Well ID: 34-163-20840
Loading map...
Country: United States
State: Ohio
County: Vinton
Municipality: Knox Township
Operator Name: BANCEQUITY PETROLEUM CORPORATI
Well Pad ID:
Farm/Lease Name: STANEART CECIL
License Status: Producing
License Date: 1984-01-20
Spud Date: 1984-06-11
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 1984-06-16
Well Total Depth: 1450.00 ft
Configuration: Vertical
Latitude: 39.210000
Longitude: -82.290000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1984-01-20 Issued Date 1/20/84 Expired Date 7/18/84 Acres 0172000 Tool Type RTA Proposed Formation BEREA Proposed Depth 01450 Proposed Drill Depth 01450
Original Spud 1984-06-11 CHG. ,CSG/TOOL 6-2-84, CHG. IN FTG. 3-30-85
Completed 1984-06-16 CHG. ,CSG/TOOL 6-2-84, CHG. IN FTG. 3-30-85
Reached Total Depth 1984-06-16 CHG. ,CSG/TOOL 6-2-84, CHG. IN FTG. 3-30-85
Construction Permit Expires 1984-07-18 CHG. ,CSG/TOOL 6-2-84, CHG. IN FTG. 3-30-85
CO 1984-09-15 566 GRIM PAUL A GeoDate 1/20/84
Completion Report Received 1985-03-04 CHG. ,CSG/TOOL 6-2-84, CHG. IN FTG. 3-30-85
Change of Owner 2001-11-21 Operator changed from 566, GRIM PAUL A to 5755, CHIEFTAIN ENERGY CORP.
Change of Owner 2008-04-24 Operator changed from 5755, CHIEFTAIN ENERGY CORP to 566, GRIM PAUL A. THE TRANSFER OF THIS WELL IS PURSUANT TO JUDGEMENT ENTRY, CASE # 04-CV06-062, VINTON COUNTY COURT OF COMMON PLEAS.
Change of Owner 2009-11-17 Operator changed from 566, GRIM PAUL A to 4801, BANCEQUITY PETROLEUM CORP
Change of Owner 2009-11-18 Operator changed from 4801, BANCEQUITY PETROLEUM CORP to 566, GRIM PAUL A
Change of Owner 2009-12-22 Operator changed from 566, GRIM PAUL A to 4801, BANCEQUITY PETROLEUM CORP
Record Last Modified 2017-02-15 CHG. ,CSG/TOOL 6-2-84, CHG. IN FTG. 3-30-85

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 1265 1438 0
1265 1438 0
1265 1438 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 0 FRAC;H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 GRIM PAUL A 0.00 1215.00 365
1985 GRIM PAUL A 0.00 2010.00 365
1986 GRIM PAUL A 0.00 1812.00 365
1987 GRIM PAUL A 0.00 532.00 365
1988 GRIM PAUL A 0.00 94.00 365
1989 GRIM PAUL A 0.00 55.00 365
1990 GRIM PAUL A 0.00 0.00 365
1991 GRIM PAUL A 0.00 364.00 365
1992 GRIM PAUL A 0.00 373.00 365
1993 GRIM PAUL A 0.00 14.00 365
1994 GRIM PAUL A 0.00 538.00 365
1995 GRIM PAUL A 0.00 0.00 365
1997 GRIM PAUL A 0.00 22.00 365
1998 GRIM PAUL A 0.00 0.00 365
1999 GRIM PAUL A 0.00 0.00 365
2000 GRIM PAUL A 0.00 0.00 365
2001 GRIM PAUL A 0.00 0.00 365
2002 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2003 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2004 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2005 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2006 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2010 BANCEQUITY PETROLEUM CORPORATI 0.00 0.00 0
2011 BANCEQUITY PETROLEUM CORPORATI 207.00 335.00 0
2012 BANCEQUITY PETROLEUM CORPORATI 152.00 339.00 366
2013 BANCEQUITY PETROLEUM CORPORATI 170.00 390.00 365
2014 BANCEQUITY PETROLEUM CORPORATI 291.00 413.00 365
2015 BANCEQUITY PETROLEUM CORPORATI 343.00 332.00 365
2016 BANCEQUITY PETROLEUM CORPORATI 413.00 334.00 365
2017 BANCEQUITY PETROLEUM CORPORATI 432.00 267.00 365
2018 BANCEQUITY PETROLEUM CORPORATI 208.00 218.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 GRIM PAUL A Brine 0 365
1985 GRIM PAUL A Brine 6742 365
1986 GRIM PAUL A Brine 12322 365
