X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-157-24311

Well Details

Well ID: 34-157-24311
Loading map...
Country: United States
State: Ohio
County: Tuscarawas
Municipality: Clay Township
Operator Name: MAINSPRING LLC
Well Pad ID:
Farm/Lease Name: GARRETT NORA
License Status: Active Injection
License Date: 1985-08-13
Spud Date: 1985-11-09
Spud Drilling Contractor: GREGS DRLG
Final Drill Date: 1985-12-24
Well Total Depth: 975.00 ft
Configuration: Vertical
Latitude: 40.330000
Longitude: -81.450000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1985-08-13 2203 HALTER RALPH P GeoDate 8/13/85
Conversion to Injector 1985-08-13
Salt Water Injection Well 1985-08-13 Issued Date 8/13/85 Expired Date 8/13/86 Acres 0100000 Tool Type CT Proposed Formation BEREA Proposed Depth 00975 Proposed Drill Depth 00975
Storage Well 1985-08-13 Issued Date 8/13/85 Expired Date 8/13/86 Acres 0100000 Tool Type CT Proposed Formation BEREA Proposed Depth 00975 Proposed Drill Depth 00975
Original Spud 1985-10-09 FDT=GRAY
Completed 1985-12-24 FDT=GRAY
Reached Total Depth 1985-12-24 FDT=GRAY
First Injection 1986-01-01 FDT=GRAY
Construction Permit Expires 1986-08-13 FDT=GRAY
Water Analysis 1986-08-15 FDT=GRAY
Completion Report Received 1987-05-05 FDT=GRAY
Change of Owner 1998-06-12 Operator changed from 2203, HALTER RALPH P to 1586, L L P OIL & GAS CORP
Annulus Pressure Monitoring Approved 1999-02-26 FDT=GRAY
Last Compliance Report 2013-08-19 FDT=GRAY
Record Last Modified 2017-10-19 FDT=GRAY

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-08 870 960 0
870 960 0
870 960 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 NONE

