{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.25,"lon":-82.65,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Vinton | |
Municipality: Harrison Township | |
Operator Name: COLUMBIA GAS TRANSMISSION LLC | |
Well Pad ID: | |
Farm/Lease Name: RAY LARRICK ET AL | |
License Status: Final Restoration | |
License Date: 2016-10-24 | |
Spud Date: 1958-03-15 | |
Spud Drilling Contractor: | |
Final Drill Date: 1958-04-18 | |
Well Total Depth: 2146.00 ft | |
Configuration: Vertical | |
Latitude: 39.250000 | |
Longitude: -82.650000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1958-03-15 | GL=775.1, STORAGE PROD. NAT. & I.P. BOTH READ 768 CF. |
Completed | 1958-04-18 | GL=775.1, STORAGE PROD. NAT. & I.P. BOTH READ 768 CF. |
Reached Total Depth | 1958-04-18 | GL=775.1, STORAGE PROD. NAT. & I.P. BOTH READ 768 CF. |
Change of Owner | 2011-11-30 | Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION |
APP | 2016-10-24 | Proposed Formations:CLINTON SANDSTONE, Issued Date:10/24/2016, Expired Date:10/24/2018 12:00:00 PM, Drilling unit acres:36, Proposed Well Type:SO, Proposed Well Class: |
Record Last Modified | 2017-02-10 | GL=775.1, STORAGE PROD. NAT. & I.P. BOTH READ 768 CF. |
Construction Permit Expires | 2018-10-24 | GL=775.1, STORAGE PROD. NAT. & I.P. BOTH READ 768 CF. |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
0 | 0 | 0 |
For data sources see[3]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-348404749 | 2014-10-23 0:00 | SO | No Violations | 0.10 |
0348404749 | 2014-10-23 | Storage Well | No Violations | Storage well inspection. The well has a legible identification. No violations noted. |
0692807306 | 2019-02-25 | Final Restoration | No Violations | My inspection revealed this location meets the requirement for final restoration. The well was plugged and restored in 2016. |
1298465594 | 2016-03-17 | Storage Well | No Violations | Storage well inspection. The well has a legible identification. No violations noted. |
1480963190 | 2016-12-05 | Plug / Plug Back | No Violations | Columbia gas storage well plugging inspection. The site has been prepared and the wellhead has been replaced in anticipation of the well being plugged. |
1481296032 | 2016-12-09 | Plug / Plug Back | No Violations | Kilbarger rig 15 has rigged up. Tubing has been delivered in preparation of setting the bottom hole plug on 12-12-2016. Columbia Gas has set a electric bridge plug 10 above the preformations. The tubing will have a stinger on the bottom to allow the tubing to pass thru the plug to set the bottom hole plug. |
1481556785 | 2016-12-12 | Plug / Plug Back | No Violations | Kilbarger on site, they have ran tubing down to 2100. At 2100 Columbia Gas placed a bridge plug. The tubing had a tool on the end to open the bridge plug thus allowing the cement bottom plug to set. 60 sacks of cement to set the bottom plug. The plug was set from 2124 to 1624. The plug will be tagged on 12-13-16. |
1481642965 | 2016-12-13 | Plug / Plug Back | No Violations | Baker Hughes on site at 7:30 AM. They ran a DV tool to find the free point of the 5.5 inch diameter casing. Free point was found at 1395 and the casing was shot off at 1395. Kilbarger began pulling the 5.5 inch diameter casing at 11:30 am. The next plug will be a 200 rip plug 1295 to 1495. Kilbarger attempted to pull the 7 inch diameter casing. 70,000 pounds was used in the attempt. They used a blind back off technique to remove a portion of the 7 casing. |
1481817124 | 2016-12-15 | Plug / Plug Back | No Violations | The last two plugs were finished on 12-14-16. I did not witness the lime plug or the surface plug. I did witness the Clinton plug that was placed on 12-13-16. |
1537276102 | 2018-09-18 | Storage Well | No Violations | The Columbia Gas storage well was plugged in 2016. I will contact central office to have the listed as plugged. |
1575173306 | 2012-01-04 | Storage Well | No Violations | No violations at the time of inspection. Columbia well number 9914. |
1620213293 | 2015-06-30 | Storage Well | No Violations | Storage well inspection. Legible well identification found at well. No violations found on date of inspection. |
692807306 | 2019-2-25 0:00: | FR | No Violations | 0.20 |