1987 GRIM PAUL A Brine 4999 365
1988 GRIM PAUL A Brine 895 365
1989 GRIM PAUL A Brine 644 365
1990 GRIM PAUL A Brine 0 365
1991 GRIM PAUL A Brine 4279 365
1992 GRIM PAUL A Brine 1891 365
1993 GRIM PAUL A Brine 89 365
1994 GRIM PAUL A Brine 2098 365
1995 GRIM PAUL A Brine 0 365
1997 GRIM PAUL A Brine 88 365
1998 GRIM PAUL A Brine 0 365
1999 GRIM PAUL A Brine 0 365
2000 GRIM PAUL A Brine 0 365
2001 GRIM PAUL A Brine 0 365
2002 HOCKING HILLS ENERGY AND WELL Brine 0 0
2003 HOCKING HILLS ENERGY AND WELL Brine 0 0
2004 HOCKING HILLS ENERGY AND WELL Brine 0 0
2005 HOCKING HILLS ENERGY AND WELL Brine 0 0
2006 HOCKING HILLS ENERGY AND WELL Brine 0 0
2010 BANCEQUITY PETROLEUM CORPORATI Brine 0 0
2011 BANCEQUITY PETROLEUM CORPORATI Brine 291
2012 BANCEQUITY PETROLEUM CORPORATI Brine 625 366
2013 BANCEQUITY PETROLEUM CORPORATI Brine 798 365
2014 BANCEQUITY PETROLEUM CORPORATI Brine 1023 365
2015 BANCEQUITY PETROLEUM CORPORATI Brine 1300 365
2016 BANCEQUITY PETROLEUM CORPORATI Brine 1315 365
2017 BANCEQUITY PETROLEUM CORPORATI Brine 1333 365
2018 BANCEQUITY PETROLEUM CORPORATI Brine 1251 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1702341967 2002-3-4 0:00:0 PW No Violations
-587061634 2017-12-19 0:00 PW No Violations 0.80
0000PL2265 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
001269i832 2002-03-04 Production Wells Violations Noted An inspection of te well revealed that there is No ID at the well. Need full ID at the well and tank battery. Dike around tank battery for this well does not meet SPCC requirements, build dike to meet requirements.
001269i902 2002-03-26 Production Wells No Violations Follow-up, Non-Compliance, met with Doug Kitchen to look over violations.
01269i1007 2002-04-25 Production Wells No Violations Follo-up on NOV, Non-Compliance, company has not put ID at the well or storage tank. Called and talked to Doug Kitchen, he said he needed more time, I told him to notify Joe Hoerst in Jackson, Joe told him he had until May 3, 2002 to have all the violations corrected or court case would be filed.
01269i1013 2002-05-06 Production Wells No Violations Follow up on NOV, In-Compliance.
0587061634 2017-12-19 Production Wells No Violations On the day of this inspection, I found an oil and gas well equipped with 4.5 inch diameter casing, 1.5 inch diameter tubing and a pumping unit with an electric motor. The tank battery is shared with 8 other wells and consisted of a vertical separator, a drip and four 100 barrel steel tanks. Identification is posted at wellhead and tank battery.
1269i1007 2002-4-25 0:00: PW No Violations
1269i1013 2002-5-6 0:00:0 PW No Violations
1269i832 2002-3-4 0:00:0 PW No Violations
1269i902 2002-3-26 0:00: PW No Violations
1702341967 2002-03-04 Production Wells Violations Noted FOLLOW UP TO NOV # 1269i832 An inspection of te well revealed that there is No ID at the well. Need full ID at the well and tank battery. Dike around tank battery for this well does not meet SPCC requirements, build dike to meet requirements.
PL2265 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
001269i832 US-OH-107457 2002-03-04 Failure to legibly identify well
001269i832 US-OH-107458 2002-03-04 No SPCC dike/or failure to keep dike free of water or oil
1702341967 US-OH-116879 2002-03-04 Failure to legibly identify well
1702341967 US-OH-116880 2002-03-04 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[9]

References