34-157-25495

Well Details

Well ID: 34-157-25495
Loading map...
Country: United States
State: Ohio
County: Tuscarawas
Municipality: Warren Township
Operator Name: EAP OHIO LLC
Well Pad ID: US-OH-000436
Farm/Lease Name: MIZER 29-15-7
License Status: Temporary Inactive Status 1st Year
License Date: 2014-11-10
Spud Date: 2014-11-19
Spud Drilling Contractor: NOMAC DRILLING CORP
Final Drill Date: 2014-12-23
Well Total Depth: 14649.00 ft
Configuration: Horizontal
Latitude: 40.540000
Longitude: -81.300000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-03-08 Proposed Formations:TRENTON - BLACK RIVER, Issued Date:3/8/2012, Expired Date:3/8/2014 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
Correction to Well 2012-03-16 CORRECTION TO Y COORDINATE.
APP 2012-06-14 Proposed Formations:POINT PLEASANT, Issued Date:6/14/2012, Expired Date:6/14/2014 12:00:00 PM, Drilling unit acres:161.2, Proposed Well Type:OG, Proposed Well Class:EDPW
Correction to Well 2012-06-15 CORRECTION TO APP TYPE, PERMIT NUMBER & CASING PROGRAM. CANCELLED STRATIGRAPHIC TEST PER OWNER REQUEST.
APP 2014-11-10 Proposed Formations:POINT PLEASANT, Issued Date:11/10/2014, Expired Date:11/9/2016 12:00:00 PM, Drilling unit acres:189.48, Proposed Well Type:OG, Proposed Well Class:EDPW
Reached Total Depth 2014-12-23
Correction to Well 2015-04-03 CHANGE IN TARGET AND TAKE-POINT INFORMATION (FOOTAGES AND COORDINATES) FROM AS DRILLED SURVEY PLAT.
Construction Permit Expires 2016-11-09
Record Last Modified 2019-05-15

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1572850713 2012-5-3 0:00:0 SC No Violations
-1694496431 2012-4-27 0:00: SC No Violations
-1853645383 2019-5-30 0:00: TI No Violations 0.70
-604284260 2016-2-22 0:00: DD No Violations 1.00
-962565826 2012-5-1 0:00:0 SC No Violations
0604284260 2016-02-22 Drill / Deepen / Reopen No Violations On the day of my inspection I found, a sign board at the access road entry featuring the well names, permit number and emergency contact information. The access road has a padlocked gate near entrance. The access road is in good repair. I found the production pad to be enclosed entirely with a chain link fence with barbed wire at the top, and with a padlocked gate. The pad has a crushed limestone surface, and is in good repair. The well is constructed with a wellhead tree of 4 inch valves. There are pipe gates protecting the well from vehicles. The cellar is full of water, and has grating covering is to prevent someone from falling in. There is no production equipment on location. I am not able to determine if the well has been frac.
0962565826 2012-05-01 Surface Facility Construction No Violations I arrived on location and found crew putting up temporary silt socks around site and removing/ stockpiling topsoil.
1336070288 2012-04-04 Surface Facility Construction No Violations I arrived on permit # 5495 to do a pre-construction permit condition inspection for a horizontal well that is going to be drilled by Chesapeake. Sent report to Steve Opritza on 04/05/12.
1411573981 2014-09-24 Not Drilled No Violations On the date of inspection I located the Chesapeake Mizer well pad. No wells have been drilled yet and the pad has vegetation covering 50% of it. Chesapeake plans to move a top hole rig in the within a month, however, the permit for this well expired in April, 2014.
1416507996 2014-11-20 Casing String Witnessed No Violations On the day of my inspection I found Rocky Mountain Drill setting 20 inch conductor pipe at 120 feet in a 26 inch hole. Universal will be cementing. Established circulation and circulated 15 bbls of good cement to surface.
1418061681 2014-12-08 Casing String Witnessed No Violations on the day of my inspection I found that the crew has drilled to the depth of 800 feet. The wire line crew is logging this section, and the are preparing to run 13 3/8 casing and cement to surface. Upon returning to location the crew was installing 13 3/8 inch casing. Schlumberger will be doing the cementing. Established circulation and circulated 34 bbls of good cement to surface
1444519826 2020-5-22 0:00: TI No Violations 1.00
1543331214 2018-11-27 Temporary Inactive Well Status No Violations Upon my arrival on location, I witnessed the access road had been maintained. The location had not been disturbed. The well was in the idle position and no production equipment was on the location. No environmental issue was visible at the time of the inspection. The location was surrounded by a chain link fence with a locked gate. The earthen dike area inside and outside of the fence, had vegetation growing on it. The monitoring gauges had been installed, but the valves were closed and locked. Therefore, the pressure gauges were reading zero. I will contact Chesapeake to unlock the monitoring valves. So, we can monitor the annular pressures. Chesapeake has applied for a Temporary Inactive Permit. The permit is presently being reviewed.
1572850713 2012-05-03 Surface Facility Construction No Violations I was called out to location by Ashley. Crew thought they dug into an old drill pit while building a new location. I talked with landowner, Glen Mizer, and he advised what crew hit was an old dump site from the 1950s and not a drill pit.
1575560466 2019-12-4 0:00: TI No Violations 0.50
1588780989 2020-5-6 0:00:0 TI No Violations 0.50
1694496431 2012-04-27 Surface Facility Construction No Violations I arrived on location and found company building location and drill pad which is approximately 365 X 500. No earthen pit will be used on this site for drilling.
1853645383 2019-05-30 Temporary Inactive Well Status No Violations This inspection is for a Temporary Inactive Well Status. Upon my arrival on location, accompanied by Southeast Supervisor Brent Bear and Gus Jerome from Encino, I witnessed the access road had been maintained. The location had not been disturbed and the sump valves were in the open position. The well was shut in and no production equipment was on the location. The monitoring gauges had been installed and the pressure gauges were showing no pressure on the annulus. No environmental issue was visible at the time of the inspection. The well cellar was full of water and we advised Encino to have the cellar pumped out. The location was surrounded by a chain link fence with locked gates. The earthen dike area inside and outside of the fence, had vegetation growing on it. We witnessed Gus Jerome completing the Inactive Status check list and signing it.

For data sources see[3]