped off .The area in front of dike has been excavated and removed and is now dry, but so is dike.Need to check again after there is fluid inside of dike again.Well not operating at this time. |
0432841398 | 2010-04-13 | Salt Water Injection Well | No Violations | Well does not appear to be in operation. Dike is empty of fluid |
0435047237 | 2018-06-01 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection. |
0437381003 | 2005-08-04 | Salt Water Injection Well | No Violations | Check to see if flowmeter has been installed and found that it has not.Try and contact Mark Clark to re-issue NOV |
0446612777 | 2013-06-04 | Salt Water Injection Well | No Violations | Omega Cementing on site to set a 100 cement plug on top of bridge plug set@852 owner will attempt to squeeze cement into casing hole later this week. |
0471432932 | 2011-10-13 | Salt Water Injection Well | Violations Noted | Met with well crew on site and went over leaks and spills. Also went over what needs cleaned up and the repairs to be made. The production tanks need to be removed from the dike and clean up of all old oil and brine completed. The brine on the back side of the injection well dike, as well as the area behind the pumphouse over to the retaining pond needs cleaned up. The dike liner is torn and needs repaired or replaced. Well pressure was not checked. |
0477855220 | 2008-04-14 | Salt Water Injection Well | Violations Noted | Found mess around tank battery and pumphouse is locked area is under water and covered in oil .It is not safe to check barrel counter with brine and this electrical set up. |
0480767146 | 2003-07-10 | Salt Water Injection Well | No Violations | Flow meter is back ordered. |
0480947385 | 2009-04-30 | Salt Water Injection Well | No Violations | Check on clean up and found that there is peat sorb on top of all of the oil.There has been no other clean up done at this time. Well is not in operation and maybe the entire field is shut in. |
0489691742 | 2016-03-10 | Salt Water Injection Well | No Violations | Injection pump not in operation during my inspection. |
0500221194 | 2013-07-24 | Salt Water Injection Well | No Violations | Bishop Well Service on site rigging up preparing to drill cement out from inside of casing after recent squeeze job on casing |
0507036618 | 2006-01-27 | Salt Water Injection Well | No Violations | There has been some progress on the flowmeter ,but it is still not recording barrels correctly. |
0516149948 | 2006-05-09 | Salt Water Injection Well | No Violations | The pumphouse has a leak and the flowmeter that was hooked up has been removed ? |
0518195341 | 2003-09-15 | Salt Water Injection Well | No Violations | Talked to Mark Clark and he said that the flow meter has been ordered and should be installed on my next regular inspection. |
0543430886 | 2008-04-15 | Salt Water Injection Well | Violations Noted | while checking to see if dike has been pumped off I found an oil leak on the other side of the hill .Contact Mark Clark and advise of leak.Found that dike has not been pumped off. |
0566963086 | 2006-07-12 | Salt Water Injection Well | Violations Noted | I found that the packing was leaking and all of the fluid was bypassing the vault.The pump for the vault was connected to a pipe outside the dike .All of the fluid that was leaking out of the pump packing was being pumped out on the ground .I also found that the old building which holds the oil drums has had a spill ? I have contacted Mark Clark and will meet him on site to review clean up. |
0582995211 | 2018-02-28 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection |
0583338642 | 2006-07-21 | Salt Water Injection Well | No Violations | Met Mark Clark and clean up crew on site and went over everything that needs cleaned up. |
0588848110 | 2012-04-11 | Salt Water Injection Well | No Violations | The inside of the dike is free of fluid. The repairs to the liner and the dike wall have not been completed at this time. |
0590616108 | 2006-12-06 | Salt Water Injection Well | No Violations | The barrel counter has been installed . |
0612957075 | 2008-04-18 | Salt Water Injection Well | No Violations | Check on clean up and dike level.Found no fluid pumped .Dike remains almost full. |
0648614312 | 2010-03-31 | Salt Water Injection Well | No Violations | The well is not in operation.The dike is free of fluid . |
0652281072 | 2006-07-25 | Salt Water Injection Well | No Violations | Check to see if clean up is done and found out that not much has been done.Packing leaking again on the pump.It is not being pumped out on the ground during this inspection.Contact Mark Clark and advise of packing leak. |
0654210810 | 2008-06-19 | Salt Water Injection Well | Violations Noted | The inside of the dike is flooded and there is less than 50 bbls of space left from going over the top of the dike.The left corner is also too low and will need to be pushed up for more containment. |