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2005 LLP GAS AND OIL CORPORATION 0.00 76.00 365
2006 LLP GAS AND OIL CORPORATION 0.00 0.00 0
2007 LLP GAS AND OIL CORPORATION 0.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2005 LLP GAS AND OIL CORPORATION Brine 0 365
2006 LLP GAS AND OIL CORPORATION Brine 0
2007 LLP GAS AND OIL CORPORATION Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1028759653 2007-5-1 0:00:0 SW No Violations 1.50
-1097452912 2004-12-22 0:00 SW No Violations 1.50
-1114214867 2007-10-24 0:00 SW No Violations 1.00
-1157862465 2012-1-19 0:00: SW No Violations 1.50
-1179952965 2016-11-7 0:00: SW No Violations
-1213231040 2006-9-6 0:00:0 SW No Violations 1.50
-1231275810 2008-12-5 0:00: SW No Violations 1.50
-126334627 2006-9-21 0:00: SW No Violations 1.50
-127933794 2017-10-4 0:00: SW No Violations
-1308190512 2011-8-3 0:00:0 SW No Violations 1.50
-1315352068 2019-4-14 0:00: SC No Violations
-1346634042 2009-11-23 0:00 SW No Violations 1.50
-1359651030 2007-7-3 0:00:0 SW No Violations 2.00
-13857594 2008-4-29 0:00: SW No Violations 1.50
-1390315933 2011-10-13 0:00 SW No Violations 1.50
-1397558288 2010-11-23 0:00 SW No Violations 1.50
-1467257015 2011-7-26 0:00: SW No Violations 2.50
-1484459087 2013-8-12 0:00: SW No Violations
-1485226404 2015-10-19 0:00 SW No Violations
-1496054432 2016-10-21 0:00 SW No Violations
-149654150 2011-5-3 0:00:0 SW No Violations 2.00
-1501157587 2016-8-23 0:00: SW No Violations
-1527453881 2014-2-24 0:00: SW No Violations
-1542997480 2003-11-4 0:00: SW No Violations 1.20
-15685485 2007-12-13 0:00 SW No Violations 1.50
-1638111496 2019-8-5 0:00:0 SW No Violations
-1640707720 2011-7-26 0:00: SW No Violations 2.50
-1642237382 2004-1-30 0:00: SW No Violations 1.20
-1688098130 2017-11-14 0:00 SW No Violations
-1690359665 2014-10-6 0:00: SW No Violations
-1690366222 2012-6-15 0:00: SW No Violations 1.50
-1721693771 2012-8-15 0:00: SW No Violations 1.50
-1764682206 2007-7-25 0:00: SW No Violations 1.00
-1781496097 2017-6-1 0:00:0 SW No Violations
-1787178034 2013-3-4 0:00:0 SW No Violations
-1814978144 2009-4-13 0:00: SW No Violations 0.50
-1843906622 2006-3-16 0:00: SW No Violations 1.50
-1873354065 2008-2-20 0:00: SW No Violations 1.50
-1886849670 2005-7-7 0:00:0 SW No Violations 1.50
-1903028564 2018-1-24 0:00: SW No Violations
-1903697435 2013-10-17 0:00 SW No Violations
-1910542869 2013-4-10 0:00: SW No Violations
-1946671777 2005-9-7 0:00:0 SW No Violations 2.50
-1982788968 2006-10-30 0:00 SW No Violations 1.50
-1998071349 2008-9-8 0:00:0 SW No Violations 1.50
-2070568454 2014-4-16 0:00: SW No Violations
-2083311480 2006-2-10 0:00: SW No Violations 1.50
-217730419 2019-2-11 0:00: SW No Violations
-2203256 2005-3-9 0:00:0 SW No Violations 1.20
-239325582 2006-1-20 0:00: SW No Violations 1.50
-242784464 2003-4-16 0:00: SW No Violations 1.50
-2447178 2018-3-5 0:00:0 SW No Violations
-252847937 2010-6-16 0:00: SW No Violations 1.00
-258523161 2009-1-6 0:00:0 SW No Violations 2.20
-28958460 2007-2-23 0:00: SW No Violations 1.50
-293928808 2019-8-30 0:00: SW No Violations
-35601521 2008-9-3 0:00:0 SW No Violations 2.00
-446612777 2013-6-4 0:00:0 SW No Violations
-477855220 2008-4-14 0:00: SW No Violations 1.50
-489691742 2016-3-10 0:00: SW No Violations
-507036618 2006-1-27 0:00: SW No Violations 1.50
-516149948 2006-5-9 0:00:0 SW No Violations 1.50
-543430886 2008-4-15 0:00: SW No Violations 3.00
-582995211 2018-2-28 0:00: SW No Violations
-588848110 2012-4-11 0:00: SW No Violations 1.50
-590616108 2006-12-6 0:00: SW No Violations 1.00
-648614312 2010-3-31 0:00: SW No Violations 1.50
-652281072 2006-7-25 0:00: SW No Violations 1.50
-659925952 2009-9-17 0:00: SW No Violations 1.50
-661700628 2015-7-30 0:00: SW No Violations
-664226376 2010-6-9 0:00:0 SW No Violations 1.50
-73378877 2017-2-15 0:00: SW No Violations
-800696476 2012-2-27 0:00: SW No Violations 2.50
-859059203 2014-1-6 0:00:0 SW No Violations
-875216615 2012-2-1 0:00:0 SW No Violations 1.50
-901374467 2009-12-10 0:00 SW No Violations 1.50
-962807505 2007-1-22 0:00: SW No Violations 1.50
-980252102 2006-8-16 0:00: SW No Violations 1.50
-981086853 2015-11-25 0:00 SW No Violations
-984682564 2011-3-29 0:00: SW No Violations 1.50
-999254712 2006-12-5 0:00: SW No Violations 3.00
0000000460 2002-10-16 Salt Water Injection Well No Violations
0000PL2647 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0000UIC214 1987-06-10 Salt Water Injection Well No Violations 1509.22 (A)(1)(2)(C)(3)
0000UIC215 1987-06-10 Salt Water Injection Well No Violations 1501:9-3-04(A)
0000UIC216 1987-06-10 Salt Water Injection Well No Violations 15019-3-05 (A)(6)
0000UIC256 1987-08-03 Salt Water Injection Well No Violations 1509.03
0000UIC257 1987-08-03 Salt Water Injection Well No Violations 1509.072
0000UIC810 1989-11-28 Salt Water Injection Well No Violations 1501:9-3-08 (B) Temporary storage
0000UIC887 1990-04-20 Salt Water Injection Well No Violations 1509.22(A) STORAGE & DISPOSAL
0000UIC888 1990-04-20 Salt Water Injection Well No Violations 1509.22(A) PREVENTION AND CONTA
0001239i76 2001-11-01 Salt Water Injection Well No Violations The new tank facility is almost ready to be hooked up. The operator is to call when he is to continue work.
0002203256 2005-03-09 Salt Water Injection Well No Violations Met again with Mark Clark and he said that he send the part back and the replacement was coming to fix his meter.
0002447178 2018-03-05 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation during my inspection and well owner Mark Clark was on site to test Murphy switch to verify that it works properly switch shut down pump at 720 psi which is 5psi below maximum allowable injection pressure.
0003351226 2009-04-17 Production Wells Violations Noted Had anonymous call of oil running over tanks .Arrived and found that the production tanks for the Garret lease have been run over .The inside of the dike is full of oil .The oil is running under the dike and down to the ditch in front of the tanks along the road . Contact Mark Clark and he said he would have somebody there within the hour. I returned and found that the clean up is under way with peat sorb and small pillows collecting the oil. Returned to the New Phila office to shut off the lights and turn off computer , fuel up vehicle .When I returned I found nobody around.The clean up was only done enough to keep it from running out of the dike and now everyone is gone.Contact Inspector Grimm and advise that it was the production side of the injection wells .He advised that if I was there to go ahead and handle clean up and issue NOV.
0007675910 Salt Water Injection Well No Violations The new tank facility is almost ready to be hooked up. The operator is to call when he is to continue work.
000UIC1482 1993-10-14 Salt Water Injection Well No Violations 1501: 9-1-07 POLLUTION
000UIC1483 1993-10-14 Salt Water Injection Well No Violations 1501: 9-3-04 (A) PREVENT CONTAMINATE
0013857594 2008-04-29 Salt Water Injection Well No Violations Check on clean up and found tanks over run with brine and oil.Contact Mark Clark and advise of clean up again.He is to have equipnent there soon.Within days.
