{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.49,"lon":-81.43,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: SOUND ENERGY CO INC | |
Well Pad ID: | |
Farm/Lease Name: BICK | |
License Status: Producing | |
License Date: 2011-10-25 | |
Spud Date: 2011-11-30 | |
Spud Drilling Contractor: POULSON DRILLING | |
Final Drill Date: 2011-12-05 | |
Well Total Depth: 4953.00 ft | |
Configuration: Vertical | |
Latitude: 40.490000 | |
Longitude: -81.430000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2011-10-25 | Proposed Formations:CLINTON, Issued Date:10/25/2011, Expired Date:10/24/2013 12:00:00 PM, Drilling unit acres:47.58, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2011-12-05 | |
Construction Permit Expires | 2012-10-24 | |
Completion Report Received | 2013-01-14 | |
Record Last Modified | 2017-10-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2013-01-22 | 4753 | 4804 | 30 |
4753 | 4804 | 30 | |
4753 | 4804 | 30 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2012-01-30 | H2O | 20 | 122600 Gal | 0 | Producers Service Corporation |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | SOUND ENERGY CO INC | 500.00 | 0.00 | 31 |
2013 | SOUND ENERGY CO INC | 14313.00 | 179.00 | 365 |
2014 | SOUND ENERGY CO INC | 12516.00 | 91.00 | 365 |
2015 | SOUND ENERGY CO INC | 2871.00 | 0.00 | 365 |
2016 | SOUND ENERGY CO INC | 2578.00 | 0.00 | 365 |
2017 | SOUND ENERGY CO INC | 7935.00 | 206.00 | 365 |
2018 | SOUND ENERGY CO INC | 9673.00 | 99.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | SOUND ENERGY CO INC | Brine | 0 | 31 |
2013 | SOUND ENERGY CO INC | Brine | 97 | 365 |
2014 | SOUND ENERGY CO INC | Brine | 191 | 365 |
2015 | SOUND ENERGY CO INC | Brine | 0 | 365 |
2016 | SOUND ENERGY CO INC | Brine | 0 | 365 |
2017 | SOUND ENERGY CO INC | Brine | 30 | 365 |
2018 | SOUND ENERGY CO INC | Brine | 53 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-2092461982 | 2016-4-14 0:00: | PW | No Violations | 1.00 |
1329248041 | 2011-12-02 | Production Wells | No Violations | On location for surface job. Pits ok. |
1910740771 | 2014-05-20 | Preliminary Restoration | No Violations | On the day of my inspection accompanied by Intern Austin Gutridge, I witnessed that the production equipment included a 140bbl tank, a horizontal separator, a drip a 2 inch sales meter with a 1 inch orifice and a chart recorder. The well was capable of production and equipped with 4.5 inch casing, 1.5 inch tubing, a plunger lift system with valves open on the tubing and 1 of 2 open on the casing. 500 psi was on the casing. Identification was present and production records were up to date. The well passed preliminary restoration according to 1509.072A. |
2092461982 | 2016-04-14 | Production Wells | No Violations | In the day of my inspection I found an 8 X 4 inch wellhead, and a 4 X 1.5 wellhead operated by a plunger lift system. The valves are in the open position. The tank battery is made up of one 100 bbl. tank, a horizontal separator and a recording gauge. The tank is properly identified, the production reporting is up to date and there are no violation at this time. |