0659925952 | 2009-09-17 | Salt Water Injection Well | No Violations | The dike has been pumped off and is free of fluid .The dike for the production tanks has also been pumped off and is free of fluid. The injection well is not in operation . |
0661700628 | 2015-07-30 | Salt Water Injection Well | No Violations | Inspection on this day indicated that injection pump was not in operation and it was noted that 1/4 valve on tubing head is in need of replacement and owner stated that he would replace valve later today. |
0664226376 | 2010-06-09 | Salt Water Injection Well | No Violations | Well is not in operation. Dike is empty of fluid , liner has been torn on the outer apron and may need repaired if it continures to rip. |
0754398896 | 2008-05-19 | Salt Water Injection Well | No Violations | Check on clean up and found oil spill and brine line cleaned up and repaired.The dike is still flooded and lower left corner has started to drop.Talk to Mark JR and he said dike to be pumped off today and repair made to corner. |
0768121421 | 2011-06-03 | Salt Water Injection Well | No Violations | |
0800696476 | 2012-02-27 | Salt Water Injection Well | No Violations | I had a call from Mark Clark, who wanted to meet with me on site today to go over future clean up and repairs. We went over possible updates to this facility. Mark said he will repair the dike and liner. The liner is torn and will most likely need replaced when updates are made. The front of the dike is slumping because they used a mix of clay and sand to make up the dike walls. I advised that sand should not have been used and that topsoil and clay would have kept the dike from needing repairs now. Mark said he intends to pull and replace the tanks and redo the pad and dike when weather conditions improve. |
0820213871 | 2008-10-21 | Salt Water Injection Well | No Violations | New liner has left corner below pumphouse which appears to have sunk and is now very low.It will need filled in under liner and then the corner shoved up.There are no leaks at this time from under the liner. |
0827480422 | 2003-02-14 | Salt Water Injection Well | No Violations | |
0856479832 | 2010-02-03 | Salt Water Injection Well | No Violations | Pressure test injection line from the pump to the well.Test line to 800 psi and test passed. |
0859059203 | 2014-01-06 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection and I contacted owner and requested that they have positive pressure applied to annulus of tubing. |
0866270377 | 2007-07-24 | Salt Water Injection Well | No Violations | Check Barrel counter and found that it is still not operating .The area around the well has been turned over and should have vegetation soon .Could not get gauge in well to test today .Met with Mark Clark and advise that repairs need to be done on the valve so gauge can be installed . |
0868907521 | 2007-11-09 | Salt Water Injection Well | No Violations | Barrel counter is locked. |
0875216615 | 2012-02-01 | Salt Water Injection Well | No Violations | The pump was not operating during this inspection. The dike has issues with the front wall wanting to sag. It is low enough to fail SPCC requirements if there is more than 8 to 10 inches of fluid inside the dike. During my last several inspections I have found the dike empty. The liner will need repaired or replaced if dike wall is repaired to proper height. |
0899599439 | 2012-12-09 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection and it was noted that owner has not applied stone on pit liner as requested on previous inspection it will help prevent liner from rotting due to exposure to sunlight.
Note: Fresh water needs to be removed from dike area as soon as possible. |
0901374467 | 2009-12-10 | Salt Water Injection Well | Violations Noted | Met Mark Clark on site to test injection line and test failed 4 tests. Tests failed within 2 minutes from 500 psi .Advise Mark to repair lines and call me .He has operation shut down for now and will call to schedule line repairs. |
0906440777 | 2009-09-10 | Salt Water Injection Well | Violations Noted | Dike is full and well in not in operation .Contact Mark Clark and advise pump dike off .Also the peat sorb needs removed and the dike for the production side is full and needs pumped off as well. Well is not in operation. |
0939879655 | 2008-08-18 | Salt Water Injection Well | Violations Noted | Check on dike, found it flooded still, also what appears to be brine leaking out from under the dike.The left corner is sagging and will need some fill dirt pushed up to repair corner.Contact Mark Clark and he is to have pump truck out to pump dike out and repair liner and corner. |
0962807505 | 2007-01-22 | Salt Water Injection Well | No Violations | |
0980252102 | 2006-08-16 | Salt Water Injection Well | No Violations | Clean up is all but complete , well and tank area has been cleaned up .There is a line and assembly for the flowmeter but it has yet to be reconnected . |