0013975987 2002-02-15 Salt Water Injection Well No Violations Met with Mark Clark at the facility and went over changes being made to the tanks and pumphouse.
0015685485 2007-12-13 Salt Water Injection Well No Violations Tried lock combo for the barrel counter and it did not work .
0018076035 2002-03-25 Salt Water Injection Well No Violations Met with Mark Clark on plugging wells for State Orphan program.
0024254297 2009-07-28 Salt Water Injection Well No Violations Dike is not over full and well is not in operation.Review production tanks and clean up with Inspector Grimm.
0028958460 2007-02-23 Salt Water Injection Well No Violations Too much ice on steps to check barrel counter .
0030919163 2016-02-01 Salt Water Injection Well No Violations Injection pump was not in operation during my inspection.
0032376125 2002-07-08 Salt Water Injection Well No Violations Return to check this well to make sure that there was not a spill after lines have been relocated. Check this well with Inspector Grimm.Pressure not checked during this inspection .
0032876130 2002-07-02 Salt Water Injection Well No Violations Talk with Mark Clark and he advised that he will be changing lines and may have alittle oil to clean up around bottom of pumphouse. Check this well with Inspector Grimm.
0035601521 2008-09-03 Salt Water Injection Well Violations Noted Dike is full and will need pumped off ASAP. Dike also appears to be leaking under liner .Conact Mark Clark and advise that dike is full and about to over flow.Talk about possilbe leak in liner also.
0038776006 2002-08-20 Salt Water Injection Well No Violations
0073378877 2017-02-15 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that new plumbing has been installed on injection pump.
0074392376 2006-07-18 Salt Water Injection Well No Violations Review site for clean up and found that there is very little done.Review site with Inspector Grimm
0126334627 2006-09-21 Salt Water Injection Well No Violations Still no flow meter .Left message for Mark Clark to install meter controll so that monitoring can begin .
0127933794 2017-10-04 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation during my inspection.
0149654150 2011-05-03 Salt Water Injection Well No Violations Dike is empty of fluid.
0182816782 2009-06-17 Salt Water Injection Well No Violations The inside of the dike is about 1/4 of the way filled. Contact operator Mark Clark and advise that dike is filling up. Also advise that more peat sorb is needed in the next dike over for the production tanks .
0212490542 2010-01-25 Salt Water Injection Well No Violations Just check dike today because we have had a ton of rain the last few days.Found that the dike has some fluid in it but it is not too high ,could be pumped down now that it is not frozen.Well not in operation
0215171228 2004-09-28 Salt Water Injection Well No Violations No flow meter connected to system at this time.Talk again to Mark Clark and advised again that a flowmeter was part of his permit conditions and would need to be installed ASAP.
0217730419 2019-02-11 Salt Water Injection Well Violations Noted The Division has not received the 1st, 2nd, 3rd, & 4th quarter brine disposal fees for 2018. Please forward disposal fees and sheets to the Division by 3/12/2019.
0239325582 2006-01-20 Salt Water Injection Well No Violations Met with Mark Clark and found that flowmeter is on but is not working correctly and needs to be programed.He is to have somebody do that this week.
0242784464 2003-04-16 Salt Water Injection Well No Violations Talk with Mark Clark on placing a meter back on injection side to monitor barrels . Mark told me he has one ordered and as soon as it arrives he will install it .
0246266890 2018-03-01 Salt Water Injection Well Violations Noted The Division received annual report form 204. Review of the form 204 revealed an exceedance of the maximum allowable injection pressure. The injection pressure shall be reduced and the auto shut down switch shall be adjusted to the maximum allowable injection pressure. A follow-up inspection will be conducted.
0252847937 2010-06-16 Salt Water Injection Well No Violations Check dike level and found it dry - well not in operation
0258523161 2009-01-06 Salt Water Injection Well No Violations Had tip that I needed to check out this well again .Found everything frozen inside pumphouse.Doors and windows are open and no heat on .Pump appears to have broken due to the cold .Dike is at 1/2 full.There is not enough room left inside the dike for a tank failure.Contact Mark Clark and advise on what I found .Did not get hold of him?
0275799393 2009-06-01 Salt Water Injection Well No Violations Check dike for fluid level and found that dike has been pumped free of fluid. Well does not appear to be in operation . The production tanks next to this facility have been run over. There is peat sorbs down inside the dike . The inside of the dike should be cleaned up after the peat sorbs has collected as much of the oil as it can . Contact Inspector Grimm and advise and he said for me to handle the clean up when I return for Injection inspection .
0276756343 2010-03-12 Salt Water Injection Well No Violations No injection at this inspection.Dike is full and needs pumped off.
0288768423 2006-02-06 Salt Water Injection Well No Violations Flowmeter is not currently connected.Still has a programming problem.
0344385434 2007-08-14 Salt Water Injection Well No Violations Area still flooded and barrel counter could not be checked.Contacted Mark Clark and he said that barrel counter will be fixed Wedsday 8/15/2007
0410821013 2008-05-16 Salt Water Injection Well Violations Noted Whle checking dike and clean up around dike I found another leak on the same side as the dike.There are now two clean up areas needed along with the dike area and below the pumphouse.Contacted Mark Clark and then met with clean up crew on site .Mark is to
0423019147 2008-09-04 Salt Water Injection Well No Violations Dike pumped off .The area in front of dike has been excavated and removed and is now dry, but so is dike.Need to check again after there is fluid inside of dike again.Well not operating at this time.
0432841398 2010-04-13 Salt Water Injection Well No Violations Well does not appear to be in operation. Dike is empty of fluid
0435047237 2018-06-01 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.
0437381003 2005-08-04 Salt Water Injection Well No Violations Check to see if flowmeter has been installed and found that it has not.Try and contact Mark Clark to re-issue NOV
0446612777 2013-06-04 Salt Water Injection Well No Violations Omega Cementing on site to set a 100 cement plug on top of bridge plug set@852 owner will attempt to squeeze cement into casing hole later this week.
0471432932 2011-10-13 Salt Water Injection Well Violations Noted Met with well crew on site and went over leaks and spills. Also went over what needs cleaned up and the repairs to be made. The production tanks need to be removed from the dike and clean up of all old oil and brine completed. The brine on the back side of the injection well dike, as well as the area behind the pumphouse over to the retaining pond needs cleaned up. The dike liner is torn and needs repaired or replaced. Well pressure was not checked.
