Well ID: 34-163-20048 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.24,"lon":-82.31,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Vinton | |
Municipality: Knox Township | |
Operator Name: HOCKING HILLS ENERGY AND WELL | |
Well Pad ID: | |
Farm/Lease Name: CLINE MYRTLE | |
License Status: Dry and Abandoned | |
License Date: 2015-03-12 | |
Spud Date: | |
Spud Drilling Contractor: | |
Final Drill Date: | |
Well Total Depth: 0.00 ft | |
Configuration: Vertical | |
Latitude: 39.240000 | |
Longitude: -82.310000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1987-06-09 | 566 GRIM PAUL A |
Change of Owner | 2001-11-21 | Operator changed from 566, GRIM PAUL A to 5755, CHIEFTAIN ENERGY CORP. |
APP | 2015-03-12 | Proposed Formations:BEREA, Issued Date:3/12/2015, Expired Date:3/11/2017 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2015-10-14 | INFO. ON THIS WELL CARD REPRESENTS ALL AVAILABLE INFO. ON FILE AT THE DIV. OF GEOLOGICAL SURVEY AND THE DIV. OF OIL AND GAS., 12/31/1987. SAME AS PERMIT 20048. INSPECTED BY ANDY THOMAS 1/11/2012. |
Record Last Modified | 2017-02-17 | INFO. ON THIS WELL CARD REPRESENTS ALL AVAILABLE INFO. ON FILE AT THE DIV. OF GEOLOGICAL SURVEY AND THE DIV. OF OIL AND GAS., 12/31/1987. SAME AS PERMIT 20048. INSPECTED BY ANDY THOMAS 1/11/2012. |
Construction Permit Expires | 2017-03-11 | INFO. ON THIS WELL CARD REPRESENTS ALL AVAILABLE INFO. ON FILE AT THE DIV. OF GEOLOGICAL SURVEY AND THE DIV. OF OIL AND GAS., 12/31/1987. SAME AS PERMIT 20048. INSPECTED BY ANDY THOMAS 1/11/2012. |
For data sources see[2]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | ISON PROD SERVICES INC | 0.00 | 10.00 | 30 |
2002 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2003 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2006 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 365 |
2007 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2008 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2009 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2010 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2011 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2012 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2013 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2014 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1985 | ISON PROD SERVICES INC | Brine | 100 | 30 |
2002 | HOCKING HILLS ENERGY AND WELL | Brine | 0 | 0 |
2003 | HOCKING HILLS ENERGY AND WELL | Brine | 0 | 0 |
2006 | HOCKING HILLS ENERGY AND WELL | Brine | 0 | 365 |
2007 | HOCKING HILLS ENERGY AND WELL | Brine | 0 | 0 |
2008 | HOCKING HILLS ENERGY AND WELL | Brine | 0 | 0 |
2009 | HOCKING HILLS ENERGY AND WELL | Brine | 0 | 0 |
2010 | HOCKING HILLS ENERGY AND WELL | Brine | 0 | 0 |
2011 | HOCKING HILLS ENERGY AND WELL | Brine | 0 | 0 |
2012 | HOCKING HILLS ENERGY AND WELL | Brine | 0 | 0 |
2013 | HOCKING HILLS ENERGY AND WELL | Brine | 0 | 0 |
2014 | HOCKING HILLS ENERGY AND WELL | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1374748455 | 2013-7-16 0:00: | PW | No Violations | 1.00 |
-257971956 | 2012-1-11 0:00: | PW | No Violations | 2.00 |
-293717613 | 2015-11-25 0:00 | FR | No Violations | 2.00 |
-345921903 | 2013-7-16 0:00: | PW | No Violations | 1.50 |
-924720960 | 2015-2-5 0:00:0 | PW | No Violations | 2.00 |
0221592684 | 2015-01-21 | Production Wells | No Violations | Compliance Follow-up -257971956: The well is incapable of production. There is no identification at the well head, and there is no longer a pumping unit. The production lines have all been cut at the wellhead. There are rusted tanks and disconnected flow lines scattered about the area. There has been no resolution to any of the issues. I talked to Dave Poling with Hocking Hills Energy and explained the issues. He will work with the Vinton County Inspector, Kip Thompson, on a timeline to plug or produce the wells. |
0257971956 | 2012-01-11 | Production Wells | Violations Noted | No identification at the well head. pumping unit was present. There is no motor on the pumping unit. Flow line is in tact. Production records stated zero since 2006. Well should be plugged or placed in production. Photos were taken during inspection. |
0293717613 | 2015-11-25 | Final Restoration | No Violations | Final restoration inspection. The well has been plugged. The well site has vegetative growth. The roadway does not have vegetative growth. Flow line remains. I have spoken with well owner Doug Kitchen concerning the remainder of the restoration. He stated the flow line would be removed and the roadways seeded by 2-1-16. |
0345921903 | 2013-07-16 | Production Wells | No Violations | Status of well has not changed since last inspection. It is still idle. No attempt has been made to gain compliance. Accompanied by Inspector Kip Thompson. |
0906494030 | 2015-10-22 | Plug / Plug Back | No Violations | Equipment has been removed. Flow line has not been removed and seeding has been done. I have contacted Doug Kitchen to remind him of the need to finish the restoration |
0924720960 | 2015-02-05 | Production Wells | No Violations | Compliance notice follow-up. I met with Hocking Hills Energy supervisor Doug Kitchen at the well site. The well consists of a wellhead with rods and tubing. I informed Doug of the need to plug the well. |
1374748455 | 2013-07-16 | Production Wells | No Violations | I accompanied Andrew Thomas on this inspection, the well has not been plugged and remains idle. |
1397022623 | 2012-01-11 | Production Wells | No Violations | FOLLOW UP TO NOV # -257971956 No identification at the well head. pumping unit was present. There is no motor on the pumping unit. Flow line is in tact. Production records stated zero since 2006. Well should be plugged or placed in production. Photos were taken during inspection. |
1444764028 | 2015-10-13 | Plug / Plug Back | No Violations | Rods and tubing have been pulled. The 5 casing is free. Two joints were pulled. Formation Cementing scheduled to set bottom hole plug on 10/14/15. |
1444846578 | 2015-10-14 | Plug / Plug Back | No Violations | Hocking Hills Energy moved in and pulled the rods and tubing. They attempted to pull the 5 casing. They pulled three joints and the casing became stuck. Several attempts were made to pull the 5 casing. The casing was backed off at 510 feet. They set a 40 sack bottom hole plug, 25 sack rip plug and 63 sack surface plug. All plugs circulated. |
1834015211 | 2014-04-10 | Production Wells | No Violations | This is a follow-up inspection for the well being idle. Andy Thomas and Kip Thompson inspected this well before and wrote it up for not the well not being able to produce. The violation was issued on 1/11/2012. The well is still idle and there has been no attempt to put the well back into production. I will contact Kip Thompson and let him know about the situation. |
2139027759 | 2012-09-19 | Production Wells | No Violations | No change since last inspection. Accompanied by company representative Bill Wray. |
221592684 | 2015-1-21 0:00: | PW | No Violations | |
906494030 | 2015-10-22 0:00 | PB | No Violations | 2.00 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0257971956 | US-OH-122653 | 2012-01-18 | Failure to legibly identify well | |
0257971956 | US-OH-122654 | 2012-01-18 | Well shall be plugged | |
0257971956 | US-OH-122655 | 2012-01-18 | Nonproduction; well shall be plugged or placed in temporary inactive status |