0981086853 | 2015-11-25 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection. |
0984682564 | 2011-03-29 | Salt Water Injection Well | No Violations | Dike is empty . |
0996075581 | 2012-07-19 | Salt Water Injection Well | No Violations | The dike was to be improved and repaired when the weather permitted. Dry weather is here and no work has been done. The inside of the dike is dry during this inspection. |
0999254712 | 2006-12-05 | Salt Water Injection Well | No Violations | The lines from the sump have been redone so that they are pumping back into the tanks .Clean up continues both inside the dike and outside .The material outside the dike has been excavated and the oil hauled to a landfill .The secound spill which was in the next tank battery for the production wells has been cleaned up as well . |
1017485834 | 2009-02-26 | Salt Water Injection Well | No Violations | Dike is full of fluid and will need pumped off. Contact Mark Clark and advise that dike needs to remain fluid free. He also advised that it has been shut down because pump needs repaired .He said that he will have a water truck in to lower dike level soon . |
1028759653 | 2007-05-01 | Salt Water Injection Well | No Violations | Pump house is flooded and covered with oil floating on the top of the brine .Could not check barrel counter due to fear of electrical shock . |
1041529660 | 2002-12-31 | Salt Water Injection Well | No Violations | Could not find flow meter in new pumphouse . Will contact Mark Clark to inquire . |
1050066161 | 2008-05-20 | Salt Water Injection Well | Violations Noted | Dike has been pumped off and appears the corner is ok but not really fixed but will be good as long as level remains low inside dike.The tanks on the production side now need cleaned up.Advise Inspector Grimm of problem and he said it was ok for me to go |
1095426304 | 2004-09-03 | Salt Water Injection Well | Violations Noted | During my inspection I found that the flow meter still has not been installed. I met with Mark Clark and advised him that his time was up and he had to install a flow meter .I also advised that if it was not installed on my next inspection that I would se |
1097452912 | 2004-12-22 | Salt Water Injection Well | No Violations | No flow meter .Talk to Mark Clark and he advised that it would be on this week. |
1114214867 | 2007-10-24 | Salt Water Injection Well | No Violations | Pumphouse has been locked up and could not read barrel counter. |
114943271 | 2020-3-2 0:00:0 | SW | No Violations | |
1156169645 | 2006-08-01 | Salt Water Injection Well | No Violations | Check on progress of clean up which needed done around the entire facility .The oil around the sump dike has been mostly cleaned up .The oil which was near the old pumphouse has been cleaned up.The area below the pump and to the left toward the sump pond still need some clean up.The flowmeter has been installed but now needs to be programed to monitor . |
1157862465 | 2012-01-19 | Salt Water Injection Well | No Violations | The contaminated soil around facility has been removed. The area inside of the dike has been pumped off and is free of fluid at this time. The liner has been adjusted some, with dirt placed under it in places. There are tears at the top of the liner that need repaired before there is a loss of integrity. I could not check either the injection side or the annulus because both valves were frozen and I could not get them open. |
1157977618 | 2004-12-27 | Salt Water Injection Well | No Violations | Check to see if flow meter has been installed and found that it has not. Fell on broken steps next to pumphouse.The steps are broken and when I tried to step out of the dike I fell and may have broken my leg? |
1158597756 | 2006-08-11 | Salt Water Injection Well | No Violations | The clean up for this facility is ablut 3/4 complete .The area to the left of the pumphouse has not been completed .There is oil and contaminated soil around the sump and the ditch that supplies it .There is not an operating flowmeter as of this inspection . |
1179952965 | 2016-11-07 | Salt Water Injection Well | No Violations | Injection pump was in operation today and I called well owner Mark Clark and requested that he apply positive pressure to annulus of tubing he stated that we would do mini test later this week he will call and confirm time and date. |
1184843852 | 2009-09-24 | Salt Water Injection Well | No Violations | Well not in operation. Dike level is good. |
1185984112 | 2006-11-02 | Salt Water Injection Well | No Violations | No flowmeter hooked up yet .Operator has said he would hook it up . |
1211850759 | 2007-09-13 | Salt Water Injection Well | No Violations | Violations are corrected. |
1213231040 | 2006-09-06 | Salt Water Injection Well | No Violations | The clean up of this facility is complete .There is no control head for the flow meter .Everything else is on line but it still does not work . |