0477855220 2008-04-14 Salt Water Injection Well Violations Noted Found mess around tank battery and pumphouse is locked area is under water and covered in oil .It is not safe to check barrel counter with brine and this electrical set up.
0480767146 2003-07-10 Salt Water Injection Well No Violations Flow meter is back ordered.
0480947385 2009-04-30 Salt Water Injection Well No Violations Check on clean up and found that there is peat sorb on top of all of the oil.There has been no other clean up done at this time. Well is not in operation and maybe the entire field is shut in.
0489691742 2016-03-10 Salt Water Injection Well No Violations Injection pump not in operation during my inspection.
0500221194 2013-07-24 Salt Water Injection Well No Violations Bishop Well Service on site rigging up preparing to drill cement out from inside of casing after recent squeeze job on casing
0507036618 2006-01-27 Salt Water Injection Well No Violations There has been some progress on the flowmeter ,but it is still not recording barrels correctly.
0516149948 2006-05-09 Salt Water Injection Well No Violations The pumphouse has a leak and the flowmeter that was hooked up has been removed ?
0518195341 2003-09-15 Salt Water Injection Well No Violations Talked to Mark Clark and he said that the flow meter has been ordered and should be installed on my next regular inspection.
0543430886 2008-04-15 Salt Water Injection Well Violations Noted while checking to see if dike has been pumped off I found an oil leak on the other side of the hill .Contact Mark Clark and advise of leak.Found that dike has not been pumped off.
0566963086 2006-07-12 Salt Water Injection Well Violations Noted I found that the packing was leaking and all of the fluid was bypassing the vault.The pump for the vault was connected to a pipe outside the dike .All of the fluid that was leaking out of the pump packing was being pumped out on the ground .I also found that the old building which holds the oil drums has had a spill ? I have contacted Mark Clark and will meet him on site to review clean up.
0582995211 2018-02-28 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection
0583338642 2006-07-21 Salt Water Injection Well No Violations Met Mark Clark and clean up crew on site and went over everything that needs cleaned up.
0588848110 2012-04-11 Salt Water Injection Well No Violations The inside of the dike is free of fluid. The repairs to the liner and the dike wall have not been completed at this time.
0590616108 2006-12-06 Salt Water Injection Well No Violations The barrel counter has been installed .
0612957075 2008-04-18 Salt Water Injection Well No Violations Check on clean up and dike level.Found no fluid pumped .Dike remains almost full.
0648614312 2010-03-31 Salt Water Injection Well No Violations The well is not in operation.The dike is free of fluid .
0652281072 2006-07-25 Salt Water Injection Well No Violations Check to see if clean up is done and found out that not much has been done.Packing leaking again on the pump.It is not being pumped out on the ground during this inspection.Contact Mark Clark and advise of packing leak.
0654210810 2008-06-19 Salt Water Injection Well Violations Noted The inside of the dike is flooded and there is less than 50 bbls of space left from going over the top of the dike.The left corner is also too low and will need to be pushed up for more containment.
0659925952 2009-09-17 Salt Water Injection Well No Violations The dike has been pumped off and is free of fluid .The dike for the production tanks has also been pumped off and is free of fluid. The injection well is not in operation .
0661700628 2015-07-30 Salt Water Injection Well No Violations Inspection on this day indicated that injection pump was not in operation and it was noted that 1/4 valve on tubing head is in need of replacement and owner stated that he would replace valve later today.
0664226376 2010-06-09 Salt Water Injection Well No Violations Well is not in operation. Dike is empty of fluid , liner has been torn on the outer apron and may need repaired if it continures to rip.
0754398896 2008-05-19 Salt Water Injection Well No Violations Check on clean up and found oil spill and brine line cleaned up and repaired.The dike is still flooded and lower left corner has started to drop.Talk to Mark JR and he said dike to be pumped off today and repair made to corner.
0768121421 2011-06-03 Salt Water Injection Well No Violations
0800696476 2012-02-27 Salt Water Injection Well No Violations I had a call from Mark Clark, who wanted to meet with me on site today to go over future clean up and repairs. We went over possible updates to this facility. Mark said he will repair the dike and liner. The liner is torn and will most likely need replaced when updates are made. The front of the dike is slumping because they used a mix of clay and sand to make up the dike walls. I advised that sand should not have been used and that topsoil and clay would have kept the dike from needing repairs now. Mark said he intends to pull and replace the tanks and redo the pad and dike when weather conditions improve.
0820213871 2008-10-21 Salt Water Injection Well No Violations New liner has left corner below pumphouse which appears to have sunk and is now very low.It will need filled in under liner and then the corner shoved up.There are no leaks at this time from under the liner.
0827480422 2003-02-14 Salt Water Injection Well No Violations
0856479832 2010-02-03 Salt Water Injection Well No Violations Pressure test injection line from the pump to the well.Test line to 800 psi and test passed.
0859059203 2014-01-06 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and I contacted owner and requested that they have positive pressure applied to annulus of tubing.
0866270377 2007-07-24 Salt Water Injection Well No Violations Check Barrel counter and found that it is still not operating .The area around the well has been turned over and should have vegetation soon .Could not get gauge in well to test today .Met with Mark Clark and advise that repairs need to be done on the valve so gauge can be installed .
0868907521 2007-11-09 Salt Water Injection Well No Violations Barrel counter is locked.
0875216615 2012-02-01 Salt Water Injection Well No Violations The pump was not operating during this inspection. The dike has issues with the front wall wanting to sag. It is low enough to fail SPCC requirements if there is more than 8 to 10 inches of fluid inside the dike. During my last several inspections I have found the dike empty. The liner will need repaired or replaced if dike wall is repaired to proper height.
0899599439 2012-12-09 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that owner has not applied stone on pit liner as requested on previous inspection it will help prevent liner from rotting due to exposure to sunlight.