1231275810 | 2008-12-05 | Salt Water Injection Well | No Violations | |
1239i76 | 2001-11-1 0:00: | SW | No Violations | 1.20 |
1266502906 | 2010-02-17 | Salt Water Injection Well | No Violations | The well does not appear to be in production.The dike is full of snow. |
1301505827 | 2011-02-28 | Salt Water Injection Well | No Violations | Check this well today as part of a field training with the new Inspector Shawn Murphy. Dike is empty and well does not appear to be in operation. |
1305507629 | 2005-09-01 | Salt Water Injection Well | No Violations | Check to see if flow meter has been installed and found that it has not. |
1308190512 | 2011-08-03 | Salt Water Injection Well | No Violations | ID corrected. Pump back in operation. Clean up around dike complete. |
1315352068 | 2019-04-14 | Surface Facility Construction | No Violations | Inspection today revealed that injection pump was in operation during my inspection. |
1319628502 | 2011-10-25 | Salt Water Injection Well | No Violations | Met again with crew on clean up. Found that there has been no clean up done since 7/26/2011. There is a backhoe on site but was advised clean up would begin soon. Issued written notice and also contacted Mark Clark. Clean up is to start 10/26/2011 |
1320336889 | 2011-10-25 | Salt Water Injection Well | Violations Noted | Check tank battery to see if any clean up of the production tanks has been done. Found crew on site but no work has been started since my last inspection. Issue written notice and send it out to cover verbal notice I issued 10/13/2011. |
1320954773 | 2011-11-01 | Salt Water Injection Well | No Violations | Clean up on the production side appears almost done but they have not started on the injection side clean up. |
1332156825 | 2012-02-21 | Salt Water Injection Well | No Violations | During my inspection today, I found the tank battery dike is mostly empty and the well not in operation. |
1346634042 | 2009-11-23 | Salt Water Injection Well | No Violations | Dike is mostly free of fluid. |
1359651030 | 2007-07-03 | Salt Water Injection Well | No Violations | FOLLOW UP TO NOV # 2119197348 Found that the barrel counter has been disconnected and is not operating as required by permit .Later I found that the well was operating over pressure and that there was clean up needed around the well head .The area around |
1367270121 | 2013-04-29 | Salt Water Injection Well | No Violations | Received call from well operator stating that production casing has lost integrity and he will submit repair plan to UIC section in Central Office, told him to contact local UIC inspector when plans were finalized and service rig became available to work on well. |
1370784960 | 2013-06-06 | Salt Water Injection Well | No Violations | Bishop Well Service on site trying to repair casing but there was no activity today at well site. |
1370905124 | 2013-06-07 | Salt Water Injection Well | No Violations | Omega Cementing pumped 200 sacks cement down 4.5 casing in hopes of sealing up casing, Bishop Well Service will drill out excess cement in the near future and once that stage is complete we will again try to pressure test casing to ensure we have good integrity. |
1375055208 | 2013-07-25 | Salt Water Injection Well | No Violations | On site to pressure test casing after Bishop Well Service drilled out cement from inside of casing after recent squeeze job we pressured up to 725 psi and monitored pressure for 15 minutes and well loss 60 psi and test failed so owner is planning on performing another cement job tomorrow and attempt to squeeze cement into zone where we are losing pressure at. |
1375108268 | 2013-07-26 | Salt Water Injection Well | No Violations | On site to witness squeeze job on suspected leak in casing, Omega Cementing pumped 15 sacks cement through tubing and rig crew pulled tubing and then Omega pressured up to 700 psi and we monitored pressure falloff and left pressure on well they will drill out cement on Monday 7/29/13 and then we will retest casing for integrity. |
1375388306 | 2013-08-01 | Salt Water Injection Well | No Violations | On site to witness casing integrity testing Bishop Well Service used there mud pump to apply pressure to casing they pumped 725# of fluid pressure and we monitored pressure too check integrity of production casing ,pressure fell off to 400# in 3 minutes and was still falling when we shut 2 valve and called company rep requesting what there next step could possibly be. |
1376512806 | 2013-08-13 | Salt Water Injection Well | No Violations | On site to witness Bishop Well Service run 2.875 in hole and cement it back to ground level, Omega cementing pumped 45 sacks of Class A cement and they had approximately 1 bbl of good cement returns and it stayed up good at surface. |
1376570045 | 2013-08-15 | Salt Water Injection Well | No Violations | On site to witness running of new 1.5 tubing and new Parmaco packer into SWIW and pump fresh water and inhibitor to pressure test annulus.