Note: Fresh water needs to be removed from dike area as soon as possible.

0901374467 2009-12-10 Salt Water Injection Well Violations Noted Met Mark Clark on site to test injection line and test failed 4 tests. Tests failed within 2 minutes from 500 psi .Advise Mark to repair lines and call me .He has operation shut down for now and will call to schedule line repairs.
0906440777 2009-09-10 Salt Water Injection Well Violations Noted Dike is full and well in not in operation .Contact Mark Clark and advise pump dike off .Also the peat sorb needs removed and the dike for the production side is full and needs pumped off as well. Well is not in operation.
0939879655 2008-08-18 Salt Water Injection Well Violations Noted Check on dike, found it flooded still, also what appears to be brine leaking out from under the dike.The left corner is sagging and will need some fill dirt pushed up to repair corner.Contact Mark Clark and he is to have pump truck out to pump dike out and repair liner and corner.
0962807505 2007-01-22 Salt Water Injection Well No Violations
0980252102 2006-08-16 Salt Water Injection Well No Violations Clean up is all but complete , well and tank area has been cleaned up .There is a line and assembly for the flowmeter but it has yet to be reconnected .
0981086853 2015-11-25 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.
0984682564 2011-03-29 Salt Water Injection Well No Violations Dike is empty .
0996075581 2012-07-19 Salt Water Injection Well No Violations The dike was to be improved and repaired when the weather permitted. Dry weather is here and no work has been done. The inside of the dike is dry during this inspection.
0999254712 2006-12-05 Salt Water Injection Well No Violations The lines from the sump have been redone so that they are pumping back into the tanks .Clean up continues both inside the dike and outside .The material outside the dike has been excavated and the oil hauled to a landfill .The secound spill which was in the next tank battery for the production wells has been cleaned up as well .
1017485834 2009-02-26 Salt Water Injection Well No Violations Dike is full of fluid and will need pumped off. Contact Mark Clark and advise that dike needs to remain fluid free. He also advised that it has been shut down because pump needs repaired .He said that he will have a water truck in to lower dike level soon .
1028759653 2007-05-01 Salt Water Injection Well No Violations Pump house is flooded and covered with oil floating on the top of the brine .Could not check barrel counter due to fear of electrical shock .
1041529660 2002-12-31 Salt Water Injection Well No Violations Could not find flow meter in new pumphouse . Will contact Mark Clark to inquire .
1050066161 2008-05-20 Salt Water Injection Well Violations Noted Dike has been pumped off and appears the corner is ok but not really fixed but will be good as long as level remains low inside dike.The tanks on the production side now need cleaned up.Advise Inspector Grimm of problem and he said it was ok for me to go
1095426304 2004-09-03 Salt Water Injection Well Violations Noted During my inspection I found that the flow meter still has not been installed. I met with Mark Clark and advised him that his time was up and he had to install a flow meter .I also advised that if it was not installed on my next inspection that I would se
1097452912 2004-12-22 Salt Water Injection Well No Violations No flow meter .Talk to Mark Clark and he advised that it would be on this week.
1114214867 2007-10-24 Salt Water Injection Well No Violations Pumphouse has been locked up and could not read barrel counter.
114943271 2020-3-2 0:00:0 SW No Violations
1156169645 2006-08-01 Salt Water Injection Well No Violations Check on progress of clean up which needed done around the entire facility .The oil around the sump dike has been mostly cleaned up .The oil which was near the old pumphouse has been cleaned up.The area below the pump and to the left toward the sump pond still need some clean up.The flowmeter has been installed but now needs to be programed to monitor .
1157862465 2012-01-19 Salt Water Injection Well No Violations The contaminated soil around facility has been removed. The area inside of the dike has been pumped off and is free of fluid at this time. The liner has been adjusted some, with dirt placed under it in places. There are tears at the top of the liner that need repaired before there is a loss of integrity. I could not check either the injection side or the annulus because both valves were frozen and I could not get them open.
1157977618 2004-12-27 Salt Water Injection Well No Violations Check to see if flow meter has been installed and found that it has not. Fell on broken steps next to pumphouse.The steps are broken and when I tried to step out of the dike I fell and may have broken my leg?
1158597756 2006-08-11 Salt Water Injection Well No Violations The clean up for this facility is ablut 3/4 complete .The area to the left of the pumphouse has not been completed .There is oil and contaminated soil around the sump and the ditch that supplies it .There is not an operating flowmeter as of this inspection .
1179952965 2016-11-07 Salt Water Injection Well No Violations Injection pump was in operation today and I called well owner Mark Clark and requested that he apply positive pressure to annulus of tubing he stated that we would do mini test later this week he will call and confirm time and date.
1184843852 2009-09-24 Salt Water Injection Well No Violations Well not in operation. Dike level is good.
1185984112 2006-11-02 Salt Water Injection Well No Violations No flowmeter hooked up yet .Operator has said he would hook it up .
1211850759 2007-09-13 Salt Water Injection Well No Violations Violations are corrected.
1213231040 2006-09-06 Salt Water Injection Well No Violations The clean up of this facility is complete .There is no control head for the flow meter .Everything else is on line but it still does not work .
1231275810 2008-12-05 Salt Water Injection Well No Violations
1239i76 2001-11-1 0:00: SW No Violations 1.20
1266502906 2010-02-17 Salt Water Injection Well No Violations The well does not appear to be in production.The dike is full of snow.
1301505827 2011-02-28 Salt Water Injection Well No Violations Check this well today as part of a field training with the new Inspector Shawn Murphy. Dike is empty and well does not appear to be in operation.
1305507629 2005-09-01 Salt Water Injection Well No Violations Check to see if flow meter has been installed and found that it has not.
1308190512 2011-08-03 Salt Water Injection Well No Violations ID corrected. Pump back in operation. Clean up around dike complete.
1315352068 2019-04-14 Surface Facility Construction No Violations Inspection today revealed that injection pump was in operation during my inspection.
1319628502 2011-10-25 Salt Water Injection Well No Violations Met again with crew on clean up. Found that there has been no clean up done since 7/26/2011. There is a backhoe on site but was advised clean up would begin soon. Issued written notice and also contacted Mark Clark. Clean up is to start 10/26/2011
1320336889 2011-10-25 Salt Water Injection Well Violations Noted Check tank battery to see if any clean up of the production tanks has been done. Found crew on site but no work has been started since my last inspection. Issue written notice and send it out to cover verbal notice I issued 10/13/2011.
1320954773 2011-11-01 Salt Water Injection Well No Violations Clean up on the production side appears almost done but they have not started on the injection side clean up.
1332156825 2012-02-21 Salt Water Injection Well No Violations During my inspection today, I found the tank battery dike is mostly empty and the well not in operation.
1346634042 2009-11-23 Salt Water Injection Well No Violations Dike is mostly free of fluid.
1359651030 2007-07-03 Salt Water Injection Well No Violations FOLLOW UP TO NOV # 2119197348 Found that the barrel counter has been disconnected and is not operating as required by permit .Later I found that the well was operating over pressure and that there was clean up needed around the well head .The area around
1367270121 2013-04-29 Salt Water Injection Well No Violations Received call from well operator stating that production casing has lost integrity and he will submit repair plan to UIC section in Central Office, told him to contact local UIC inspector when plans were finalized and service rig became available to work on well.
1370784960 2013-06-06 Salt Water Injection Well No Violations Bishop Well Service on site trying to repair casing but there was no activity today at well site.
1370905124 2013-06-07 Salt Water Injection Well No Violations Omega Cementing pumped 200 sacks cement down 4.5 casing in hopes of sealing up casing, Bishop Well Service will drill out excess cement in the near future and once that stage is complete we will again try to pressure test casing to ensure we have good integrity.
1375055208 2013-07-25 Salt Water Injection Well No Violations On site to pressure test casing after Bishop Well Service drilled out cement from inside of casing after recent squeeze job we pressured up to 725 psi and monitored pressure for 15 minutes and well loss 60 psi and test failed so owner is planning on performing another cement job tomorrow and attempt to squeeze cement into zone where we are losing pressure at.
1375108268 2013-07-26 Salt Water Injection Well No Violations On site to witness squeeze job on suspected leak in casing, Omega Cementing pumped 15 sacks cement through tubing and rig crew pulled tubing and then Omega pressured up to 700 psi and we monitored pressure falloff and left pressure on well they will drill out cement on Monday 7/29/13 and then we will retest casing for integrity.
1375388306 2013-08-01 Salt Water Injection Well No Violations On site to witness casing integrity testing Bishop Well Service used there mud pump to apply pressure to casing they pumped 725# of fluid pressure and we monitored pressure too check integrity of production casing ,pressure fell off to 400# in 3 minutes and was still falling when we shut 2 valve and called company rep requesting what there next step could possibly be.
1376512806 2013-08-13 Salt Water Injection Well No Violations On site to witness Bishop Well Service run 2.875 in hole and cement it back to ground level, Omega cementing pumped 45 sacks of Class A cement and they had approximately 1 bbl of good cement returns and it stayed up good at surface.
1376570045 2013-08-15 Salt Water Injection Well No Violations On site to witness running of new 1.5 tubing and new Parmaco packer into SWIW and pump fresh water and inhibitor to pressure test annulus.