Packer set @840 and set under tension with 6 K and there is a 15 anchor joint below packer and Omega Cementing pumped 3 barrel of fresh water and inhibitor and we pressure tested annulus with 780 psi with no decline in pressure. |
1378898525 | 2013-09-11 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and site of recent work over has been seeded and mulched and vegetation has begun to grow. |
1388285147 | 2003-03-11 | Salt Water Injection Well | Violations Noted | The requirements of the permit are for a flowmeter to be used to monitor barrels per day amounts . The meter has been removed and I advised Mark Clark that he must replace meter as soon as possilble . He said that he would try and locate one . 2 |
1390315933 | 2011-10-13 | Salt Water Injection Well | No Violations | FOLLOW UP TO NOV # 471432932 Met with well crew on site and went over leaks and spills. Also went over what needs cleaned up and the repairs to be made. The production tanks need to be removed from the dike and clean up of all old oil and brine completed |
1396516122 | 2004-03-17 | Salt Water Injection Well | No Violations | Injection pressure-650 annulus pressure-0 |
1397558288 | 2010-11-23 | Salt Water Injection Well | No Violations | |
13975987 | 2002-2-15 0:00: | SW | No Violations | 1.20 |
1412224023 | 2007-11-09 | Salt Water Injection Well | No Violations | Barrel counter is locked |
1437170432 | 2007-12-04 | Salt Water Injection Well | No Violations | Found that box to the barrel counter is locked.Contact Mark Clark and he gave me the combo. Try it on the nect inspection. |
1443705798 | 2017-07-25 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and I called well owner Mark Clark and discussed dike work needed at the site to be in compliance with SPCC rules he stated that within the next two weeks he would have dike work completed and he stated also that he is planning on changing out flowline to wellhead I told him that a pressure test would be required once line is replaced. |
1463403355 | 2011-03-16 | Salt Water Injection Well | No Violations | Found well in operation , gauge broke while checking pressure. Need to recheck with new gauge. |
1467257015 | 2011-07-26 | Salt Water Injection Well | No Violations | FOLLOW UP TO NOV # -1640707720 Met on-site with Mark Clark. Issued Compliance Notice to post correct ID and to clean up around back and in front of dike for injection well. Also addressed oil spill in the adjoining dike used for production. Mark is to p |
1479152898 | 2016-11-14 | Salt Water Injection Well | No Violations | On site to witness MIT testing of said well they applied 780 psi and we monitored pressure for 15 minutes with no decline.
TEST PASSED. |
1483204035 | 2006-12-04 | Salt Water Injection Well | Violations Noted | Had tip that a oil spill had occurred at this site .I arrived and found that there had been two spills and that there was oil inside and outside the dike .The oil and brine inside the dike are being pumped out onto the ground .Collect photos and return to New Phila office and pick up samle bottles and return to site .Met Mark Clark on site and went over clean up which needed to begin now .Had Mark disconnect the sump lines which are still pumping brine outside the dike . |
1484459087 | 2013-08-12 | Salt Water Injection Well | No Violations | On site to witness Bishop Well Service run 850 of good used 2.875 in well and they will cement it back to 0 tomorrow morning. |
1485226404 | 2015-10-19 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not running today and owner is putting plan together to rework dike area. |
1493447201 | 2017-04-27 | Salt Water Injection Well | No Violations | Inpection revealed that injection pump was in operation on this day of my inspection. |
1496054432 | 2016-10-21 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was in operation and owner is still planning on correcting dike height to allow for volume in the event of tank failure. |
1501157587 | 2016-08-23 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection.
Note: Dike work still needs to be completed at site. |
1527453881 | 2014-02-24 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection.
Note: Stopped at company office and requested that they has positive pressure applied to annulus of tubing to ensure that they have casing integrity. |
1538504595 | 2005-02-14 | Salt Water Injection Well | No Violations | Met with Mark Clark and advised that a flowmeter had to be installed or I would request a Chiefs order.He said that he had one purchased that it was in the mail and that when it got here he would install it. |
1542997480 | 2003-11-04 | Salt Water Injection Well | No Violations | Check this well with Inspector Grimm.Found that flow meter is not connected and Met with Mark Clark and advised that meter needs to be installed. Also advised on clean up needed at production tanks on other side of facility. He said that he would clean up area soon and install flow line when he found one . I advised that he look around and see if he could find a used one. |
1543359282 | 2016-01-26 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today.
Note: Owner still needs to complete dike improvements. |
1575383640 | 2014-11-25 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and it was noted that owner has placed a 500 bbl tank near current facility and I checked it and it was empty on this day of my inspection. |
1593278957 | 2014-06-04 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today, |
1612553324 | 2009-10-30 | Salt Water Injection Well | No Violations | Check on operating status and found that well is not in operation.Dike is free of fluid |
1640707720 | 2011-07-26 | Salt Water Injection Well | Violations Noted | Met on-site with Mark Clark. Issued Compliance Notice to post correct ID and to clean up around back and in front of dike for injection well. Also addressed oil spill in the adjoining dike used for production. Mark is to post ID for both. He said they will remove the tanks from the production dike in order to completely clean up the old and new oil and brine inside the dike. Then clean up around the back of the tank battery and infront of the tanks for the injection well. |
1642237382 | 2004-01-30 | Salt Water Injection Well | No Violations | Injection pressure---280 Annulus pressure 0- Spoke with Mark Clark and advised again on installing a flow meter as part of his permit conditions.He said that he was keeping track of his water on paper and felt that he did not need a flow meter. I advised him that he did need a flow meter because he could not show a haulers record and he would have no other outside source to verify the amount of brine that he was disposing. |
1652692608 | 2007-08-13 | Salt Water Injection Well | No Violations | Area inside the pumphouse is flooded again so barrel counter could not be checked. |
1659854007 | 2005-08-19 | Salt Water Injection Well | No Violations | Check to see if flow meter has been installed and advised that one was installed and that it failed and was returned .Met with Mark Clark and he advised that one was ordered and it would be here Tues and installed by Weds. |
1677296828 | 2007-09-13 | Salt Water Injection Well | No Violations | Barrel counter remains working .The pressure is within limits. |
1688098130 | 2017-11-14 | Salt Water Injection Well | No Violations | Inspection reveled that injection pump was not in operation during my inspection. |
1690359665 | 2014-10-06 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection. |
1690366222 | 2012-06-15 | Salt Water Injection Well | No Violations | The inside of the dike is dry at this time. The operator has promised to repair the dike and update some of this facility and wanted to wait until it is dry to complete repairs. |
1703907846 | 2012-10-03 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation today.
Note: Water build up in dike area and liner around dike needs to be covered with dirt or stone to help prevent decay due to exposure to sunlight. |
1721693771 | 2012-08-15 | Salt Water Injection Well | No Violations | Dike is dry during this inspection. |
1764682206 | 2007-07-25 | Salt Water Injection Well | No Violations | No working barrel counter at this inspection .Violation has not been corrected. |
1781496097 | 2017-06-01 | Salt Water Injection Well | No Violations | Inspection today revealed that injection pump was in operation during my inspection. |
1787178034 | 2013-03-04 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection.
Note: Exposed portion of pit liner in tank area still needs to be covered with stone to help prevent decay due to exposure to sunlight. |
18076035 | 2002-3-25 0:00: | SW | No Violations | 1.20 |
1814978144 | 2009-04-13 | Salt Water Injection Well | No Violations | This well has not been in operation since last fall .The dike is half full . |
182816782 | 2009-6-17 0:00: | SW | No Violations | 1.00 |
1843906622 | 2006-03-16 | Salt Water Injection Well | No Violations | Flowmeter still not programed and is not in operation. |
1845051992 | 2003-03-11 | Salt Water Injection Well | Violations Noted | FOLLOW UP TO NOV # 1388285147 The requirements of the permit are for a flowmeter to be used to monitor barrels per day amounts . The meter has been removed and I advised Mark Clark that he must replace meter as soon as possilble . He said that he would |
1849063663 | 2008-01-09 | Salt Water Injection Well | No Violations | Flooded inside the dike area and oil and brine are on top of the dike surface.The pump is unconnected and is not in operation.Box for the barrel counter is locked. |
1862711242 | 2015-03-03 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation today and it was noted that there was a 500 bbl tank parked at the facility and it was empty and does not appear to being used at this time. |
1873354065 | 2008-02-20 | Salt Water Injection Well | No Violations | Door locked on barrel counter.Well not in operation due to cold and or parts for the pump. |
1886849670 | 2005-07-07 | Salt Water Injection Well | No Violations | Check on status of flow meter and found that there is still no meter.Met with Mark Clark and he said that it has been ordered and that as soon as it arrives it will be installed. |
1903028564 | 2018-01-24 | Salt Water Injection Well | No Violations | Inspection today indicated that injection pump was in operation during my inspection.
Note: Still waiting on owner to bring dike up to current standards. |
1903398622 | 2007-04-18 | Salt Water Injection Well | No Violations | Could not check the barrel counter today because the pumphouse is flooded and so is the dike .There is a liner in place to contain all of the fluid but I am not sure of the electrical . |
1903697435 | 2013-10-17 | Salt Water Injection Well | No Violations | Inspection revealed that well was not in operation during my inspection.