Packer set @840 and set under tension with 6 K and there is a 15 anchor joint below packer and Omega Cementing pumped 3 barrel of fresh water and inhibitor and we pressure tested annulus with 780 psi with no decline in pressure.

1378898525 2013-09-11 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and site of recent work over has been seeded and mulched and vegetation has begun to grow.
1388285147 2003-03-11 Salt Water Injection Well Violations Noted The requirements of the permit are for a flowmeter to be used to monitor barrels per day amounts . The meter has been removed and I advised Mark Clark that he must replace meter as soon as possilble . He said that he would try and locate one . 2
1390315933 2011-10-13 Salt Water Injection Well No Violations FOLLOW UP TO NOV # 471432932 Met with well crew on site and went over leaks and spills. Also went over what needs cleaned up and the repairs to be made. The production tanks need to be removed from the dike and clean up of all old oil and brine completed
1396516122 2004-03-17 Salt Water Injection Well No Violations Injection pressure-650 annulus pressure-0
1397558288 2010-11-23 Salt Water Injection Well No Violations
13975987 2002-2-15 0:00: SW No Violations 1.20
1412224023 2007-11-09 Salt Water Injection Well No Violations Barrel counter is locked
1437170432 2007-12-04 Salt Water Injection Well No Violations Found that box to the barrel counter is locked.Contact Mark Clark and he gave me the combo. Try it on the nect inspection.
1443705798 2017-07-25 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and I called well owner Mark Clark and discussed dike work needed at the site to be in compliance with SPCC rules he stated that within the next two weeks he would have dike work completed and he stated also that he is planning on changing out flowline to wellhead I told him that a pressure test would be required once line is replaced.
1463403355 2011-03-16 Salt Water Injection Well No Violations Found well in operation , gauge broke while checking pressure. Need to recheck with new gauge.
1467257015 2011-07-26 Salt Water Injection Well No Violations FOLLOW UP TO NOV # -1640707720 Met on-site with Mark Clark. Issued Compliance Notice to post correct ID and to clean up around back and in front of dike for injection well. Also addressed oil spill in the adjoining dike used for production. Mark is to p
1479152898 2016-11-14 Salt Water Injection Well No Violations On site to witness MIT testing of said well they applied 780 psi and we monitored pressure for 15 minutes with no decline.

TEST PASSED.

1483204035 2006-12-04 Salt Water Injection Well Violations Noted Had tip that a oil spill had occurred at this site .I arrived and found that there had been two spills and that there was oil inside and outside the dike .The oil and brine inside the dike are being pumped out onto the ground .Collect photos and return to New Phila office and pick up samle bottles and return to site .Met Mark Clark on site and went over clean up which needed to begin now .Had Mark disconnect the sump lines which are still pumping brine outside the dike .
1484459087 2013-08-12 Salt Water Injection Well No Violations On site to witness Bishop Well Service run 850 of good used 2.875 in well and they will cement it back to 0 tomorrow morning.
1485226404 2015-10-19 Salt Water Injection Well No Violations Inspection revealed that injection pump was not running today and owner is putting plan together to rework dike area.
1493447201 2017-04-27 Salt Water Injection Well No Violations Inpection revealed that injection pump was in operation on this day of my inspection.
1496054432 2016-10-21 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation and owner is still planning on correcting dike height to allow for volume in the event of tank failure.
1501157587 2016-08-23 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.

Note: Dike work still needs to be completed at site.

1527453881 2014-02-24 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.

Note: Stopped at company office and requested that they has positive pressure applied to annulus of tubing to ensure that they have casing integrity.

1538504595 2005-02-14 Salt Water Injection Well No Violations Met with Mark Clark and advised that a flowmeter had to be installed or I would request a Chiefs order.He said that he had one purchased that it was in the mail and that when it got here he would install it.
1542997480 2003-11-04 Salt Water Injection Well No Violations Check this well with Inspector Grimm.Found that flow meter is not connected and Met with Mark Clark and advised that meter needs to be installed. Also advised on clean up needed at production tanks on other side of facility. He said that he would clean up area soon and install flow line when he found one . I advised that he look around and see if he could find a used one.
1543359282 2016-01-26 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today.

Note: Owner still needs to complete dike improvements.