Note: 3-210 bbl tanks at site used for brine storage. |
1910542869 | 2013-04-10 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection and it was noted that water in dike area needs to be removed to allow for volume in the event of tank failure and also exposed portion of pit liner in tank area needs to be covered with stone and positive pressure needs to be applied to annulus of tubing after valves are replaced on tubing head. |
1928477715 | 2013-04-16 | Administrative Inspection | No Violations | Talked to Mark Clark concerning applying positive pressure to annulus of tubing to confirm that they have casing integrity and he quoted that he would have pressure applied by mid May. |
1946671777 | 2005-09-07 | Salt Water Injection Well | No Violations | Check well to see if they have installed a flow meter and they have not.Met with Mark Clark and he has the flow meter, he just has not installed it. |
1947189785 | 2010-10-15 | Salt Water Injection Well | No Violations | Dike is dry of fluid, well does not appear to be in operation. |
1963508994 | 2010-01-22 | Salt Water Injection Well | No Violations | Well is not in operation .Dike has some fluid in it but is not bad. The pump is connected but does not appear to have been run for a while. |
1982788968 | 2006-10-30 | Salt Water Injection Well | No Violations | Check to see if flowmeter had been connected and found that it has not .Line connected but no meter . |
1998071349 | 2008-09-08 | Salt Water Injection Well | No Violations | Dike has some fluid in it , not enough to make it leak.Now it will need checked again to make sure that there is not a leak. |
2007714522 | 2015-09-24 | Salt Water Injection Well | No Violations | Inspection on this day indicated that injection pump was not in operation and we measured dike for compliance with connected volumes and we called owner telling him that dike height will need to be adjusted to become into compliance. |
2043062673 | 2018-09-17 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was in operation during my inspection.
Note: Owner is preparing to install extension to containment area as requested in previous inspections. |
2049874970 | 2013-07-31 | Salt Water Injection Well | No Violations | On site to witness third squeeze job on production casing Omega Cementing pumped 35 sacks Class A cement through tubing and pulled tubing from well and then applied 750 psi to casing too force cement into suspected hole in casing and they left well shut in and they plan on pressure testing the top 200 of casing in the morning. |
2050463951 | 2011-10-26 | Salt Water Injection Well | No Violations | Met with clean up crew and witnessed clean up of production dike. All of the contaminate soil is to be removed and taken to a landfill. Clean up should be done in a few days. Did not check well pressure. |
2070568454 | 2014-04-16 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and I called company rep and requested that they have fresh water removed from dike area too allow for volume in the event of a major spill. |
2083311480 | 2006-02-10 | Salt Water Injection Well | No Violations | NO flow meter connected. |
2119197348 | 2007-07-03 | Salt Water Injection Well | Violations Noted | Found that the barrel counter has been disconnected and is not operating as required by permit .Later I found that the well was operating over pressure and that there was clean up needed around the well head .The area around the well needs to be limed graded and seeded along with mulch . |
2124198787 | 2014-08-12 | Salt Water Injection Well | No Violations | Inspection revealed that injection pump was not in operation during my inspection and it was noted that owner has replaced 1/4valve on annulus of tubing since my last inspection. |
212490542 | 2010-1-25 0:00: | SW | No Violations | 0.50 |
215171228 | 2004-9-28 0:00: | SW | No Violations | 1.50 |
24254297 | 2009-7-28 0:00: | SW | No Violations | 1.50 |
246266890 | 2018-3-1 0:00:0 | SW | No Violations | |
275799393 | 2009-6-1 0:00:0 | SW | No Violations | 1.50 |
276756343 | 2010-3-12 0:00: | SW | No Violations | 1.50 |
288768423 | 2006-2-6 0:00:0 | SW | No Violations | 1.50 |
30919163 | 2016-2-1 0:00:0 | SW | No Violations | |
32376125 | 2002-7-8 0:00:0 | SW | No Violations | 0.70 |
32876130 | 2002-7-2 0:00:0 | SW | No Violations | 1.20 |
3351226 | 2009-4-17 0:00: | PW | No Violations | 3.00 |
344385434 | 2007-8-14 0:00: | SW | No Violations | 1.00 |
3855199 | 2020-3-5 0:00:0 | SW | No Violations | |
38776006 | 2002-8-20 0:00: | SW | No Violations | 1.20 |
410821013 | 2008-5-16 0:00: | SW | No Violations | 3.50 |
423019147 | 2008-9-4 0:00:0 | SW | No Violations | 1.50 |
432841398 | 2010-4-13 0:00: | SW | No Violations | 1.50 |
435047237 | 2018-6-1 0:00:0 | SW | No Violations | |
437381003 | 2005-8-4 0:00:0 | SW | No Violations | 1.50 |
460 | 2002-10-16 0:00 | SW | No Violations | 1.20 |
471432932 | 2011-10-13 0:00 | SW | No Violations | 1.50 |
480767146 | 2003-7-10 0:00: | SW | No Violations | 1.20 |
480947385 | 2009-4-30 0:00: | SW | No Violations | 2.00 |
500221194 | 2013-7-24 0:00: | SW | No Violations | |
518195341 | 2003-9-15 0:00: | SW | No Violations | 1.20 |
566963086 | 2006-7-12 0:00: | SW | No Violations | 2.00 |
583338642 | 2006-7-21 0:00: | SW | No Violations | 2.50 |
612957075 | 2008-4-18 0:00: | SW | No Violations | 1.50 |
654210810 | 2008-6-19 0:00: | SW | No Violations | 1.50 |
74392376 | 2006-7-18 0:00: | SW | No Violations | 1.00 |
754398896 | 2008-5-19 0:00: | SW | No Violations | 1.50 |
7675910 | SW | No Violations | 1.20 | |
768121421 | 2011-6-3 0:00:0 | SW | No Violations | 1.50 |
820213871 | 2008-10-21 0:00 | SW | No Violations | 1.50 |
827480422 | 2003-2-14 0:00: | SW | No Violations | 1.50 |
856479832 | 2010-2-3 0:00:0 | SW | No Violations | 2.50 |
866270377 | 2007-7-24 0:00: | SW | No Violations | 1.50 |
868907521 | 2007-11-9 0:00: | SW | No Violations | |
899599439 | 2012-12-9 0:00: | SW | No Violations | |
906440777 | 2009-9-10 0:00: | SW | No Violations | 1.50 |
939879655 | 2008-8-18 0:00: | SW | No Violations | 2.20 |
996075581 | 2012-7-19 0:00: | SW | No Violations | 1.50 |
PL2647 | PL | No Violations | ||
UIC1482 | 1993-10-14 0:00 | SW | No Violations | |
UIC1483 | 1993-10-14 0:00 | SW | No Violations | |
UIC214 | 1987-6-10 0:00: | SW | No Violations | |
UIC215 | 1987-6-10 0:00: | SW | No Violations | |
UIC216 | 1987-6-10 0:00: | SW | No Violations | |
UIC256 | 1987-8-3 0:00:0 | SW | No Violations | |
UIC257 | 1987-8-3 0:00:0 | SW | No Violations | |
UIC810 | 1989-11-28 0:00 | SW | No Violations | |
UIC887 | 1990-4-20 0:00: | SW | No Violations | |
UIC888 | 1990-4-20 0:00: | SW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0003351226 | US-OH-123508 | 2009-09-01 | Well operation causing pollution and contamination | |
0003351226 | US-OH-123509 | 2009-09-01 | Failure to keep dike or pit free of brine or other wastes | |
0035601521 | US-OH-123744 | 2009-01-20 | Pits not liquid tight/Improper construction or use | |
0217730419 | US-OH-122157 | 2019-04-08 | Failure to report disposal fees | |
0246266890 | US-OH-122507 | 2018-03-27 | 9-3-07(D) | Exceeding maximum allowable injection pressure |
0410821013 | US-OH-124349 | 2008-10-07 | Pollution/Contamination | |
0471432932 | US-OH-125120 | 2011-10-25 | Pollution/Contamination | |
0477855220 | US-OH-125197 | 2008-10-07 | Pollution/Contamination | |
0543430886 | US-OH-125958 | 2008-10-07 | Pollution/Contamination | |
0566963086 | US-OH-126367 | 2006-08-07 | Mechanical failure/contamination | |
0654210810 | US-OH-127411 | 2008-10-08 | Pits not liquid tight/Improper construction or use | |
0901374467 | US-OH-130290 | 2010-01-26 | Violation of injection tubing/fitting requirements | |
0906440777 | US-OH-130346 | 2009-10-07 | Contamination at surface facility (permit before 6-1-82) | |
0939879655 | US-OH-130763 | 2008-10-08 | Pollution/Contamination | |
1050066161 | US-OH-100823 | 2008-10-07 | Pollution/Contamination | |
1095426304 | US-OH-102260 | 2004-09-17 | Failure to monitor pressures/volumes | |
1320336889 | US-OH-109161 | 2011-11-03 | Pollution/Contamination | |
1388285147 | US-OH-111500 | 2003-03-24 | Failure to monitor pressures/volumes | |
1483204035 | US-OH-113755 | 2006-12-19 | Pollution/Contamination | |
1483204035 | US-OH-113756 | 2006-12-19 | Mechanical failure/contamination | |
1640707720 | US-OH-116147 | 2011-09-26 | Pollution/Contamination | |
1845051992 | US-OH-118426 | 2003-03-24 | Failure to monitor pressures/volumes | |
2119197348 | US-OH-121706 | 2007-07-11 | Contamination at surface facility (permit after 6-1-82) | |
2119197348 | US-OH-121707 | 2007-07-11 | Exceeding maximum allowable injection pressure | |
2119197348 | US-OH-121708 | 2007-07-11 | Failure to monitor pressures/volumes |
For data sources see[9]