1575383640 2014-11-25 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that owner has placed a 500 bbl tank near current facility and I checked it and it was empty on this day of my inspection.
1593278957 2014-06-04 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today,
1612553324 2009-10-30 Salt Water Injection Well No Violations Check on operating status and found that well is not in operation.Dike is free of fluid
1640707720 2011-07-26 Salt Water Injection Well Violations Noted Met on-site with Mark Clark. Issued Compliance Notice to post correct ID and to clean up around back and in front of dike for injection well. Also addressed oil spill in the adjoining dike used for production. Mark is to post ID for both. He said they will remove the tanks from the production dike in order to completely clean up the old and new oil and brine inside the dike. Then clean up around the back of the tank battery and infront of the tanks for the injection well.
1642237382 2004-01-30 Salt Water Injection Well No Violations Injection pressure---280 Annulus pressure 0- Spoke with Mark Clark and advised again on installing a flow meter as part of his permit conditions.He said that he was keeping track of his water on paper and felt that he did not need a flow meter. I advised him that he did need a flow meter because he could not show a haulers record and he would have no other outside source to verify the amount of brine that he was disposing.
1652692608 2007-08-13 Salt Water Injection Well No Violations Area inside the pumphouse is flooded again so barrel counter could not be checked.
1659854007 2005-08-19 Salt Water Injection Well No Violations Check to see if flow meter has been installed and advised that one was installed and that it failed and was returned .Met with Mark Clark and he advised that one was ordered and it would be here Tues and installed by Weds.
1677296828 2007-09-13 Salt Water Injection Well No Violations Barrel counter remains working .The pressure is within limits.
1688098130 2017-11-14 Salt Water Injection Well No Violations Inspection reveled that injection pump was not in operation during my inspection.
1690359665 2014-10-06 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
1690366222 2012-06-15 Salt Water Injection Well No Violations The inside of the dike is dry at this time. The operator has promised to repair the dike and update some of this facility and wanted to wait until it is dry to complete repairs.
1703907846 2012-10-03 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today.

Note: Water build up in dike area and liner around dike needs to be covered with dirt or stone to help prevent decay due to exposure to sunlight.

1721693771 2012-08-15 Salt Water Injection Well No Violations Dike is dry during this inspection.
1764682206 2007-07-25 Salt Water Injection Well No Violations No working barrel counter at this inspection .Violation has not been corrected.
1781496097 2017-06-01 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation during my inspection.
1787178034 2013-03-04 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.

Note: Exposed portion of pit liner in tank area still needs to be covered with stone to help prevent decay due to exposure to sunlight.

18076035 2002-3-25 0:00: SW No Violations 1.20
1814978144 2009-04-13 Salt Water Injection Well No Violations This well has not been in operation since last fall .The dike is half full .
182816782 2009-6-17 0:00: SW No Violations 1.00
1843906622 2006-03-16 Salt Water Injection Well No Violations Flowmeter still not programed and is not in operation.
1845051992 2003-03-11 Salt Water Injection Well Violations Noted FOLLOW UP TO NOV # 1388285147 The requirements of the permit are for a flowmeter to be used to monitor barrels per day amounts . The meter has been removed and I advised Mark Clark that he must replace meter as soon as possilble . He said that he would
1849063663 2008-01-09 Salt Water Injection Well No Violations Flooded inside the dike area and oil and brine are on top of the dike surface.The pump is unconnected and is not in operation.Box for the barrel counter is locked.
1862711242 2015-03-03 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation today and it was noted that there was a 500 bbl tank parked at the facility and it was empty and does not appear to being used at this time.
1873354065 2008-02-20 Salt Water Injection Well No Violations Door locked on barrel counter.Well not in operation due to cold and or parts for the pump.
1886849670 2005-07-07 Salt Water Injection Well No Violations Check on status of flow meter and found that there is still no meter.Met with Mark Clark and he said that it has been ordered and that as soon as it arrives it will be installed.
1903028564 2018-01-24 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation during my inspection.

Note: Still waiting on owner to bring dike up to current standards.

1903398622 2007-04-18 Salt Water Injection Well No Violations Could not check the barrel counter today because the pumphouse is flooded and so is the dike .There is a liner in place to contain all of the fluid but I am not sure of the electrical .
1903697435 2013-10-17 Salt Water Injection Well No Violations Inspection revealed that well was not in operation during my inspection.

Note: 3-210 bbl tanks at site used for brine storage.

1910542869 2013-04-10 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that water in dike area needs to be removed to allow for volume in the event of tank failure and also exposed portion of pit liner in tank area needs to be covered with stone and positive pressure needs to be applied to annulus of tubing after valves are replaced on tubing head.
1928477715 2013-04-16 Administrative Inspection No Violations Talked to Mark Clark concerning applying positive pressure to annulus of tubing to confirm that they have casing integrity and he quoted that he would have pressure applied by mid May.
1946671777 2005-09-07 Salt Water Injection Well No Violations Check well to see if they have installed a flow meter and they have not.Met with Mark Clark and he has the flow meter, he just has not installed it.
1947189785 2010-10-15 Salt Water Injection Well No Violations Dike is dry of fluid, well does not appear to be in operation.
1963508994 2010-01-22 Salt Water Injection Well No Violations Well is not in operation .Dike has some fluid in it but is not bad. The pump is connected but does not appear to have been run for a while.
1982788968 2006-10-30 Salt Water Injection Well No Violations Check to see if flowmeter had been connected and found that it has not .Line connected but no meter .
1998071349 2008-09-08 Salt Water Injection Well No Violations Dike has some fluid in it , not enough to make it leak.Now it will need checked again to make sure that there is not a leak.
2007714522 2015-09-24 Salt Water Injection Well No Violations Inspection on this day indicated that injection pump was not in operation and we measured dike for compliance with connected volumes and we called owner telling him that dike height will need to be adjusted to become into compliance.
2043062673 2018-09-17 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.

Note: Owner is preparing to install extension to containment area as requested in previous inspections.

2049874970 2013-07-31 Salt Water Injection Well No Violations On site to witness third squeeze job on production casing Omega Cementing pumped 35 sacks Class A cement through tubing and pulled tubing from well and then applied 750 psi to casing too force cement into suspected hole in casing and they left well shut in and they plan on pressure testing the top 200 of casing in the morning.
2050463951 2011-10-26 Salt Water Injection Well No Violations Met with clean up crew and witnessed clean up of production dike. All of the contaminate soil is to be removed and taken to a landfill. Clean up should be done in a few days. Did not check well pressure.
2070568454 2014-04-16 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and I called company rep and requested that they have fresh water removed from dike area too allow for volume in the event of a major spill.
2083311480 2006-02-10 Salt Water Injection Well No Violations NO flow meter connected.
2119197348 2007-07-03 Salt Water Injection Well Violations Noted Found that the barrel counter has been disconnected and is not operating as required by permit .Later I found that the well was operating over pressure and that there was clean up needed around the well head .The area around the well needs to be limed graded and seeded along with mulch .
2124198787 2014-08-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that owner has replaced 1/4valve on annulus of tubing since my last inspection.
212490542 2010-1-25 0:00: SW No Violations 0.50
215171228 2004-9-28 0:00: SW No Violations 1.50
24254297 2009-7-28 0:00: SW No Violations 1.50
246266890 2018-3-1 0:00:0 SW No Violations
275799393 2009-6-1 0:00:0 SW No Violations 1.50
276756343 2010-3-12 0:00: SW No Violations 1.50
288768423 2006-2-6 0:00:0 SW No Violations 1.50
30919163 2016-2-1 0:00:0 SW No Violations
32376125 2002-7-8 0:00:0 SW No Violations 0.70
32876130 2002-7-2 0:00:0 SW No Violations 1.20
3351226 2009-4-17 0:00: PW No Violations 3.00
344385434 2007-8-14 0:00: SW No Violations 1.00
3855199 2020-3-5 0:00:0 SW No Violations
38776006 2002-8-20 0:00: SW No Violations 1.20
410821013 2008-5-16 0:00: SW No Violations 3.50
423019147 2008-9-4 0:00:0 SW No Violations 1.50
432841398 2010-4-13 0:00: SW No Violations 1.50
435047237 2018-6-1 0:00:0 SW No Violations
437381003 2005-8-4 0:00:0 SW No Violations 1.50
460 2002-10-16 0:00 SW No Violations 1.20
471432932 2011-10-13 0:00 SW No Violations 1.50
480767146 2003-7-10 0:00: SW No Violations 1.20
480947385 2009-4-30 0:00: SW No Violations 2.00
500221194 2013-7-24 0:00: SW No Violations
518195341 2003-9-15 0:00: SW No Violations 1.20
566963086 2006-7-12 0:00: SW No Violations 2.00
583338642 2006-7-21 0:00: SW No Violations 2.50
612957075 2008-4-18 0:00: SW No Violations 1.50
654210810 2008-6-19 0:00: SW No Violations 1.50
74392376 2006-7-18 0:00: SW No Violations 1.00
754398896 2008-5-19 0:00: SW No Violations 1.50
7675910 SW No Violations 1.20
768121421 2011-6-3 0:00:0 SW No Violations 1.50
820213871 2008-10-21 0:00 SW No Violations 1.50
827480422 2003-2-14 0:00: SW No Violations 1.50
856479832 2010-2-3 0:00:0 SW No Violations 2.50
866270377 2007-7-24 0:00: SW No Violations 1.50
868907521 2007-11-9 0:00: SW No Violations
899599439 2012-12-9 0:00: SW No Violations
906440777 2009-9-10 0:00: SW No Violations 1.50
939879655 2008-8-18 0:00: SW No Violations 2.20
996075581 2012-7-19 0:00: SW No Violations 1.50
PL2647 PL No Violations
UIC1482 1993-10-14 0:00 SW No Violations
UIC1483 1993-10-14 0:00 SW No Violations
UIC214 1987-6-10 0:00: SW No Violations
UIC215 1987-6-10 0:00: SW No Violations
UIC216 1987-6-10 0:00: SW No Violations
UIC256 1987-8-3 0:00:0 SW No Violations
UIC257 1987-8-3 0:00:0 SW No Violations
UIC810 1989-11-28 0:00 SW No Violations
UIC887 1990-4-20 0:00: SW No Violations
UIC888 1990-4-20 0:00: SW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0003351226 US-OH-123508 2009-09-01 Well operation causing pollution and contamination
0003351226 US-OH-123509 2009-09-01 Failure to keep dike or pit free of brine or other wastes
0035601521 US-OH-123744 2009-01-20 Pits not liquid tight/Improper construction or use
0217730419 US-OH-122157 2019-04-08 Failure to report disposal fees
0246266890 US-OH-122507 2018-03-27 9-3-07(D) Exceeding maximum allowable injection pressure
0410821013 US-OH-124349 2008-10-07 Pollution/Contamination
0471432932 US-OH-125120 2011-10-25 Pollution/Contamination
0477855220 US-OH-125197 2008-10-07 Pollution/Contamination
0543430886 US-OH-125958 2008-10-07 Pollution/Contamination
0566963086 US-OH-126367 2006-08-07 Mechanical failure/contamination
0654210810 US-OH-127411 2008-10-08 Pits not liquid tight/Improper construction or use
0901374467 US-OH-130290 2010-01-26 Violation of injection tubing/fitting requirements
0906440777 US-OH-130346 2009-10-07 Contamination at surface facility (permit before 6-1-82)
0939879655 US-OH-130763 2008-10-08 Pollution/Contamination
1050066161 US-OH-100823 2008-10-07 Pollution/Contamination
1095426304 US-OH-102260 2004-09-17 Failure to monitor pressures/volumes
1320336889 US-OH-109161 2011-11-03 Pollution/Contamination
1388285147 US-OH-111500 2003-03-24 Failure to monitor pressures/volumes
1483204035 US-OH-113755 2006-12-19 Pollution/Contamination
1483204035 US-OH-113756 2006-12-19 Mechanical failure/contamination
1640707720 US-OH-116147 2011-09-26 Pollution/Contamination
1845051992 US-OH-118426 2003-03-24 Failure to monitor pressures/volumes
2119197348 US-OH-121706 2007-07-11 Contamination at surface facility (permit after 6-1-82)
2119197348 US-OH-121707 2007-07-11 Exceeding maximum allowable injection pressure
2119197348 US-OH-121708 2007-07-11 Failure to monitor pressures/volumes

For data sources see[9]

References